Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    high accuracy pressure indicator circuit diagram Datasheets

    Top Results (6)

    Part ECAD Model Manufacturer Description Download Buy
    BD18362EFV-M ROHM Semiconductor Automotive Dynamic Indicator Lamps 8ch Matrix LED Controller Visit ROHM Semiconductor
    BD00FC0WFP ROHM Semiconductor 1A Variable Output, High-Accuracy LDO Regulator Visit ROHM Semiconductor
    BD50FA1MG-M ROHM Semiconductor 100mA 5V, Fixed Output, High-Accuracy LDO Regulator for Automotive Visit ROHM Semiconductor
    BD50FD0WHFP ROHM Semiconductor 2A 5V, Fixed Output, High-Accuracy LDO Regulator Visit ROHM Semiconductor
    BD50C0AWFP-C ROHM Semiconductor 35V Voltage Resistance 1A, High-Accuracy LDO Regulator for Automotive Visit ROHM Semiconductor
    BD33HC5WEFJ ROHM Semiconductor 1.5A 3.3V, Fixed Output, High-Accuracy LDO Regulator Visit ROHM Semiconductor

    high accuracy pressure indicator circuit diagram Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    symbol oil pressure sensor

    Abstract: 12v dc 240v ac inverter 12v to 240v inverter circuit water differential pressure sensor liquid level sensor capacitive 12v AC to DC CIRCUIT DIAGRAM for led tube lights high pressure sensor circuit air pressure sensor tube oil pressure sensor atmospheric pressure sensor circuit
    Text: PRESSURE SENSORS DP-M I/O CIRCUIT AND WIRING DIAGRAMS DP-M2 Standard type I/O circuit diagram , LED Digital Display High Accuracy & Resolution PE LED Bar Display DP-M Marked Conforming to EMC Directive High Accuracy and Resolution Bright Display · Easy Key Operation Pressure Unit Selectable Due to differential pressure sensing, the pressure can be set with a high , , morover, the detection accuracy is within 1% F.S. Three bright red 7-segment LEDs, 12mm high , are


    Original
    PDF

    10K80A

    Abstract: DN100 PN16 NE43 PN40 JIS-10K-100A JIS-10K-80A CISPR-16 FCX dp cell difference between 304, 316 and 316L
    Text: 500kPa{5bar} high differential pressure range. 0.1% accuracy is available as option. Fuji , operating pressure Optional features A plug-in analog indicator (1.5% accuracy ) can be housed in the , high temperature and highly corrosive process conditions. FEATURES 1. High accuracy 0.2% accuracy , construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit , the 13th digit code "H", "J", "S", "T", "K".) 21 High accuracy type Low


    Original
    PDF 32kPa 500kPa 10K80A DN100 PN16 NE43 PN40 JIS-10K-100A JIS-10K-80A CISPR-16 FCX dp cell difference between 304, 316 and 316L

    Not Available

    Abstract: No abstract text available
    Text: Other Products DP-100 DP-M High accuracy & resolution High accuracy and resolution Due to differential pressure sensing, the pressure can be set with a high resolution of 0.01 kPa.D {1 mmH2O.D} over a pressure range of 0 to 2.00 kPa.D {0 to 204 mmH2O.D} and, moreover, the detection accuracy is , measurement, the pressure unit can be recognized at a glance from the pressure unit indicator . kPa , Sensor DP-M SERIES 686 I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram FIBER SENSORS


    Original
    PDF DP-100

    JIS-10K-100A

    Abstract: DN100 PN16 KB910 NE43 JIS-10K G5121 Diaphragm Pressure Gauge
    Text: . FEATURES 1. High accuracy 0.2% accuracy for all calibrated spans is a standard feature for all GP models covering 1.3kPa{0.013bar} range to 50000kPa{500bar} high pressure range. 0.1% accuracy is available as , circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level , for zero and span adjustment. Indicator : A plug-in analog indicator (1.5% accuracy ) can be , stainless steel/304 stainless steel (6th digit code "5") High accuracy type Low


    Original
    PDF 013bar} 50000kPa 500bar} JIS-10K-100A DN100 PN16 KB910 NE43 JIS-10K G5121 Diaphragm Pressure Gauge

