    TCTH022BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function Datasheet
    TCTH021BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type Datasheet
    COMBOSENSOR
    Texas Instruments XTR117 XTR117 4-20mA Current Loop Transmitter Visit Texas Instruments
    COMBOBODYSENSOR
    Texas Instruments ADS1292 Complete Low Power Integrated Analog Front End for ECG Applications Visit Texas Instruments
    PKGS-25SXAP1-R
    Murata Manufacturing Co Ltd Shock Sensor PDF

    HELIUM SENSOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    8525 Series Hermetic Connectors

    Abstract: EN3646 Souriau 8525 contact AS3582029 AS3582-025 souriau 8525/en3646
    Contextual Info: 8525 Series Hermetic Connectors Hermetic and Small Bayonet Connectors EN3646 Standard Qualified Combination of pressure robustness and compacity. For sensors and space constrained applications. High pressure performance Glass to metal sealing. Helium leakage of less than 10-7 atm.cm3/s.


    Original
    en3646he30ermetic8525 series hermetic connectorssouriau 8525 contact+3as3582029as3582-025souriau 8525/en3646 PDF

    helium sensor

    Abstract: H2O2 gas sensor Silicon Microstructures SM5310 Exar cross SM5300 SM5320 fs100c fs100a
    Contextual Info: SM5320 Standard Pressure SMT Helium Compatible SILICON MICROSTRUCTURES DIVISION October 1997-1 DESCRIPTION The SM5320 Pressure Sensor is the lat­ est addition to the SM5300 Series of pressure sensors in surface mountable packages. This product is similar to the


    OCR Scan
    sm5320sm5300sm5310helium sensor+5h2o2 gas sensorsilicon microstructuresexar crossfs100cfs100a PDF

    EN3646

    Abstract: 22B41 Souriau 8525 contact souriau en3646 connector 8525 Souriau 22B21 EN2997 souriau 8525 Souriau 8525 series connector 8525
    Contextual Info: 8525 Series Hermetic Connectors Hermetic and Small Bayonet Connectors EN3646 Standard Qualified Combination of pressure robustness and compacity. For sensors and space constrained applications. High pressure performance Glass to metal sealing. Helium leakage of less than 10-7 atm.cm3/s.


    Original
    en3646wmae8525hp04101en22b41souriau 8525 contact+7souriau en3646connector 8525 souriau22b21en2997souriau 8525souriau 8525 seriesconnector 8525 PDF

    EN3646

    Contextual Info: 8525 Series Hermetic Connectors Hermetic and Small Bayonet Connectors EN3646 Standard Qualified Combination of pressure robustness and compacity. For sensors and space constrained applications. High pressure performance Glass to metal sealing. Helium leakage of less than 10-7 atm.cm3/s.


    Original
    en3646wmae8525hp04103en PDF

    Contextual Info: SM5320 Standard Pressure SMT Helium Compatible SILICON MICROSTRUCTURES DIVISION O ctober 1997-1 DESCRIPTION The SM5320 Pressure Sensor is the lat­ est addition to the SM5300 Series of pressure sensors in surface mountable packages. This product is similar to the


    OCR Scan
    sm5320sm5300sm5310 PDF

    PX2151-250GI

    Contextual Info: ULTRA HIGH PURITY PRESSURE TRANSDUCERS MADE IN FOR HIGH PURITY SYSTEMS NIST USA PX2150 Series 4-20 mA Output 625 625 ߜ Electropolished VAR 316L SS Wetted Parts ߜ Assured 0.25% Accuracy ߜ Helium Leak Tested to 1x10-9 ATM.CC/sec ߜ NIST Traceable Calibration


    Original
    px21501x10-9px2151-v050gidp41-e+4dp25-edp-7700px2151-v100gipx2151-250gi PDF

    Contextual Info: ULTRA HIGH PURITY PRESSURE TRANSDUCERS MADE IN USA PX2150 Series 5 Volt Output Series $PX2150 5 Volt Output $ 625 625 PX2150-100G5V $625 ߜ Electropolished VAR 316L SS Wetted Parts ߜ Assured 0.25% Accuracy ߜ Helium Leak Tested to 1x10-9 ATM.CC/sec Shown Smaller Than


