Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    HSD PLUG Search Results

    HSD PLUG Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CN-ACPRREDAA0
    Amphenol Cables on Demand RCA Male Plug Cable Connector (Red) - Amphenol ACPR-RED - Gold Plated Diecast Shell PDF
    MP-5FRJ11SLPS-002
    Amphenol Cables on Demand Amphenol MP-5FRJ11SLPS-002 Flat Silver Satin Modular Phone Cable Cable - RJ11 Plug to 4-Conductor Spade Lugs 2ft PDF
    MP-5FRJ11UNNS-001
    Amphenol Cables on Demand Amphenol MP-5FRJ11UNNS-001 Flat Silver Satin Modular Cables Plug to Tinned End, RJ11 (4 conductors) 1ft PDF
    MP-5FRJ12UNNS-002
    Amphenol Cables on Demand Amphenol MP-5FRJ12UNNS-002 Flat Silver Satin Modular Cables Plug to Tinned End, RJ12 (6 conductor) 2ft PDF
    MP-5FRJ11SLPS-007
    Amphenol Cables on Demand Amphenol MP-5FRJ11SLPS-007 Flat Silver Satin Modular Phone Cable Cable - RJ11 Plug to 4-Conductor Spade Lugs 7ft PDF

    HSD PLUG Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    VTAC 4

    Contextual Info: VTAC HSD USER’S MANUAL TABLE OF CONTENTS SECTION 1 VTAC HSD PART IDENTIFICATION SECTION 2 VTAC HSD INSERT INSTALLATION/REMOVAL INSTRUCTIONS SECTION 3 VTAC HSD RAILS INSTALLATION/REMOVAL INSTRUCTIONS SECTION 4 VTAC HSD 90 SERIES MODULES INSTALLATION/REMOVAL INSTRUCTIONS


    Original
    vtac 4 PDF

    Automotive HSD Connector

    Abstract: LVDS connector GVIF
    Contextual Info: ingun Prüfmittelbau GmbH Max-Stromeyer-Straße 162 78467 Konstanz Germany Product Information Tel. +49 7531 8105-0 Fax +49 7531 8105-65 info@ingun.com www.ingun.com HFS-819 Contacting of HSD Plug Connectors HSD Plug Connectors are used to transfer High-Speed Data HSD


    Original
    hfs-819automotive hsd connectorlvds connector gvif PDF

    Contextual Info: VPC’s VTAC High Speed Data HSD connectors allow engineers in multiple industries to test devices that communicate at greater speeds and require higher data rates. The VTAC HSD insert features a data transfer rate of 12.5+ Gbps per differential pair. Each VTAC HSD 50 µ" gold-plated, self-aligning contact


    Original
    PDF

    interface HSD Rosenberger

    Abstract: ROSENBERGER* HSD 99K10D-1D5A5-Y IEC/ROSENBERGER* HSD
    Contextual Info: TECHNICAL DATA SHEET HSD 99K10D-1D5A5-Y STRAIGHT JACK All dimensions are in mm; tolerances according to ISO 2768 m-H Interface RF-connector RN_065-01 Documents RF_35/11.05/3.1 Assembly instruction Pinning instruction HSD: MA_D4V007 RN 053-01 Rosenberger Hochfrequenztechnik GmbH & Co. KG


    Original
    99k10d-1d5a5-yd4v007d-84526interface hsd rosenberger+2rosenberger* hsdiec/rosenberger* hsd PDF

    D4S10A-400L5-Z

    Abstract: ROSENBERGER hsd ISO 2768-mH tolerances sheet D4S10A-400L5-D D4S10A-400L5 D4S10A- 400L5- Y mb pcb D4S10A-400L5-Y ISO 2768-mH
    Contextual Info: TECHNICAL DATA SHEET HSD STRAIGHT PLUG FOR PCB D4S10A-400L5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s10a-400l5-yd4v0126t/66d-84526+10rosenber-400l5-ed4s10a-400l5-fd4s10a-400l5-zrosenberger hsdiso 2768-mh tolerances sheetd4s10a-400l5-dd4s10a-400l5d4s10a- 400l5- ymb pcbiso 2768-mh PDF

    D4S10A-40ML5-Z

    Abstract: D4S10A-40ML5 D4S10A-40ML5-Y
    Contextual Info: TECHNICAL DATA SHEET HSD STRAIGHT PLUG FOR PCB D4S10A-40ML5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s10a-40ml5-yd4v0166t/66d-84526+418-40ml5-ed4s10a-40ml5-fd4s10a-40ml5-zd4s10a-40ml5 PDF