    ASTM A194 2H

    Abstract: ASTM nut and bolt ASTM A193 EN61326-1 NE43 SCS13 material SCS14A date sheet of 10th class bolts M10 scs14a equivalent
    Text: 3000kPa {30bar} high pressure range. 0.1% accuracy is available as option. Fuji's micro-capacitance , to provide exceptional performance and functionality. FEATURES 1. High accuracy 0.2% accuracy , Indicator : A plug-in analog indicator (2.5% accuracy ) An optional 5-digit LCD meter with engineering , stainless steel nut (*4) High accuracy type (*7) Instruction manual attached Opposite Vent/Drain Plug Position Instruction manual attached Instruction manual unattached High accuracy


    Original
    PDF 016bar} 3000kPa 30bar} 694mH ASTM A194 2H ASTM nut and bolt ASTM A193 EN61326-1 NE43 SCS13 material SCS14A date sheet of 10th class bolts M10 scs14a equivalent

    water level indicator using 7 segment display

    Abstract: sunx dp 20 TDK noise FILTER water level controller using timer 555 P806 diode T P806 sensor using 555 timer eddy current Sensor SUNX DP2 7 segment digital display
    Text: diameter of rings High accuracy eddy current type displacement sensor Analog fiber sensor , transistor Applicable SUNX sensors Input range Model No. 4 to 20mA CA2-T1 High accuracy eddy , CONTROLLERS CA2 55g approx. 779 I/O CIRCUIT AND WIRING DIAGRAMS Input circuit diagram , ) Users' circuit Output circuit diagram Notes: 1) COM. (0V) is internally connected to GND. Notes , 8mm 65.5mm 20mA 50MPa 48mm Conversion 4mA Displayed value ( pressure ) 24mm


    Original
    PDF W48H24D65 50MPa PS-18V ZCAT3035-1330 water level indicator using 7 segment display sunx dp 20 TDK noise FILTER water level controller using timer 555 P806 diode T P806 sensor using 555 timer eddy current Sensor SUNX DP2 7 segment digital display

    liquid filling circuit diagram

    Abstract: high accuracy pressure indicator circuit diagram pressure indicator transmitter for gas LDN900AP LDN900DP LDN900DR LDN900FG LDN900YF
    Text: . Characteristics Connection High accuracy Please connect in accordance with the following diagram , don't , circuit which transforms pressure signals into 4 20mA 2-wires industrial standard signal. Excellent packing technique ensured their high quality and fine performance. LDN900 series pressure transmitters , pressure MPa Accuracy 14;32;52 ±0.25% 14 ±0.25% 1.RangeS The range of the transmitter , min range Damping: time constant "cn" continuously adjustable between 0.2~1.67 Indicator accuracy


    Original
    PDF LDN900 M10X1 liquid filling circuit diagram high accuracy pressure indicator circuit diagram pressure indicator transmitter for gas LDN900AP LDN900DP LDN900DR LDN900FG LDN900YF

    DC-12

    Abstract: DC-13 EN50081-2 EN50082-2 005KP
    Text: conductors PRESSURE SENSOR DP-M I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Wiring , SERIES Differential Pressure · High Precision Finely Precise Digital Pressure Controller , Operation Pressure Unit Selectable With the differential pressure measurement by the accuracy of , for your convenience either "kPa" or "mmH2O". The pressure unit indicator notifies you which unit , threshold value (M1) Upper threshold value (M2) High pressure level 0 Upper threshold


    Original
    PDF 01kPa 00kPa 204mm M38mm DC-12 DC-13 EN50081-2 EN50082-2 005KP

    1998 - pdcr 910

    Abstract: DRUCK pdcr 910 druck pdcr 250 PDCR 910 series PDCR 910 druck PTX 1400 PDCR 810 pdcr druck sensor PTX1400 Ex97D2058
    Text: 646-729 646-735 646-741 646-757 Panel mounting digital pressure indicator DPI 260 (RS stock no. 646-763) The digital pressure indicator will measure and indicate pressure to an accuracy of ±0.1% full scale. The indicator utilises the PDCR 810 or 820 series pressure transducers. The compact, self contained , ) q 16 pressure units q Leak testing q High accuracy (0.1% full scale) q Ambient temperature , accuracy Zero and span adjustment of +/-5% Absolute and Gauge referenced pressure ranges 4 to 20mA output


    Original
    PDF ca075% pdcr 910 DRUCK pdcr 910 druck pdcr 250 PDCR 910 series PDCR 910 druck PTX 1400 PDCR 810 pdcr druck sensor PTX1400 Ex97D2058

