HALL CURRENT TRANSDUCER 10A Search Results
HALL CURRENT TRANSDUCER 10A Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
MGN1D120603MC-R7 | Murata Manufacturing Co Ltd | DC-DC 1W SM 12-6/-3V GAN | |||
MGN1D050603MC-R7 | Murata Manufacturing Co Ltd | DC-DC 1W SM 5-6/-3V GAN | |||
MGN1S0512MC-R7 | Murata Manufacturing Co Ltd | DC-DC 1W SM 5-12V GAN | |||
MGN1S1212MC-R7 | Murata Manufacturing Co Ltd | DC-DC 1W SM 12-12V GAN | |||
MGN1S1208MC-R7 | Murata Manufacturing Co Ltd | DC-DC 1W SM 12-8V GAN |
HALL CURRENT TRANSDUCER 10A Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: CUSTOMER CUSTOMER CODE PART DESCRIPTION HALL EFFECT CURRENT TRANSDUCER CLOSED LOOP HCT 30A 1:1500 V. Output INTERNAL CODE HCT-PX5 DATE 05/11/10 EDITION 2 DOCUMENT NAME HCT-PX5_2.doc PAGE 1/6 HALL EFFECT CURRENT TRANSDUCER CLOSED LOOP 30A 1:1500 (V. Output) |
Original |
HCT-30PX5 | |
hall current transducer 10A
Abstract: hall ac current transducer 10A HCT-100 transducer diagram
|
Original |
||
hall current transducer 10A
Abstract: HCT-300LTP hall ac current transducer 10A AWG14 burden resistor
|
Original |
HCT-300LTP HCT-300LTP hall current transducer 10A hall ac current transducer 10A AWG14 burden resistor | |
Contextual Info: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-K7 This Hall Effect current sensor is based on open loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor. |
Original |
D-85464 CYHCS-K7-05A CYHCS-K7-10A CYHCS-K7-15A CYHCS-K7-20A CYHCS-K7-25A CYHCS-K7-30A CYHCS-K7-40A CYHCS-K7-50A | |
Contextual Info: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-K200 This Hall Effect current sensor is based on open loop principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the |
Original |
CYHCS-K200 CYHCS-K200 D-85464 | |
Contextual Info: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-B200 This Hall Effect current sensor is based on closed loop principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave |
Original |
CYHCS-B200 CYHCS-B200 D-85464 | |
Contextual Info: Technologies GmbH & Co KG Closed Loop Hall Current Sensor CYHCS-SYA This Hall Effect current sensor is based on the closed loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the |
Original |
D-85464 | |
Contextual Info: Technologies GmbH & Co KG Closed Loop Hall Current Sensor CYHCS-B8 This Hall Effect current sensor is based on the closed loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the |
Original |
D-85464 | |
Open Loop Current Transducer
Abstract: ta18.5a4v TA25A4V hall current transducer 5A hall current transducer 10A TA15A TA50A4V TA10A4V hall ac current transducer 10A Open Loop Current Transducer 20A
|
Original |
TA50A4V TA50A V080201 TA50A-P TA50A-P Open Loop Current Transducer ta18.5a4v TA25A4V hall current transducer 5A hall current transducer 10A TA15A TA50A4V TA10A4V hall ac current transducer 10A Open Loop Current Transducer 20A | |
hall current transducer 3A
Abstract: hall current transducer 5A
|
Original |
THDD50A V080201 hall current transducer 3A hall current transducer 5A | |
Contextual Info: SIOPSV1 Current Sensors Features Open loop transducer using the Hall effect Low voltage application Unipolar +5VDC power supply Primary current measuring range up to ±10. ±30A Operating temperature range:-40℃< TA<+85℃ Output voltage: fully ratio-metric gain and |
Original |
SIOPS10V1 SIOPS15V1 SIOPS20V1 SIOPS25V1 SIOPS30V1 | |
hall ac current transducer 10A
Abstract: welding inverter dc to ac
|
Original |
