IGNITION TRANSFORM Search Results
IGNITION TRANSFORM Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TUSS4440TRTJT | Texas Instruments | Transformer drive ultrasonic sensor IC with logarithmic amplifier |
|
|
|
| ISO1176TDW | Texas Instruments | Isolated ProfiBus Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
|
|
|
| ISO3086TDWR | Texas Instruments | Isolated 485 Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
|
|
|
| ISO1176TDWR | Texas Instruments | Isolated ProfiBus Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
|
|
|
| ISO3086TDW | Texas Instruments | Isolated 485 Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
|
|
Documents mentioning IGNITION TRANSFORM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| s8610u | S8610U Universal Intermittent Pilot Gas Ignition Control SUPER TRADELINE® INSTALLATION INSTRUCTIONS APPLICATION ® The SUPER TRADELINE S8610U Universal Intermittent Pilot Gas Ignition Control Module is designed to provide easy field replacement of a wide range of |
Original | ||||
| burner | High Voltage Transformers Ignition Unit Type: Japan SPT Ignition unit for gas stove tops ■ Features ● For 1 to 4 pilot burner gas stove tops ● DC input: 1.5 V/3.0 V ● Efficient generation of HV with good load performance ● High vacuum potting with nonflammable epoxy |
Original | ||||
| High Voltage Transformers Ignition Unit Type: | High Voltage Transformers Ignition Unit Type: Japan SPT Ignition unit for gas table Industrial Property: Patents 8 (pending) ■ Features ● For 1 to 4 pilot burner gas table ● DC input: 1.5 V/3.0 V ● Efficient generation of HV with good load performance by adopting unique winding system |
Original | ||||
| an819 | AN819 APPLICATION NOTE CAPACITIVE DISCHARGE IGNITION INTRODUCTION In the world of small motor, such as mopeds or lawn movers the ignition system design is based exclusively on CDI (1). In automobile CDI was in the past only used in the replacement module market. Today, |
Original | ||||
| sidac | Teccor® brand Thyristors Multipulse™ SIDACs Kxxx1G Series Description The Multipulse™ SIDAC is a voltage switch used in MetalHalide lamp ignition circuits as well as High Pressure Sodium lamp ignition circuits for outdoor street and area lighting. This robust solid state switch is designed to handle |
Original | ||||
| Teccor® brand Thyristors Multipulse™ SIDACs | Teccor® brand Thyristors Multipulse™ SIDACs Kxxx1GL Series RoHS Description The Multipulse™ SIDAC is a voltage switch used in MetalHalide lamp ignition circuits, as well as High Pressure Sodium lamp ignition circuits for outdoor street and area lighting. This robust solid-state switch is designed to handle |
Original | ||||
| Teccor® brand Thyristors Multipulse™ SIDACs | Teccor® brand Thyristors Multipulse™ SIDACs Kxxx1G Series Description The Multipulse™ SIDAC is a voltage switch used in MetalHalide lamp ignition circuits as well as High Pressure Sodium lamp ignition circuits for outdoor street and area lighting. This robust solid state switch is designed to handle |
Original | ||||
| hgt1s14n41g3vls | HGT1S14N41G3VLS, HGTP14N41G3VL Data Sheet September 2000 14A, 410V N-Channel, Logic Level, Voltage Clamping IGBTs Title This N-Channel IGBT is a MOS gated, logic level device GT1 which is intended to be used as an ignition coil driver in 4N4 automotive ignition circuits. Unique features include an |
Original | ||||
| Teccor® brand Thyristors Multipulse™ SIDACs | Teccor® brand Thyristors Multipulse™ SIDACs Kxxx1G Series Description The Multipulse™ SIDAC is a voltage switch used in MetalHalide lamp ignition circuits as well as High Pressure Sodium lamp ignition circuits for outdoor street and area lighting. This robust solid state switch is designed to handle |
Original | ||||
| capacitive discharge ignition | APPLICATION NOTE CAPACITIVE DISCHARGE IGNITION A. BREMOND P. MERCERON 1. INTRODUCTION 2. CDI PRINCIPE In the world of small motor, such as mopeds or lawn movers the ignition system design is based exclusively on CDI (1). In automobile CDI was in the past only used in the replacement module market. Today, due to new standards of pollution control, the CDI system is becoming one of the most |
Original | ||||
| ignition transformer | IGNITION TRANSFORMERS Spark-Line - 233mH - 375mH Compact Design Available up to 23kV Ambient Temperature 70°C Weight: 0.018kg Packaging unit: 70 pieces Primary Resistance (±10%) Secondary Resistance (±10%) Primary Inductance (±15%) Secondary Inductance |
Original | ||||
| ignition transformer | IGNITION TRANSFORMERS Spark-Line - 233mH - 375mH Compact Design Available up to 23kV Ambient Temperature 70°C Weight: 0.018kg Packaging unit: 55 pieces (tray) Primary Resistance (±10%) Secondary Resistance (±10%) Primary Inductance (±15%) Secondary Inductance |
Original | ||||
| IGNITION TRANSFORMERS Spark-Line - 233mH - 375mH | IGNITION TRANSFORMERS Spark-Line - 233mH - 375mH Compact Design Available up to 23kV Ambient Temperature 70°C Weight: 0.018kg Packaging unit: 55 pieces (tray) Primary Resistance (±10%) Secondary Resistance (±10%) Primary Inductance (±15%) Secondary Inductance |
Original | ||||
| ignition transformer | IGNITION TRANSFORMERS Spark-Line - Secondary External (2x) Compact Design Available up to 23kV Ambient Temperature 70°C Weight: 0.018kg Packaging unit: 45 pieces Part Number 1 Primary Resistance (±10%) Secondary Resistance (±10%) Primary Inductance (±15%) |
Original | ||||
|
|
||||||
| ignition transformer | IGNITION TRANSFORMERS Spark-Line - Secondary External (1x) Compact Design Available up to 22kV Ambient Temperature 70°C Weight: 0.019kg Packaging unit: 45 pieces (tray) Part Number 125-0032.0 Primary Resistance (±10%) Secondary Resistance (±10%) Primary |
Original | ||||
| ignition transformer | IGNITION TRANSFORMERS Spark-Line - Secondary External (1x) Compact Design Available up to 22kV Ambient Temperature 70°C Weight: 0.019kg Packaging unit: 45 pieces Part Number 125-0032.0 Primary Resistance (±10%) Secondary Resistance (±10%) Primary Inductance |
Original | ||||
| ignition transformer | IGNITION TRANSFORMERS Spark-Line - Secondary External (2x) Compact Design Available up to 23kV Ambient Temperature 70°C Weight: 0.018kg Packaging unit: 45 pieces (tray) Part Number 1 Primary Resistance (±10%) Secondary Resistance (±10%) Primary Inductance |
Original | ||||
| power semiconductor applications philips semiconductors | Automotive Power Semiconductor Applications Philips Semiconductors CHAPTER 5 Automotive Power Electronics 5.1 Automotive Motor Control (including selection guides) 5.2 Automotive Lamp Control (including selection guides) 5.3 The TOPFET 5.4 Automotive Ignition |
Original | ||||