    JIS-10K-100A

    Abstract: JIS-10K-80A JIS10K-80A JIS-20K-80A level sensor transmitter JIS-30K-80A flange jpi 150 DN100 PN16 zero elevation and zero suppression G5121
    Text: performance and functionality. FEATURES 1. High accuracy 0.2% accuracy for all calibrated spans is a standard feature for all models covering 0.32kPa{3.2mbar} range to 500kPa{5bar} high differential pressure , electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal , extension of diaphragm Optional features Indicator : A plug-in analog indicator (1.5% accuracy ) can , stainless steel nut High accuracy type Low temperature effect type H+J Note Note 6


    Original
    PDF 32kPa 500kPa 7/16-20UNF depth10 JIS-10K-100A JIS-10K-80A JIS10K-80A JIS-20K-80A level sensor transmitter JIS-30K-80A flange jpi 150 DN100 PN16 zero elevation and zero suppression G5121

    fkc fuji

    Abstract: 22J 1KV ASTM nut and bolt 33J 4KV G5121 MR-01-75 NE43 teflon gasket ASTM A193 bolts M10
    Text: and functionality. FEATURES 1. High accuracy ±0.07% 0.07% accuracy is a standard feature. Fuji , ) and high performance electronics circuit (Electronics unit), reliability of dry calibration without , Indicator : A plug-in analog indicator (1.5% accuracy ) can be housed in the electronics compartment or in , Press.conn. ( High pressure side) 4-M8 12 Conduit conn. D E F 4th digit of the code symbols , . (Low pressure side) Press.conn. ( High pressure side) 4-M8 12 10 1/4-18NPT 54 70 104


    Original
    PDF

    water level mpx5050

    Abstract: bio-medical temperature sensor MPX 1,45 psi mpx7000 biomedical pressure sensor oil pressure sensor MPX5050 series pressure sensors MPX200A biomedical pressure sensor 300mmhg MPX200a application
    Text: pressure Input and ratiometric with supply voltage. High sensitivity and excellent long-term repeatability , architecture with integrated circuit technology to offer a wide range of pressure sensing devices for , Flow Indicator Oil Pressure Sensor Air Flow Indicators Anti-Start Breathalizer Systems Smart Suspension , Mini Selector Guide Pressure Sensors Part# MPX10 Series MPX50 Series MPX100 Series MPX200 Series , max Max Pressure Rating 1.45 psi 7.3 psi 14.5 psi 29 psi 100 psi 0.87 psi Packages 4 pin -


    OCR Scan
    PDF MPX10 MPX50 MPX100 MPX200 MPX700 MPX906 MPX2010 MPXT2010G MPX2050 MPX2100 water level mpx5050 bio-medical temperature sensor MPX 1,45 psi mpx7000 biomedical pressure sensor oil pressure sensor MPX5050 series pressure sensors MPX200A biomedical pressure sensor 300mmhg MPX200a application

    Not Available

    Abstract: No abstract text available
    Text: Analog fiber sensor High accuracy eddy current type displacement sensor LED collimated beam sensor , . Users’ circuit * 1 Output circuit diagram Non-voltage contact or NPN open-collector transistor , PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS , threshold level even if there is a change in the reference pressure . So the threshold level does not need , level OK? NG Reference pressure increase Before reference pressure change Application NG


    Original
    PDF

    JIS-10K-50A

    Abstract: JIS-30K-50A JIS-10K-40A JIS-10K-50A flange size JIS-20K-50A flange size JIS-20K-40A JIS-30K-40A JIS10K G5121 JPI-300LB-1
    Text: of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit , Optional features Indicator : A plug-in analog indicator (1.5% accuracy ) can be housed in the , stainless steel nut High accuracy type Low temperature effect type H+J Note 2: (*2 , specifications Service: Liquid, gas, or vapour Static pressure , span, and range limit: Static pressure , influence The "Advanced Floating Cell" design which protects the pressure sensor against changes in


    Original
    PDF 7/16-20UNF JIS-10K-50A JIS-30K-50A JIS-10K-40A JIS-10K-50A flange size JIS-20K-50A flange size JIS-20K-40A JIS-30K-40A JIS10K G5121 JPI-300LB-1

    ASTM A194 2H

    Abstract: ASTM A193 ASTM nut and bolt CISPR16-2 NE43 G5121 MR-01-75 SCS14 1450377PSI NACE
    Text: 3000kPa{30bar} high pressure range. 0.1% accuracy is available as option. Fuji's micro-capacitance , to provide exceptional performance and functionality. FEATURES 1. High accuracy 0.2% accuracy , /drain A plug-in analog indicator (1.5% accuracy ) can be housed in the electronics compartment or in , stainless steel nut High accuracy type F KA 0 9 10 11 12 13 14 15 21 4 , ABSOLUTE PRESSURE TRANSMITTER FKA.4 DATA SHEET The FCX ­ A2 absolute pressure transmitter