TGD40A V080708 0A-14A 5A-24A 5A-40A V0800708 hall ac current transducer 10A welding inverter dc to ac | |
tc25a4v
Abstract: hall current transducer 5A hall ac current transducer 10A tc50a4v
|
Original |
TC50A TC50A V080201 TC50A-P TC50A-P tc25a4v hall current transducer 5A hall ac current transducer 10A tc50a4v | |
hall current transducer 5A
Abstract: THP 100 16X2
|
Original |
THP50A V080201 THP25A hall current transducer 5A THP 100 16X2 | |
|
|||
hall current transducer 5A
Abstract: HY-10 transistor marking hy hy power HY-5 M 9639 20-P 25-P hall ac current transducer 10A ho 10-p
|
Original |
/-15V /-40mV hall current transducer 5A HY-10 transistor marking hy hy power HY-5 M 9639 20-P 25-P hall ac current transducer 10A ho 10-p | |
28644
Abstract: HA200-SB 500-SBD 25-NP 400-SID 200-SU PRIM configuration hall current transducer 10A hall current transducer LA 100P construction hall effect transducers
|
Original |
50/100A 28644 HA200-SB 500-SBD 25-NP 400-SID 200-SU PRIM configuration hall current transducer 10A hall current transducer LA 100P construction hall effect transducers | |
LV 25-P
Abstract: LV 25-NP HA200-SB hall current transducer LA 100P 286377 50psp1 200-SRI 500-SBD HT 200-srud PCB Mounting Hall Effect Current Transformer
|
Original |
50/100A LV 25-P LV 25-NP HA200-SB hall current transducer LA 100P 286377 50psp1 200-SRI 500-SBD HT 200-srud PCB Mounting Hall Effect Current Transformer | |
HT 200-srud
Abstract: 100ARMS HA200-SB schematic diagram induction heating hall current transducer 10A hall current transducer LA 100P voltage measurement LV 25-P PCB Mounting Hall Effect Current Transformer 200-SU 400-SID
|
Original |
50/100A HT 200-srud 100ARMS HA200-SB schematic diagram induction heating hall current transducer 10A hall current transducer LA 100P voltage measurement LV 25-P PCB Mounting Hall Effect Current Transformer 200-SU 400-SID | |
HA200-SB
Abstract: construction hall effect transducers 200-SI 500w power amplifier pcb diagram 100ARMS PCB Mounting Hall Effect Current Transformer HT 200-srud 25-NP HT 500 srud transducers
|
Original |
E17755 50/100A HA200-SB construction hall effect transducers 200-SI 500w power amplifier pcb diagram 100ARMS PCB Mounting Hall Effect Current Transformer HT 200-srud 25-NP HT 500 srud transducers | |
hall current sensor 10A
Abstract: HCT-1000LF ISO2768c hall effect current sensor 10A current loop sensor HCT-2000LF ISO2768-C curent sensor EN60947-1 IEC60950-1
|
Original |
HCT-2000LF mC60950-1 EN-50178 HCT-1000LF 200mA/1000A 2mA/10A 600mA/2000A hall current sensor 10A HCT-1000LF ISO2768c hall effect current sensor 10A current loop sensor ISO2768-C curent sensor EN60947-1 IEC60950-1 | |
Fluke 179 Multimeter circuit diagram
Abstract: flux multimeter
|
Original |
ACS704ELC-005 ACS704 ACS704ELC005-DS, Fluke 179 Multimeter circuit diagram flux multimeter | |
Fluke 179 Multimeter circuit diagram
Abstract: fluke 179 diagram
|
Original |
ACS704ELC-015 ACS704 ACS704ELC015-DS, Fluke 179 Multimeter circuit diagram fluke 179 diagram | |
Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER DHAB S/44 Introduction Principle of DHAB Family The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications. Its contains galvanic isolation between the primary |
Original |
30m/s2, | |
Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER DHAB S/06 Introduction Principle of DHAB Family The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications. Its contains galvanic isolation between the primary |
Original |
30m/s2, |