    Original
    px2150px2150-100g5v1x10-9signalx2150-v050g5v+3px2150-v100g5vpx2150-v250g5vpx2150-050g5v PDF

    Contextual Info: Series 99 Ultra-high leak integrity media resistant soleniod valves FEATURES • 2-way and 3-way configurations · Performs at high speed opening response time ≤ 5 ms · Leak-tight to 1 x 10-8 cm3/s/atm Helium · Provides ultra-high vacuum and high pressure


    Original
    PDF

    soleniod

    Contextual Info: Series 9 High-performance media resistant soleniod valves FEATURES • 2-way and 3-way configurations · Performs at high speed opening response time ≤ 5 ms · Leak-tight to 1 x 10-7 cm3/s/atm Helium · Configurable up to 1250 psi · Offers repeatability and consistency


    Original
    soleniod PDF

    Contextual Info: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors - Note # 3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temper­ ature sensing resistor located on either side of the heater. The


    OCR Scan
    PDF

    helium sensor

    Abstract: AWM42150VH nitrogen gas sensor hydrogen and carbon monoxide gas sensor nitric oxide gas sensor gas sensor helium types methane gas sensor gas sensor no2 Transistor A131 helium gas sensor
    Contextual Info: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The


    Original
    helium sensorawm42150vhnitrogen gas sensorhydrogen and carbon monoxide gas sensor+6nitric oxide gas sensorgas sensor heliumtypes methane gas sensorgas sensor no2transistor a131helium gas sensor PDF

    Contextual Info: GAS CONVERSION FACTORS For FMA-5600, FMA-5700 and FMA-8500 Flow Sensors The FMA-5600, FMA-700/800 , and FMA-8500 Electronic Mass Flowmeters and Controllers are factory calibrated for nitrogen, N2 . However, these units can be used for many gases, with the


    Original
    fma-5600fma-5700fma-8500fma-700/800+2c4h10fma-8506 PDF

    helium sensor

    Contextual Info: SM5320 Surface Mo unt ab le Pressure Sensor <K*i«$w:ny Description The SM5320 Pressure Sensor is the latest addition to the SM5300 Series ot pressure sensors in surface mountable packages. This product is similar to the SM5310 pressure sensor except that a


    OCR Scan
    sm5320sm5300sm5310helium sensor PDF

    helium sensor

    Abstract: "Flow Sensor" AWM42000 hydrogen gas sensor AWM42150VH nh3 sensor gas sensor helium gas sensor no2 AWM42150VH application nitric oxide sensor
    Contextual Info: AWM42000 Series Mass flow sensor for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/o-ring sealed SERVICE To be used with dry gases only. The AWM42150VH is a special sensor for


    Original
    awm42000awm42150vhawm42300vhelium sensor+7flow sensorhydrogen gas sensornh3 sensorgas sensor heliumgas sensor no2awm42150vh applicationnitric oxide sensor PDF

    AWM43000

    Abstract: hydrogen gas sensor AWM43300V "Flow Sensor" hydrogen sensor helium sensor AWM43600V ch4 sensor methane carbon dioxide sensor nitrogen dioxide sensor
    Contextual Info: AWM43000 Series Mass flow sensor for gases FEATURES • Ranges 0.1000 sccm1 and 0.6 slpm2 · Actual mass flow sensing · 1.5 V output · Manifold mount/o-ring sealed SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through


    Original
    awm43000awm43300vawm43600vawm43300vh+7hydrogen gas sensorflow sensorhydrogen sensorhelium sensorch4 sensormethane carbon dioxide sensornitrogen dioxide sensor PDF

    FDUH002DB

    Abstract: Flow Sensors hydrogen gas sensor helium gas sensor "Flow Sensor" FDUM200DB CO2 SENSOR sensortechnics flow sensor
    Contextual Info: FDU Series Mass flow sensors for gases FEATURES • Ranges 0.±200 sccm1 or 0.±2 "H2O 0.±5 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only


