MSR12T
Abstract: MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am
Contextual Info: MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE b Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only
|
Original
|
msr12ts13-s14s23-s2498/37/ec+1173/23/eec89/336/eecmsr12guardmaster control unitguardmaster control unit en 60204-1guardmaster35mmen292en954-1guardmaster wn2 4hrfusible am
|
PDF
|
GuardMaster ferrogard 21DC
Abstract: BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster
Contextual Info: FERROGARD GD2 b Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch
|
Original
|
98/37/ec73/23/eecguardmaster ferrogard 21dcbs3146+8guardmaster control unit en 60204-1ferrogard 21dcguardmaster gd2ferrogard 2acguardmaster en1088reed magneteinterrupteur commutateurguardmaster
|
PDF
|
MSR11R
Abstract: GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020
Contextual Info: a MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously
|
Original
|
msr11r98/37/ec73/23/eec89/336/eec+9guardmaster control unit en 60204-1minotauralimentation pcguardmaster control unitdeutsch relay 4aguardmaster safety switchmsr11msr12ten6020
|
PDF
|
GuardMaster CONTROL UNIT EN 60204-1
Abstract: MSR16 GuardMaster safety switch GuardMaster safety switch msr16 EN1050 GuardMaster CONTROL UNIT diode led rouge 3 mm GuardMaster 1800W EN60204-1
Contextual Info: a MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after
|
Original
|
msr16r/ts13-s14s23-s24msr16+1198/37/ec73/23/eecguardmaster control unit en 60204-1guardmaster safety switchguardmaster safety switch msr16en1050guardmaster control unitdiode led rouge 3 mmguardmaster1800wen60204-1
|
PDF
|
guardmaster cu2
Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204
Contextual Info: a CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor
|
Original
|
98/37/ec73/23/eecguardmaster cu2guardmaster control unit en 60204-1+8guardmaster gd2guardmaster6 volt dc to 110v ac inverter circuit diagramguardmaster control unit cu2 stop motion detectionfuse 500maguardmaster wn2 4hrdiode led rouge 5mmguardmaster control unit cu2 en 60204
|
PDF
|
guardmaster atlas 4
Abstract: GuardMaster atlas 5 gd2 guardmaster atlas 3 safety switch guardmaster atlas safety switch cerberus cu2 ATLAS 5 gd2 guardmaster safety switch bouton poussoir ci guardmaster atlas 4 safety switch GuardMaster guardmaster cu2
Contextual Info: ATLAS 5-GD2 a HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the
|
Original
|
guardmaster atlas 4guardmaster atlas 5 gd2guardmaster atlas 3 safety switchguardmaster atlas safety switch+6cerberus cu2atlas 5 gd2 guardmaster safety switchbouton poussoir ciguardmaster atlas 4 safety switchguardmasterguardmaster cu2
|
PDF
|
GuardMaster trojan 5
Abstract: GuardMaster trojan 5 EX GuardMaster trojan 5 6 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH guardmaster trojan 5 AC15 trojan 5 bouton poussoir GuardMaster CONTROL UNIT EN 60204-1 GuardMaster wn2 4hr
Contextual Info: TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 a Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.
|
Original
|
guardmaster trojan 5guardmaster trojan 5 exguardmaster trojan 5 6guardmaster iec 60947-5-1+6guardmaster catalogue safety switchguardmaster trojan 5 ac15trojan 5bouton poussoirguardmaster control unit en 60204-1guardmaster wn2 4hr
|
PDF
|
GuardMaster
Abstract: MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique
Contextual Info: a Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite
|
Original
|
98/37/ec73/23/eec89/336/eecguardmaster+9msr6r/tminotaur msr6r/tmsr7r1000v contactorguardmaster control unitwn2 4hrminotaurguardmaster wn2 4hrcircuit logique
|
PDF
|
MSR15D
Abstract: bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA
Contextual Info: Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät
|
Original
|
msr15dd13/d14ortiebouton poussoir ciguardmaster+7guardmaster safety switchguardmaster control unit en 60204-1en1050anzeigeguardmaster control unittuv sp1000va
|
PDF
|
GuardMaster ferrogard 21DC
Abstract: Ferrogard 21DC FERROCODE EN60204 Ferrogard 21AC GuardMaster FRS 6 frs3 relay ferrogard Guardmaster EN1088 frs 21 dc guardmaster
Contextual Info: a Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details.
|
Original
|
guardmaster ferrogard 21dcferrogard 21dcferrocode en60204ferrogard 21ac+6guardmaster frs 6frs3 relayferrogardguardmaster en1088frs 21 dcguardmaster
|
PDF
|
GuardMaster gd2
Abstract: guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600
Contextual Info: a CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions
|
Original
|
98/37/ec73/23/eecguardmaster gd2guardmaster iec 60947-5-1+8guardmaster catalogue safety switchguardmaster cadet 3gd2 guardmasterguardmaster control unit en 60204-1guardmaster control unitguardmaster safety switch9053ba600
|
PDF
|
MSR9T
Abstract: A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T
Contextual Info: ACCESSOIRES ZUBEHÖR e ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function
|
Original
|
ul508msr9ta600gs-et-15+5iec68guardmaster iec 60947-5-1guardmaster gd2guardmaster control unit en 60204-1minotaur msr9t
|
PDF
|
minotaur MSR6R/T Universal Safety Relay
Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique
Contextual Info: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.