    Original
    PDF 016bar} 3000kPa 30bar} ASTM A194 2H ASTM A193 ASTM nut and bolt CISPR16-2 NE43 G5121 MR-01-75 SCS14 1450377PSI NACE

    ASTM A194 4l

    Abstract: ASTM A194 2H ASTM nut and bolt FKG4 ASTM Bolt M12 G5121 MR-01-75 NE43 UP5840 DIN19213
    Text: performance and functionality. FEATURES 1. High accuracy ±0.07% 0.07% accuracy is a standard feature , pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high , plug-in analog indicator (1.5% accuracy ) can be housed in the electronics compartment or in the terminal , PRESSURE TRANSMITTER FKG.4 DATA SHEET The FCX ­ A2 pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique


    Original
    PDF 7/16-20UNF depth10 ASTM A194 4l ASTM A194 2H ASTM nut and bolt FKG4 ASTM Bolt M12 G5121 MR-01-75 NE43 UP5840 DIN19213

    Not Available

    Abstract: No abstract text available
    Text: accurately output since it incorporates a high accuracy linearity correction circuit . ENVIRONMENTAL , washer. GP-A SERIES High Accuracy Eddy Current Type Displacement Sensor 1038 I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Wiring diagram 47 Ω 47 Ω 5 D1 D2 7 8 +V , 1035 FIBER SENSORS High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES Related , Maximum distance Shift adjustment range: ±0.5 V 0V Maximum distance High Accuracy Eddy Current


    Original
    PDF

    2001 - 1kva inverter circuit diagram

    Abstract: 2kva inverter circuit diagram AIR FLOW DETECTOR FULL REPORT automatic phase changer file 220V Automatic Voltage Regulator schematic 48v to 220v inverter schematic diagram automatic phase changer toshiba tosgage 7511 X-RAY thickness 24V to 220V inverter schematic diagram
    Text: Pipe connection PT3/4 or PT1 Circuit diagram P. no. Model no. Connection port dia. Switch , -7525 is a high quality thickness gage for cold rolling achieving outstanding safety, operability, accuracy and cost-performance developed over many years. It has the following features. · Noise immunity , dryer Cooling water supply unit Oil mist separator Flow rate gage (for cooling water) Pressure switch (for air) Pressure switch (for nitrogen) Valve stand Interface (for PI/O interface with


    Original
    PDF OSGAGE-7525 EJD-069 OSGAGE-7525. 1kva inverter circuit diagram 2kva inverter circuit diagram AIR FLOW DETECTOR FULL REPORT automatic phase changer file 220V Automatic Voltage Regulator schematic 48v to 220v inverter schematic diagram automatic phase changer toshiba tosgage 7511 X-RAY thickness 24V to 220V inverter schematic diagram

    DIODE T25-4

    Abstract: RT-911-15 PX1-DM3N human presence detection sensors circuit LX12N NA40-B photoelectric sensor circuit diagram circuit diagram water level INFRARED sensor Optical proximity sensor through beam laser triangulation
    Text: wavelength, various colors can be detected as the difference in optical intensity. High accuracy detection · Advanced optical system and electronic circuit technology have achieved a sensing accuracy of up , -12N) · Small object detectable with high accuracy · No beam alignment needed · Space saving (FZ , detectable with high accuracy · No beam alignment needed · Space saving · Wiring only on one side · Not , Pressure Sensors TYPES OF SENSORS 4 Classification by output circuit NO Load NC (Some models


    Original
    PDF 100/ND300 LX12N DIODE T25-4 RT-911-15 PX1-DM3N human presence detection sensors circuit LX12N NA40-B photoelectric sensor circuit diagram circuit diagram water level INFRARED sensor Optical proximity sensor through beam laser triangulation

    S45C NUT

    Abstract: Y131 Yamatake float transmitter SLX110 SCS13A hydrometer liquid level indicator instruments bolt with nut ss SCS16A S45C
    Text: assembly. This will be a certified product under High Pressure Gas Law. If the connecting size is JIS10K , liquid level instrument manufacture as certified by Minister for high pressure gas types: 1)-1 Title of , ) (Standard, without indicator ) (for high temperature, with indicator ) (for high temperature, without indicator ) Bolt / nut (refer to table 2) Gasket (Standard) (for high temperature) (with indicator , indicator ) (Standard, without indicator ) (for high temperature, with indicator ) (for high temperature