    Original
    fduh002dbflow sensorshydrogen gas sensorhelium gas sensor+4flow sensorfdum200dbco2 sensorsensortechnics flow sensor PDF

    FHAL200DU

    Abstract: "Flow Sensor" gas sensors airflow sensors liquid flow sensor medical Flow Sensor fhal200
    Contextual Info: FHA Series Mass flow sensors for gases FEATURES • Ranges 0.200 slpm1 · Actual mass flow sensing · 1.5 V output · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FHA series is NOT designed for liquid flow and will be damaged by liquid flow through


    Original
    fhal200duflow sensorgas sensorsairflow sensors+3liquid flow sensormedical flow sensorfhal200 PDF

    "Flow Sensor"

    Abstract: helium sensor AWM2100V AWM2200V AWM2000 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH
    Contextual Info: AWM2000 Series Mass flow sensor for gases FEATURES • Ranges 0.±30 to 0.±1000 sccm1 or 0.±4 "H2O 0.±10 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid


    Original
    awm2000gas11awm2150vawm2100v+7awm2100vhawm2300vawm2300vhawm2200vflow sensorhelium sensor6 pin gas sensor PDF

    "Flow Sensor"

    Abstract: helium sensor hydrogen gas sensor AWM90000 AWM92100V AWM92200V CO2 SENSOR liquid density sensor nitrous oxide sensor gas sensor CO
    Contextual Info: AWM90000 Series Mass flow sensor for gases FEATURES • Ranges 0.±200 sccm1 or 0.±2 "H2O 0.±5 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid


    Original
    awm90000awm92100vawm92200vflow sensor+6helium sensorhydrogen gas sensorco2 sensorliquid density sensornitrous oxide sensorgas sensor co PDF

    "Flow Sensor"

    Abstract: Flow Sensors FMOM025HB NO2 sensor SensorTechnics mass flow
    Contextual Info: FMO Series Mass flow sensors for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only.


    Original
    fmom025hbflow sensorflow sensorsno2 sensor+1sensortechnics mass flow PDF

    "Flow Sensor"

    Abstract: FMAL001D
    Contextual Info: FMA Series Mass flow sensors for gases FEATURES • Ranges 0.1000 sccm1 and 0.6 slpm2 · Actual mass flow sensing · 1.5 V output · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FMA series is NOT designed for liquid


    Original
    fmal001dufmal006duflow sensorfmal001d PDF

    AWM3000

    Abstract: "Flow Sensor" AWM3303V helium sensor AWM3100V AWM3201CR nitric oxide gas sensor nitric oxide sensor AWM3150V AWM3200CR
    Contextual Info: AWM3000 Series Mass flow sensor for gases FEATURES • Ranges 0.30 to 0.±1000 sccm1 or 0.0.5 to 0.2 "H2O 0.1.25 to 0.5 mbar · 1.5 V, 1.3.75 V, 4.20 mA output · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only


    Original
    awm3000awm3303vawm3150vawm3100v+8awm3300vawm3201crawm3200vawm3200crflow sensorhelium sensornitric oxide gas sensornitric oxide sensor PDF

    helium sensor

    Abstract: Flow Sensors hydrogen gas sensor FBOL001DB "Flow Sensor" types methane gas sensor filter fbo 500
    Contextual Info: FBO Series Mass flow sensors for gases FEATURES • Ranges 0.±30 to 0.±1000 or -600.1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FBO series is NOT designed for


    Original
    helium sensorflow sensorshydrogen gas sensorfbol001db+3flow sensortypes methane gas sensorfilter fbo 500 PDF

    FBAM200DU

    Abstract: Flow Sensors "Flow Sensor" FBAL001 SensorTechnics flow
    Contextual Info: FBA Series Mass flow sensors for gases FEATURES • Ranges 0.30 to 0.±1000 sccm1 · 1.5 V or 1.3.75 V output · Actual mass flow sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FBA series is NOT designed for liquid


    Original
    fbal001dbfbam200duflow sensorsflow sensor+2fbal001sensortechnics flow PDF