Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    HEAT FLOW SENSOR Search Results

    HEAT FLOW SENSOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCTH022BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function Datasheet
    TCTH021BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type Datasheet
    UE36C1620005D6A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 21.5mm high fin pin style heat sink, front to back air flow PDF
    UE36C1650005A3A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 6.5mm height fin pin style heat sink, front to back air flow PDF
    UE36-C26200-05C3A
    Amphenol Communications Solutions 1x2 QSFP-DD cage with SAN height fin pin style heat sink, side to side air flow PDF

    Documents mentioning HEAT FLOW SENSOR

    Document Partial File Text Tags Type PDF
    flow sensors
    & flow sensors Air & Gas Flow Flow measurement principle Inside each D6F there is a highly sensitive MEMS flow chip that is only 1.5mm2 x 0.4mm thick. The MEMS flow chip has two thermopiles on either side of a tiny heater element used to measure the deviations in heat
    Original PDF
    awm40000
    ISSUE 4 Installation Instructions for the AWM40000 Series Mass Gas-Flow Sensors PK 80005 GENERAL INFORMATION AWM40000 Series microbridge mass gas-flow sensors operate on the theory of heat transfer due to mass gas-flow across the surface of the sensing element. The sensing element consists of a resistor
    Original PDF
    airflow sensors
    Airflow Sensors Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer — flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced chip design, manufacturing techniques and microstructure
    Original PDF
    27160
    Heat Flux Sensor Type 27160 Heat Flow sensors allow precision measurements of heat transfer through any surface material. They are cemented onto a surface like strain gauges, and will give an accurate measurement of heat transfer using a DVM as an indicator.
    Original PDF
    flow sensors
    TD3180/90 Series – Thermal Dispersion Flow Sensors Rev. 4.02 ■ Operational Description The solid state sensor detects the dispersion/removal of heat from an element in the sensor. This removal of heat occurs as the media flows across the sensor, away from the heater. The heat
    Original PDF
    heat flow sensor
    TECHNICAL DATASHEET TEMPERATURE SENSORS P R E C I S I O N I N E L E C T R O N I C S Heat flux sensor type 20456-3 A quality high output heat flow sensor for precise measurement of heat transfer (loss or gain) through any surface material. Applications include:
    Original PDF
    TECHNICAL DATASHEET TEMPERATURE SENSORS P R E C I
    TECHNICAL DATASHEET TEMPERATURE SENSORS P R E C I S I O N I N E L E C T R O N I C S Heat flux sensor type 27160 Heat flow sensors allow precision measurements of heat transfer through any surface material. They are cemented onto a surface like strain gauges, and will give an accurate
    Original PDF
    RESISTOR PRODUCTS TRIMMER POTENTIOMETERS
    RESISTOR PRODUCTS TRIMMER POTENTIOMETERS SINGLE-TURN CERMET CHIP PVG3 Series FEATURES ■ Stable performance with unique sealed construction ■ Heat resistance performance enables high temperature peak re-flow soldering ■ Large and deep rotor groove provides easy adjustment
    Original PDF
    thermistor
    CHIP NTC THERMISTOR ■ FEATURES ·Miniature size ,No lead ,ideal for high density SMT installation ·Low resistance and high B-value series ·Superior solderability and resistance to soldering heat ·Ideal for wave or re-flow soldering ·Glass coating , high precision , small resistance drift
    Original PDF
    ■INSTALLATION 1.0 1. When installing the sensor,
    ■INSTALLATION 1.0 1. When installing the sensor, solder four tabs and terminals on PCB (t=1.6mm). Tabs can be bent only once. 2.5 Soldering iron Flow soldering Terminal : 350±5°C, 5s or less. Tab : 350±5°C, 10s or less. 2.5 3−φ1.0 12.5 Observe the following rules. If not, characteristics might vary due to soldering heat.
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors insertion style sensor with integrated processor
    Original PDF
    airflow sensors
    REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The
    Original PDF
    Subject to change without notice • © Hans Turck
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors in-line sensor with integrated processor
    Original PDF
    flow sensor
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 flow sensors in-line sensor with integrated processor
    Original PDF