Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    GUARDMASTER WN Search Results

    Documents mentioning GUARDMASTER WN

    Document Partial File Text Tags Type PDF
    msr12t
    MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE (b) Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only
    Original PDF
    ferro
    FERROGARD GD2 (b) Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch
    Original PDF
    minotaur
    (a) MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously
    Original PDF
    msr16
    (a) MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after
    Original PDF
    (a) CU3 Description The CU3 has been designed to
    (a) CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor
    Original PDF
    solenoid lock
    ATLAS 5-GD2 (a) HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the
    Original PDF
    trojan 5
    TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 (a) Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.
    Original PDF
    minotaur
    (a) Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite
    Original PDF
    msr15d
    Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät
    Original PDF
    ferrogard
    (a) Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details.
    Original PDF
    (a) CADET 3 Description The Cadet 3 is a positive
    (a) CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions
    Original PDF
    ACCESSOIRES ZUBEHÖR (e) ACCESSORIES Security
    ACCESSOIRES ZUBEHÖR (e) ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function
    Original PDF
    minotaur msr6r/t
    See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.
    Original PDF
    mt-gd2
    HEAVY DUTY, TONGUE OPERATED GUARD INTERLOCK SWITCH MT-GD2 (a) The MT-GD2 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.
    Original PDF
    See enclosed Declaration of Conformity for
    See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. SPECIALISTS IN MACHINERY SAFETY UL C UL R 940060 R Listed UNIVERSAL TONGUE OPERATED SAFETY INTERLOCK SWITCH.
    Original PDF
    minotaur msr9t
    MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633
    Original PDF
    INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG /
    INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG / NOTICE D'INSTALLATION 4 1mm min 2.5mm max 2 x M4 2 6 2 x M4 5 1 3 2.5mm y Entr End mm & nt Fro in. 150 m B1 B2 0mm . 20 mm n i try m 150 t En min. Fron Entry End 2 x M4 2 ELF 1 Conduit M16 PG9 entry Part 33001 33002
    Original PDF
    minotaur msr8t
    See enclosed Declaration of Conformity for details. Siehe Anlage: Konformiätserklärung. Voir la declaration de conformite ä-jointe pour details MINOTAUR MSR8T SINGLE CHANNEL INPUT MONITORING SAFETY RELAY & EXTENSION UNIT. RELAIS-SICHERHEITSBAUSTEIN FÜR SICHERHEITSSCHALTER UND NOT-AUS-BEFEHLSGERÄTE (1-KANALIGER EINGANG) UND ERWEITERUNGSEINHEIT.
    Original PDF
    ferrogard
    FERROGARD MAGLOCK GS2, GS2H & GS2-1 GUARD SWITCHES Certification for GS2 & GS2-1. EExdIICT6 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000. Certification for GS2H. EExdIICT3 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000
    Original PDF
    ENGLISH The CU2 provides a stopped motion
    ENGLISH The CU2 provides a stopped motion detection system and is used together with CU2 sensors (supplied separately) to detect movement of a machine via the flywheel, gear or shaft etc. Upon energisation the unit powers up (Red LED). When the sensor detects that the
    Original PDF
    minotaur
    R MINOTAUR MSR7C 2 HAND CONTROL LOGIC UNIT For Capacitive Palm Button 2 hand control switch units with 2 x 1 N/O & 1N/C buttons. Power drain: Internal fuse: Safety Inputs: Indication: Relay outputs: Maximum switched current: Drop out time: Standards conformity:
    Original PDF