Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IGNITRON CRO Search Results

    Documents mentioning IGNITRON CRO

    Document Partial File Text Tags Type PDF
    ignitron
    NATIONAL NL1057NCOAX IGNITRON CAPACITOR DISCHARGE/ELECTRONIC CROWBAR SERVICE 25,000 VOLTS 300,000 AMPERES PEAK THE NL-1057NCOAX IGNITRON IS INTENDED FOR CAPACITOR DISCHARGE USE OR FOR ELECTRONIC CROWBAR USE, AT UP TO 25 KILOVOLTS PEAK OR 300000 AMPERES PEAK.
    Original PDF
    nl7703
    NL7703 IGNITRON The 7703 ignitron is suitable for use as a switch for either capacitor discharge service or as an electronic crowbar, at peak voltages from a few hundred volts to 20 kilovolts, and peak currents up to 100 kiloamperes. GENERAL DATA Electrical:
    Original PDF
    nl7703
    NL7703LP2 IGNITRON The 7703LP2 ignitron is suitable for use as a switch for either capacitor discharge service or as an electronic crowbar, at peak voltages from a few hundred volts to 35 kilovolts, and peak currents up to 100 kiloamperes. GENERAL DATA Electrical:
    Original PDF
    nl7703ehv
    NL7703EHV IGNITRON The 7703EHV ignitron is suitable for use as a switch for either capacitor discharge service or as an electronic crowbar, at peak voltages from a few hundred volts to 50 kilovolts, and peak currents up to 100 kiloamperes. GENERAL DATA Electrical:
    Original PDF
    nl7703
    NL7703LP IGNITRON The 7703LP ignitron is suitable for use as a switch for either capacitor discharge service or as an electronic crowbar, at peak voltages from a few hundred volts to 35 kilovolts, and peak currents up to 100 kiloamperes. GENERAL DATA Electrical:
    Original PDF
    nl7703
    NL7703EHVNP IGNITRON The NL7703EHVNP ignitron is suitable for use as a switch for either capacitor discharge service or as an electronic crowbar, at peak voltages from a few hundred volts to 15 kilovolts, and peak currents up to 100 kiloamperes. The NL7703EHVNP can achieve peak voltages of up to 50kV when
    Original PDF
    nl7703h
    NL7703H IGNITRON The 7703H ignitron is suitable for use as a switch for either capacitor discharge service or as an electronic crowbar, at peak voltages from a few hundred volts to 20 kilovolts, and peak currents up to 100 kiloamperes. The 7703H incorporates an ignitor that has a resistance >125 Ohms for
    Original PDF
    PT60QHx45 PT60QHx45 Medium Voltage High Current
    PT60QHx45 PT60QHx45 Medium Voltage High Current Thyristor Switch Preliminary Information Replaces February 2000 version, DS5267-1.3 DS5267-1.4 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 1000A
    Original PDF
    pt40qpx45
    PT40QPx45 PT40QPx45 Medium Voltage High Current Thyristor Switch Preliminary Information Replaces November 1999 version, DS5267-1.1 DS5267-1.4 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 760A
    Original PDF
    pt40qpx45
    PT40QPx45 PT40QPx45 Pulse Power Thyristor Switch Preliminary Information Replaces November 1999 version, DS5267-1.1 DS5267-1.4 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 760A ITSM 13000A dI/dt
    Original PDF
    pt85qwx45
    PT85QWx45 PT85QWx45 Medium Voltage High Current Thyristor Switch Preliminary Information DS5334-1.2 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 1670A ITSM 37000A dI/dt 22000A/µs FEATURES ●
    Original PDF
    pt60qhx45
    PT60QHx45 PT60QHx45 Pulse Power Thyristor Switch Preliminary Information Replaces February 2000 version, DS5267-1.3 DS5267-1.4 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 1000A ITSM 22500A
    Original PDF
    pt85qwx45
    PT85QWx45 PT85QWx45 Pulse Power Thyristor Switch Preliminary Information DS5334-1.2 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 1670A ITSM 37000A dI/dt 22000A/µs FEATURES ● Double Side Cooling
    Original PDF
    pt85qwx45
    PT85QWx45 Pulse Power Thyristor Switch Preliminary Information DS5334-1.3 December 2008 (LN26532) KEY PARAMETERS VDRM 4500V IT(AV) 1670A ITSM 37000A dIT/dt 22000A/µs APPLICATIONS Pulse Power Crowbars Ignitron Replacement FEATURES Double Side Cooling Fast Turn-on
    Original PDF
    pt40qpx45
    PT40QPx45 PT40QPx45 Pulse Power Thyristor Switch Preliminary Information Replaces November 1999 version, DS5267-1.1 DS5267-1.4 April 2000 APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 760A ITSM 13000A dI/dt
    Original PDF
    pt40qpx45
    PT40QPx45 PT40QPx45 Pulse Power Thyristor Switch Preliminary Information DS5267-2 July 2014 ( LN31779) APPLICATIONS ● Pulse Power ● Crowbars ● Ignitron Replacement KEY PARAMETERS 4500V VDRM IT(AV) 760A ITSM 13000A dI/dt 5000A/µs FEATURES ● Double Side Cooling
    Original PDF
    ignitron
    /V/L /g05 A 7 m( NL-1057 ~INI CAPACITOR DISCHARGE/ELECTRONIC CROWBAR SERVICE 25,000 VOLTS 600,000 AMPERES PEAK THE NL-1057 IGNITRON IS INTENDED FOR CAPACITOR DISCHARGE USE OR FOR ELECTRONIC CROWBAR USE, AT UP TO 25 KILOVOLTS PEAK, OR 600,000 AMPERES PEAK.
    Original PDF
    ignitron
    /VL-/#Ar A ~~~~~HIGH VIOLTAGE NATIONAL _ _ _ _ _ SWITCHING I GNI T RONS _____ National Electronics, Inc. High Voltage Switching Ignitrons are used in a variety of applications including capacitor discharge, clamping, and crowbar. Each application has its own particular switching requirement
    Original PDF
    dynex
    Pulsed Power www.dynexsemi.com 1 Pulsed Power Pulsed Power Pulsed Power can be defined as electrical energy that is delivered as single or repeated pulses of relatively short duration such that the peak power delivered is high but the average power is low.
    Original PDF