HRC FUSE 3ND Search Results
HRC FUSE 3ND Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCKE800NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B | Datasheet | ||
| TCKE800NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B | Datasheet | ||
| TCKE805NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE805NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE812NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet |
Documents mentioning HRC FUSE 3ND
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 3ra13 | 3RA13, 3RA14 Contactor Assemblies 3RA14 Contactor Assemblies for Wye-Delta Starting 3RA14 complete units, 3… 75 kW ■ Function 3 Wye-delta starting can only be used either if the motor normally operates in a D connection or starts softly or if the load torque |
Original | ||||
| overload relay | 3UA Thermally Delayed Overload Relays CLASS 10 Technical data according to IEC 947-4 Type 3UA70 11/ 3UA70 21 Trip class CLASS 10A (2 s < tA ≤10 s at 7.2 ×Ie from cold state and tA ≤2 min at 1.5 ×Ie from hot state) Phase failure sensitivity by differential phase shift |
Original | ||||
| © Siemens AG 2007 17 SENTRON Switching and | © Siemens AG 2007 17 SENTRON Switching and Protection Devices – Switch Disconnectors 17/4 17/8 17/10 17/13 17/16 17/17 17/18 17/19 17/21 17/24 17/26 17/29 Introduction 3KA, 3KE, 3LD Switch Disconnectors 3KA, 3KE Switch Disconnectors up to 1000 A General data |
Original | ||||
| simocode | SIMOCODE 3UF Motor Management and Control Devices SIMOCODE-DP 3UF5 motor protection and control devices ■ Technical specifications Shared data of basic unit/expansion unit/ expansion module/operator panel Permissible ambient temperature °C -25… +60 Permissible storage temperature |
Original | ||||
| SIRIUS Datasheet 2009 Low Voltage Controls & | SIRIUS Datasheet 2009 Low Voltage Controls & Distribution Answers for industry. s Pressing, equipping, transporting. These functions run in many automated production environments. You’ll find everything that you need to switch, protect and start motors with the extensive portfolio of the modular SIRIUS system. |
Original | ||||
| © Siemens AG 2013 Switching Devices – Contactors | © Siemens AG 2013 Switching Devices – Contactors and Contactor Assemblies – for Switching Motors 3/2 3/6 3/13 3/40 3/64 3/65 3/91 3/96 3/112 3/117 3/127 3/135 3/145 3/150 3/158 3/164 3/173 3/180 3/181 3/183 3/184 3/188 3/193 Introduction Power contactors |
Original |