    Original
    PDF SS2-SLX100-0100 S45C NUT Y131 Yamatake float transmitter SLX110 SCS13A hydrometer liquid level indicator instruments bolt with nut ss SCS16A S45C

    namur ne43

    Abstract: 500mmHg EN61326-1 MR-01-75 NE43 D701 66kPa
    Text: provide exceptional performance and functionality. FEATURES 1. High accuracy ±0.1% 0.1% accuracy is a standard feature. Fuji's micro-capacitance silicon sensor assures this accuracy for all elevated or , ACCESSORIES Indicator : A plug-in turnable analog indicator (2.5% accuracy ) An optional 5digits LCD , PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) FKP.5 DATA SHEET The FCX­ AIII pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20mA signal. The transmitter utilizes


    Original
    PDF 694mH namur ne43 500mmHg EN61326-1 MR-01-75 NE43 D701 66kPa

    2005 - JIS-10K-50A

    Abstract: JIS-10K-40A JIS-10K-50A flange size JIS-30K-50A JIS-20K-50A flange size JIS-20K-40A JIS-30K-40A material SCS14A JIS-20K-50A JIS-10
    Text: parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry , analog indicator (2.5% accuracy ) can be housed in the electronics compartment or in the terminal box of , stainless steel bolt / 304 stainless steel nut (*4) Note 4 High accuracy type Instruction , Instruction manual unattached High accuracy type Instruction manual unattached Low temperature effect type , environmental influence The "Advanced Floating Cell" design which protects the pressure sensor against changes


    Original
    PDF ANSI/JPI-300LB-1 ANSI/JPI-300LB-2B JIS-10K-50A JIS-10K-40A JIS-10K-50A flange size JIS-30K-50A JIS-20K-50A flange size JIS-20K-40A JIS-30K-40A material SCS14A JIS-20K-50A JIS-10

    E105 tantalum

    Abstract: ASTM A194 2H fuji H R C M F 2J 225 ASTM nut and bolt EDS6-128 EN61326-1 G5121 MR-01-75 NE43 ASTM Bolt M12
    Text: 1kPa=10mbar=101.9716mmH2O =4.01463inH2O Load limitations: see figure below [] 2000 Load resistance 1. High accuracy , of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit , Indicator : A plug-in analog indicator (2.5% accuracy ) An optional 5-digit LCD meter with engineering , ) (*4) High accuracy type (*11) Instruction manual attached Opposite Vent/Drain Plug , PRESSURE TRANSMITTER FKG.5 DATA SHEET The FCX ­ AIII pressure transmitter accurately


    Original
    PDF 694mH E105 tantalum ASTM A194 2H fuji H R C M F 2J 225 ASTM nut and bolt EDS6-128 EN61326-1 G5121 MR-01-75 NE43 ASTM Bolt M12

    JIS-10K-100A

    Abstract: JIS-10K-80A JIS10K-80A namur ne43 CI384 JIS-10K JIS-30K-80A EN61326-1 NE43 10K100A
    Text: 1. High accuracy 0.2% accuracy for all calibrated spans is a standard feature for all GP models covering 1.3kPa {0.013bar} range to 50000kPa {500bar} high pressure range. 0.1% accuracy is available as , circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level , Indicator : A plug-in analog indicator (2.5% accuracy ). An optional 5-digit LCD meter with engineering , (*10) High accuracy type Instruction manual attached Low temperature effect type


    Original
    PDF 013bar} 50000kPa 500bar} 694mH JIS-10K-100A JIS-10K-80A JIS10K-80A namur ne43 CI384 JIS-10K JIS-30K-80A EN61326-1 NE43 10K100A

    JIS-10K-20A

    Abstract: JIS-10K-15A JIS-10K-50A JIS-10K-50A flange size JIS-30K-50A JIS-20K-20A JIS-10K-40A JPI300LB 10K15A NE43
    Text: performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure , SMALL FLANGE REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER FKX.4 DATA SHEET The FCX­A2 small flange remote seal type differential pressure transmitter accurately measures differential pressure , liquid level or gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter , assures excellent reliability in high temperature and highly corrosive process conditions. FEATURES 1


    Original
    PDF 1/2-14NPT 3/4-14NPT JIS-10K-20A JIS-10K-15A JIS-10K-50A JIS-10K-50A flange size JIS-30K-50A JIS-20K-20A JIS-10K-40A JPI300LB 10K15A NE43
    ...
    Supplyframe Tracking Pixel