|
Original
|
s13-s14s23-s24minotaur msr6r/t universal safety relayguardmaster control unit en 60204-1+8guardmasterguardmaster control unitminotaur msr6r/tguardmaster wn2 4hrmsr6r/twn2 4hrguardmaster safety switchlogique
|
PDF
|
GuardMaster
Abstract: C3003 GuardMaster safety switch GuardMaster wn2 4hr guardmaster IEC 60947-5-1 MT-GD2 wn2 4HR GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur
Contextual Info: HEAVY DUTY, TONGUE OPERATED GUARD INTERLOCK SWITCH MT-GD2 a The MT-GD2 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.
|
Original
|
98/37/ec73/23/eecguardmasterc3003+8guardmaster safety switchguardmaster wn2 4hrguardmaster iec 60947-5-1mt-gd2wn2 4hrguardmaster gd2guardmaster control unit en 60204-1minotaur
|
PDF
|
|
|
GuardMaster CONTROL UNIT EN 60204-1
Abstract: minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT
Contextual Info: MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633
|
Original
|
120mmguardmaster control unit en 60204-1minotaur msr9tguardmaster safety switch+7guardmaster wn2 4hrmsr9ts2213wn2 4hren 60204-1fuse 500maguardmaster control unit
|
PDF
|
Guardmaster EN1088
Abstract: BS5304 EN1088 GS-ET-15 GuardMaster wn2 4hr GuardMaster safety switch GS-ET15 BS53 wn2 4HR JET 2A 250V
Contextual Info: INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG / NOTICE D'INSTALLATION 4 1mm min 2.5mm max 2 x M4 2 6 2 x M4 5 1 3 2.5mm y Entr End mm & nt Fro in. 150 m B1 B2 0mm . 20 mm n i try m 150 t En min. Fron Entry End 2 x M4 2 ELF 1 Conduit M16 PG9 entry Part 33001 33002
|
Original
|
guardmaster en1088bs5304en1088gs-et-15+6guardmaster wn2 4hrguardmaster safety switchgs-et15bs53wn2 4hrjet 2a 250v
|
PDF
|
l455
Abstract: minotaur msr8t GuardMaster wn2 4hr S14 contactor DC-13 wn2 4HR DIN VDE 0113 switch GuardMaster safety switch msr8t GuardMaster minotaur msr6r/t
Contextual Info: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformiätserklärung. Voir la declaration de conformite ä-jointe pour details MINOTAUR MSR8T SINGLE CHANNEL INPUT MONITORING SAFETY RELAY & EXTENSION UNIT. RELAIS-SICHERHEITSBAUSTEIN FÜR SICHERHEITSSCHALTER UND NOT-AUS-BEFEHLSGERÄTE 1-KANALIGER EINGANG UND ERWEITERUNGSEINHEIT.
|
Original
|
110vacfroms13230vacl455+9minotaur msr8tguardmaster wn2 4hrs14 contactordc-13wn2 4hrdin vde 0113 switchguardmaster safety switch msr8tguardmasterminotaur msr6r/t
|
PDF
|
GuardMaster wn2 4hr
Abstract: 02ATEX0183X EN50018 BS6007 guardmaster GuardMaster wn2 BS60079-14 EExdIIct6 GS213 500VA
Contextual Info: FERROGARD MAGLOCK GS2, GS2H & GS2-1 GUARD SWITCHES Certification for GS2 & GS2-1. EExdIICT6 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000. Certification for GS2H. EExdIICT3 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000
|
Original
|
02atex0183xen50014en50018bs60079-14+9110va220va500vaguardmaster wn2 4hrbs6007guardmasterguardmaster wn2eexdiict6gs213
|
PDF
|
guardmaster cu2
Abstract: CU2 STOP MOTION DETECTION stop motion detector with pnp and npn sensor 6 way rotary selector switch dc sensor movimento 500mAT motion detector WITH RELAY switch wn2 4HR inductive sensor
Contextual Info: ENGLISH The CU2 provides a stopped motion detection system and is used together with CU2 sensors supplied separately to detect movement of a machine via the flywheel, gear or shaft etc. Upon energisation the unit powers up (Red LED). When the sensor detects that the
|
Original
|
guardmaster cu2cu2 stop motion detectionstop motion detector with pnp and npn sensor6 way rotary selector switch dc+5sensor movimento500matmotion detector with relay switchwn2 4hrinductive sensor
|
PDF
|
GuardMaster safety switch
Abstract: wn2 4HR guardmaster 24VAC GuardMaster wn2 4hr minotaur msr7c EN60204-1 relay in ac application GuardMaster CONTROL UNIT
Contextual Info: R MINOTAUR MSR7C 2 HAND CONTROL LOGIC UNIT For Capacitive Palm Button 2 hand control switch units with 2 x 1 N/O & 1N/C buttons. Power drain: Internal fuse: Safety Inputs: Indication: Relay outputs: Maximum switched current: Drop out time: Standards conformity:
|
Original
|
500matguardmaster safety switchwn2 4hrguardmaster+724vacguardmaster wn2 4hrminotaurmsr7cen60204-1relay in ac applicationguardmaster control unit
|
PDF
|