    D4S10A-400L5-Z

    Abstract: D4S10A-400L5 PA6T66 ROSENBERGER hsd D4S10A-400L5-E
    Contextual Info: TECHNICAL DATA SHEET HSD STRAIGHT PLUG FOR PCB D4S10A-400L5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s10a-400l5-yd4v0126t/66d-84526+6d4s10a-400l5-fd4s10a-400l5-zd4s10a-400l5pa6t66rosenberger hsdd4s10a-400l5-e PDF

    99S20D-40MA5-A

    Abstract: ROSENBERGER hsd 99S20D-40MA5-Z ROSENBERGER* HSD mb 562 MB310 99S20D-40MA5-B
    Contextual Info: TECHNICAL DATA SHEET HSD 99S20D-40MA5-Y RIGHT ANGLE PLUG PCB All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface RF-Connector


    Original
    99s20d-40ma5-yvg14799s20d-40ma5-zd-84526+699s20d-40ma5-arosenberger hsdrosenberger* hsdmb 562mb31099s20d-40ma5-b PDF

    interface HSD Rosenberger

    Abstract: 99S20D-40MA5-Y MQS 4 99S20D-40MA5-B ROSENBERGER hsd USCAR-2 thermal shock RN_053-01 mqs plug MB310 99S20D40MA5D
    Contextual Info: TECHNICAL DATA SHEET HSD 99S20D-40MA5-Y RIGHT ANGLE PLUG PCB All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface RF-Connector


    Original
    99s20d-40ma5-yvg14799s20d-40ma5-dd-84526+9interface hsd rosenbergermqs 499s20d-40ma5-brosenberger hsduscar-2 thermal shockrn_053-01mqs plugmb31099s20d40ma5d PDF

    D4S10E-40MA5-D

    Abstract: D4S10E-40MA5-Y 40MA5 ROSENBERGER hsd D4S10E D4S10E-40MA5 DIN IEC 60068-2-27 ROSENBERGER* HSD VG160 D4S10E-40MA5-C
    Contextual Info: TECHNICAL DATA SHEET HSD D4S10E-40MA5-Y STRAIGHT PLUG FOR PCB All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s10e-40ma5-yvg160d4s10e-40ma5-fd4s10e-40ma5-z+9d-84526d4s10e-40ma5-d40ma5rosenberger hsdd4s10ed4s10e-40ma5din iec 60068-2-27rosenberger* hsdd4s10e-40ma5-c PDF

    99S2UI-40MA5-Y

    Contextual Info: TECHNICAL DATA SHEET HSD 99S2UI-40MA5-Y RIGHT ANGLE PLUG PCB All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface RF-Connector


    Original
    99s2ui-40ma5-yvg156d-84526 PDF

    Contextual Info: TECHNICAL DATA SHEET HSD 99S20I-40MA5-Y RIGHT ANGLE PLUG PCB All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface RF-Connector


    Original
    99s20i-40ma5-yvg146d-84526 PDF

    ROSENBERGER hsd

    Abstract: 99S20D-40MA5-Z ISO 2768-mH tolerances sheet interface HSD Rosenberger hsd 500 1 MB310 ROSENBERGER* HSD 99S20D-40MA5 99S20D-40MA5-B 99S20D-40MA5-D
    Contextual Info: TECHNICAL DATA SHEET HSD 99S20D-40MA5-Y RIGHT ANGLE PLUG PCB All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface RF-Connector


    Original
    99s20d-40ma5-y12sim99s20d-40ma5-zd-84526+9rosenberger hsdiso 2768-mh tolerances sheetinterface hsd rosenbergerhsd 500 1mb310rosenberger* hsd99s20d-40ma599s20d-40ma5-b99s20d-40ma5-d PDF

    ROSENBERGER hsd

    Abstract: interface HSD Rosenberger ROSENBERGER* HSD DIN IEC 60068-2-27 s358 Rohs PA6T66 D4S12H-40MA5-C 40mA-5 M250V D4S12H-40MA5-B
    Contextual Info: TECHNICAL DATA SHEET HSD STRAIGHT PLUG FOR PCB D4S12H-40MA5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s12h-40ma5-yd4v0166t/66d4s12h-40ma5-f+13d4s12h-40ma5-z11-s358d-84526rosenberger hsdinterface hsd rosenbergerrosenberger* hsddin iec 60068-2-27s358 rohspa6t66d4s12h-40ma5-c40ma-5m250vd4s12h-40ma5-b PDF

    D4S20G-400A5-Z

    Abstract: ROSENBERGER hsd D4S20G-400A5-C D4S20G-400A5-D D4S20G-400A5-Y D4S20G-400A5-A D4S20G-400A5-F 05901 MB261 D4S20G-400A5
    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20G-400A5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20g-400a5-yd4v013d-845260g-400a5-e+10d4s20g-400a5-fd4s20g-400a5-z08-s463rosenberger hsdd4s20g-400a5-cd4s20g-400a5-dd4s20g-400a5-a05901mb261d4s20g-400a5 PDF

