Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    H2S GA Search Results

    H2S GA Result Highlights (3)

    Part ECAD Model Manufacturer Description Download Buy
    LMP91002SDE/NOPB
    Texas Instruments Configurable AFE for Low Power H2S and CO Sensing Applications 14-WSON -40 to 85 Visit Texas Instruments Buy
    LMP91002SD/NOPB
    Texas Instruments Configurable AFE for Low Power H2S and CO Sensing Applications 14-WSON -40 to 85 Visit Texas Instruments Buy
    LMP91002SDX/NOPB
    Texas Instruments Configurable AFE for Low Power H2S and CO Sensing Applications 14-WSON -40 to 85 Visit Texas Instruments Buy

    Documents mentioning H2S GA

    Document Partial File Text Tags Type PDF
    α S H2S-B1 Hydrogen Sulfide Sensor PATENT PENDING
    α S H2S-B1 Hydrogen Sulfide Sensor PATENT PENDING Technical Specification Figure 1 H2S-B1 Schematic Diagram All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View Table 1 H2S-B1 Specification PERFORMANCE * Sensitivity LIFETIME * Response time
    Original PDF
    α S H2S-AH Hydrogen Sulfide Sensor PATENT PENDING
    α S H2S-AH Hydrogen Sulfide Sensor PATENT PENDING Technical Specification Figure 1 H2S-AH Schematic Diagram All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View Table 1 H2S-AH Specification PERFORMANCE * Sensitivity LIFETIME * Response time
    Original PDF
    α S H2S-BE Hydrogen Sulfide Sensor PATENT PENDING
    α S H2S-BE Hydrogen Sulfide Sensor PATENT PENDING Technical Specification Figure 1 H2S-BE Schematic Diagram All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View Table 1 H2S-BE Specification PERFORMANCE * Sensitivity LIFETIME * Response time
    Original PDF
    α S H2S-BH Hydrogen Sulfide Sensor PATENT PENDING
    α S H2S-BH Hydrogen Sulfide Sensor PATENT PENDING Technical Specification Figure 1 H2S-BH Schematic Diagram All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View Table 1 H2S-BH Specification PERFORMANCE Sensitivity Response time Zero current
    Original PDF
    h2s-a1
    α S H2S-A1 Hydrogen Sulfide Sensor PATENT PENDING Technical Specification Figure 1 H2S-A1 Schematic Diagram All dimensions in millimetres (± 0.1mm) Top View Bottom View Side View Table 1 H2S-A1 Specification PERFORMANCE * Sensitivity LIFETIME * Response time
    Original PDF
    h2s-d1
    Miniature Size PATENT PENDING Figure 1 H2S-D1 Schematic Diagram í é ê ì 3 Ø13 ç Counter è é ë è ê é 8.4 R1.8 ç è Ø14.5 ç 2.5 Technical Specification Sensing Area Do Not Cover 1 S ê Reference Working é ì 4 α H2S-D1 Hy dr og en Sulf
    Original PDF
    vq101ht
    VQ101HT Solid-State Gas Sensor Elements for Hydrogen Sulfide monitoring FEATURES • 0 - 50 ppm range H2S • 0.2 ppm resolution • High temperature +90 °C operation • Fast response time (t90) • Solid state technology • Designed for continuous operation
    Original PDF
    Lever Switches Application Notes 3. Mounting
    Lever Switches Application Notes 3. Mounting Conditions These lever switches are not suitable as sealed types, so the possibility of irreparable damage exists under the following conditions. (1) Corrosive gas atmosphere of Cl 2, H2S, NH 3, No x, SO2, etc.
    Original PDF
    dc24v
    GT Serial toxic gas transmitter ◆ Hanging or piping installation ◆ Used in metallurgy, pharmacy, petrochemical industries ◆ O2, C0, H2S, H2, CL2, SO2, NO2 etc. can be detected ◆ Power: DC24V ◆ Output: 4~20mA ◆ Signal transmit distance: ≤ 1000 M
    Original PDF
    gas chromatograph
    Data Sheet Process Gas Chromatograph PGC1000 Analyzer Products Field Mounted GC DESCRIPTION STANDARD FEATURES The PGC1000 is a field mounted GC using two analytical trains per analyzer that enable measurements of C1 thru C9+, inerts and H2S in various Hydrocarbon Processing Industry (HPI) streams.
    Original PDF
    dp83266
    NATL SEHICON]> (LINEAR) (□501124 QQÖ334S H2S bbE ]> PRELIMINARY DP83266 MACSI™ Device (FDDI Media Access Controller and System Interface) On-chip address bit swapping capability 32-bit wide Address/Data path with byte parity Programmable transfer burst sizes of 4 or 8
    OCR Scan PDF
    Resistors Operation notes !Cautions when handling
    Resistors Operation notes !Cautions when handling resistors. 1. Oxidation will form on electrodes very easily. Store in the proper atmosphere(Storage condition : 5∼40°C, 30∼80% RH). And avoid to store in the environments full of sea breeze, H2S, Cl2, NO2, SO2, and NH3,
    Original PDF
    . “ _ ' /… 07 4016775 GLOW-LITE CORP T'^h2S D E |
    . “ _ ' /… 07 4016775 GLOW-LITE CORP T'^h2S D E | M D l b 7 7 S ~ OQOOGSO S | ~ G L O lilt e □ MULTI-COLOR LED LAMPS Chip Lam p Size 1 T-1 3.0mm Round 1.0” Lead Length GaP Bright Retf GaP Green Ga AsP/GaP Orange Diffused PD (mW) Ip (m A) Peak If
    OCR Scan PDF