    iepe accelerometers
    Practical considerations in using IEPE accelerometers with modern data acquisition systems TP 326 cmyk Practical considerations in using IEPE accelerometers with modern data acquisition systems For many years, sensor manufacturers have offered high quality
    Original PDF
    Model 805 Accelerometer TO-5 Series Accelerometer
    Model 805 Accelerometer TO-5 Series Accelerometer 2-Wire IEPE Interface Low-Cost, Embedded Applications Wide Bandwidth to 15kHz The Model 805 is a miniature adhesive mount IEPE accelerometer built on a 3-pin TO-5 header. It is available in ±50g and ±500g
    Original PDF
    Model CAACS Commercial Automated Accelerometer
    Model CAACS Commercial Automated Accelerometer Calibration System Features > Vibration calibration 0.5 Hz to 40 kHz > Shock calibration 20 g to 10,000 g > Calibration of different type of transducers, PE, IEPE, PR, VC, Servo, Velocity > Calibration certificates may be customized by user
    Original PDF
    scxi-1530
    SCXI Accelerometer Input SCXI Accelerometer Input Modules NI SCXI-1530, NI SCXI-1531 • Programmable gain per channel (1,10,100) • Programmable lowpass 4-pole Bessel filter per channel (2.5, 5, 10 and 20 kHz) • 4 mA current source, 24 V compliance • IEPE conditioning – software
    Original PDF
    iepe
    Isotron and charge mode piezoelectric accelerometers, pros and cons TP 320 Isotron and charge mode piezoelectric accelerometers, pros and cons Should one use a high impedance PE type charge mode accelerometer, or one with internal electronics (IEPE)? This is one
    Original PDF
    iepe
    Model 4999 16 Channel low-pass filter signal conditioner Features Description • 16-channel 7 position 4 or 6-pole selectable low-pass cutoff frequencies. • Constant current supply/amplifier for Isotron®/IEPE compatible accelerometers, voltage sensors and
    Original PDF
    vibration sensor
    Vibration Sensor Guide NI Vibration Sensor Suite NEW! ◾◾ IEPE excitation ◾◾ Calibrated ◾◾ Multiple form factors ◾◾ Various sensitivities ◾◾ Tested to work with NI dynamic signal acquisition (DSA) products Overview The NI Vibration Sensor Suite is a group of sensors NI offers individually that
    Original PDF
    iepe
    Model 2793 ISOTRON® signal conditioner Features Description • 16-channel constant current supply/ amplifier for ISOTRON®/IEPE compatible accelerometers or remote charge convertors • “D” output connector for simple connection to D/A board • Wide frequency range: 1 Hz to 80 kHz
    Original PDF
    ni 4472
    24-Bit, 102.4 kS/s, 8- and 4-Channel Dynamic Signal Acquisition NI 4472 Series, NI PCI-4474 • 24-bit resolution • 110 dB dynamic range • 102.4 kS/s maximum sampling rate • 45 kHz alias-free bandwidth • ±10 V range • AC/DC coupling • IEPE conditioning –
    Original PDF
    Practical considerations of accelerometer noise
    Practical considerations of accelerometer noise cmyk Practical considerations of accelerometer noise By Bruce B. Lent March 2007 This paper is written as an overview on low-noise piezoelectric accelerometers and will review when and where low-noise devices are needed as well as the engineering tradeoffs made
    Original PDF
    accelerometers
    Steps to selecting the right accelerometer Steps to selecting the right accelerometer At first look, an accelerometer manufacturer’s catalog or web site can be intimidating to both the novice and often the more experienced user. Accelerometers are offered in a variety of
    Original PDF
    accelerometer
    Steps to selecting the right accelerometer TP 327 Steps to selecting the right accelerometer At first look, an accelerometer manufacturer’s catalog or web site can be intimidating to both the novice and often the more experienced user. Accelerometers are offered in a variety of
    Original PDF
    9233
    Sound and Vibration Data Acquisition NI 9233, NI 9234 NEW! • 24-bit resolution 102 dB dynamic range 4 simultaneous analog inputs ±5 V input range Antialiasing filters TEDS read/write Supported in NI CompactDAQ, CompactRIO, and Hi-Speed USB carrier
    Original PDF
    9234
    Sound and Vibration Data Acquisition NI 9233, NI 9234 NEW! • Supported Hardware Platforms 24-bit resolution 102 dB dynamic range 4 simultaneous analog inputs ±5 V input range Antialiasing filters TEDS read/write • NI CompactDAQ
    Original PDF
    e1432
    PDFINFO H7 1 9 3 - 0 1 16-Channel 51.2 kSa/sec Digitizer Plus DSP HP E1432A Technical Specifications ● On-board DSP improves total system performance Built-in signal conditioning simplifies tests and reduces cost Sample rates from 51.2 kHz to 25.6 Hz (per
    Original PDF
    e1433
    PDFINFO H1 5 9 3 - 0 1 8-Channel 196 kSa/sec Digitizer plus DSP HP E1433A Technical Specifications ● On-board DSP offloads complex signal processing Built-in signal conditioning simplifies tests and reduces cost Anti-alias protection from 0.057 Hz to 88 kHz
    Original PDF
    A high temperature 100 mV/g triaxial
    A high temperature 100 mV/g triaxial accelerometer Endevco® technical paper 329 A high temperature 100 mV/g triaxial accelerometer Introduction of the signal conditioning module is provided by a hightemperature coaxial cable and connectors. A separation The need for reliable, high performing and low cost
    Original PDF
    usb-4432
    Sound and Vibration Data Acquisition NI USB-4432 NEW! • 24-bit resolution 101 dB dynamic range 5 simultaneous analog inputs ±40 V input range Antialiasing filters TEDS read/write Software-selectable AC/DC coupling (0.1 Hz HPF) Recommended Software
    Original PDF
    picoscope
    100-2012:QuarkCatalogTempNew 8/14/12 7:32 AM Page 100 INTERCONNECT TEST & MEASUREMENT 1 PC Based Precision Oscilloscopes and Spectrum Analyzers Precision Oscilloscopes PicoScope precision oscilloscopes feature 12-bit and 16-bit vertical resolution and are accurate to 1% or better — Making them ideal for high accuracy signal measurement.
    Original PDF
    pxi-449x
    Sound and Vibration Data Acquisition NI PXI-449x, NI PXIe-449x NEW! 16 simultaneous analog inputs 24-bit resolution 204.8 kS/s maximum sampling rate 114 dB dynamic range +10, +20, and +30 dB gains ±0.316, 1, 3.16, and 10 V input ranges Antialiasing filters
    Original PDF
    ni usb-4431
    Sound and Vibration Data Acquisition NI USB-4431 NEW! • One 24-bit analog output Four 24-bit simultaneous analog inputs ±3.5 V output range ±10 V input range 100 dB dynamic range Antialiasing filters TEDS read/write Software-selectable AC/DC
    Original PDF
    09 Winter 2009 Product resource cmyk Sensing
    09 Winter 2009 Product resource cmyk Sensing history Market solutions 04 Piezoresistive accelerometers 14 Variable capacitance accelerometers 16 Piezoresistive pressure sensors 18 Piezoelectric accelerometers 20 Isotron® accelerometers 24 Electronic signal conditioners and amplifiers
    Original PDF
    1440-dyn02-01rj
    XM Dynamic Measurement Module User Manual Catalog Number 1440-DYN02-01RJ Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local