    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20Y-40MA5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20y-40ma5-yd4v019d-8452611-s505 PDF

    D4S10A-40ML5-Z

    Abstract: D4S10A-40ML5-Y D4S10A-40ML5 D4S10A-40ML5-A ROSENBERGER hsd D4S10A40ML5Z D4S10A- 40ML5- Y D4S10A-40ML5-B
    Contextual Info: TECHNICAL DATA SHEET HSD STRAIGHT PLUG FOR PCB D4S10A-40ML5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s10a-40ml5-yd4v0166t/66d-84526+8d4s10a-40ml5-fd4s10a-40ml5-zd4s10a-40ml5d4s10a-40ml5-arosenberger hsdd4s10a40ml5zd4s10a- 40ml5- yd4s10a-40ml5-b PDF

    D4S20D-40ML5-Y

    Abstract: D4S20D-40ML5-Z ROSENBERGER hsd interface HSD Rosenberger D4S20D-40ML5-H D4S20D-40ML5-F D4S20D-40ML5-D D4S20D-40ML5-B D4S20D-40ML5-E D4S20D
    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20D-40ML5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20d-40ml5-yd4v0106t/66d-84526+10d4s20d-40ml5-hd4s20d-40ml5-jd4s20d-40ml5-zrosenberger hsdinterface hsd rosenbergerd4s20d-40ml5-fd4s20d-40ml5-dd4s20d-40ml5-bd4s20d-40ml5-ed4s20d PDF

    ROSENBERGER* HSD

    Abstract: MB261 ROSENBERGER HSD plug Z ROSENBERGER hsd
    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20H-40MA5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20h-40ma5-yd4v018d-84526d4s20h-40ma5-d+7d4s20h-40ma5-ed4s20h-40ma5-fd4s20h-40ma5-zrosenberger* hsdmb261rosenberger hsd plug zrosenberger hsd PDF

    D4S2UD

    Abstract: D4S2UD-40ML5-Y D4S2UD-40ML5-H ROSENBERGER hsd D4S2UD-40ML5-L D4S2UD-40ML5-O D4S2UD-40ML5-M DIN IEC 60068-2-27 D4S2UD-40ML5-K
    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S2UD-40ML5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s2ud-40ml5-yd4v0106t/66d-84526+9d4s2ud-40ml5-kd4s2ud-40ml5-ld4s2ud-40ml5-md4s2ud-40ml5-o08-s525d4s2udd4s2ud-40ml5-hrosenberger hsddin iec 60068-2-27 PDF

    ROSENBERGER* HSD

    Abstract: 40mA-5A 6t66 VG127 DIN IEC 60068-2-27 ROSENBERGER hsd
    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20H-40MA5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20h-40ma5-yd4v018vg1276t/66+9rs20h-40ma5-ed4s20h-40ma5-fd4s20h-40ma5-zd-84526rosenberger* hsd40ma-5a6t66din iec 60068-2-27rosenberger hsd PDF

    D4S21J-40MA5-Y

    Abstract: interface HSD Rosenberger D4S21J-40MA5-B ROSENBERGER* HSD 250VRMS 40MA5-B
    Contextual Info: TECHNICAL DATA SHEET HSD TWIN RIGHT ANGLE PLUG FOR PCB D4S21J-40MA5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMC-screening. Interface


    Original
    d4s21j-40ma5-yd4v02710t/xhochfrequenztechn21j-40ma5-a+10d4s21j-40ma5-dd4s21j-40ma5-fd4s21j-40ma5-z10-v795d-84526interface hsd rosenbergerd4s21j-40ma5-brosenberger* hsd250vrms40ma5-b PDF

    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20Y-400A5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20y-400a5-yd-84526 PDF

    D4S20L-40MA5-C

    Abstract: 40MA5 D4S20L-40MA5-E D4S20L-40MA5-B D4S20L-40MA5-A ROSENBERGER hsd D4S20L-40MA5-F D4S20L-40MA5-Y D4S20L-40MA5-D 40mA-5
    Contextual Info: TECHNICAL DATA SHEET HSD RIGHT ANGLE PLUG FOR PCB D4S20L-40MA5-Y All dimensions are in mm; tolerances according to ISO 2768 m-H EMC-screening must be assured by chassis compartment. Control box manufacturer is responsible for EMCscreening. Interface According to


    Original
    d4s20l-40ma5-yd4v010pa6t/66d-84526+11d4s20l-40ma5-hd4s20l-40ma5-jd4s20l-40ma5-c40ma5d4s20l-40ma5-ed4s20l-40ma5-bd4s20l-40ma5-arosenberger hsdd4s20l-40ma5-fd4s20l-40ma5-d40ma-5 PDF