GuardMaster Catalogue SAFETY SWITCH
Abstract: GuardMaster trojan 5 6 GuardMaster lifeline 4 440EH13046 GuardMaster trojan 5 GuardMaster TIME DELAY BOLT GuardMaster trojan 5 EX GuardMaster CENTURION CP15-EX 440K-H11161
Contextual Info: Hazardous Location & Pneumatic Switches Explosion Proof Ex Range Specifications NRTL/C Description Guardmaster Ex Range The Guardmaster Ex range of safety switches are specifically designed for potentially explosive atmospheres. They retain the safety features and operating principles of the conventional Guardmaster
|
Original
|
440e-h13046440e-h13069440h-h03077440h-h03100+16440k-h04035440k-h04037440k-h04036440k-h04038440e-h05004440e-h05019guardmaster catalogue safety switchguardmaster trojan 5 6guardmaster lifeline 4440eh13046guardmaster trojan 5guardmaster time delay boltguardmaster trojan 5 exguardmaster centurioncp15-ex440k-h11161
|
PDF
|
GuardMaster
Abstract: EN60204-1 EN60204 plc projects EN954-1
Contextual Info: Guardmaster - Minotaur Page 1 of 3 0000 Contacts 2 Safety, 1 off Delay Safety + 1 Aux outputs Protection IP20 Conduit Entries 10/01/2003 Guardmaster - Minotaur Page 2 of 3 N/A Fixing 35mm DIN Rail
|
Original
|
20sales\paramet\3055413en60204-1en954-1120mm+3guardmasteren60204plc projects
|
PDF
|
IEC60068-2-29
Abstract: MSR126.1T msr127 1606-XLP72E Allen-Bradley MSR127 440L-P4K1120YD 440R-P23071 MSR126T 440R-N23135 GuardMaster light curtains
Contextual Info: Presence Sensing Safety Devices Safety Light Curtains GuardShield Type 4 Specifications Description The Allen-Bradley Guardmaster GuardShield safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. GuardShield safety light curtains are general
|
Original
|
160mm1760mm3-7m/14mm3m-18m/30mm+1398-59ft/114mm/30mm55in/1msr127iec60068-2-29msr126.1t1606-xlp72eallen-bradley msr127440l-p4k1120yd440r-p23071msr126t440r-n23135guardmaster light curtains
|
PDF
|
MSR126.1T
Abstract: MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114
Contextual Info: Safety Relays Monitoring Safety Relays Minotaur MSR126R/T Specifications Description The Allen-Bradley Guardmaster Minotaur MSR126R/T is a safety monitoring relay that provides the very basics for safety control systems in a 22.5mm package. The MSR126R/T is designed for connection to a single channel
|
Original
|
msr126r/ten954-1iso13849-1en60204-1+15iec60947-4-1iec60947-5-1as402442/115/230v50/60hzmsr126.1tmsr126tmsr126440rn23114440r-n23117440r-n23120guardmaster msr126rmsr126rmsr126.1r440r-n23114
|
PDF
|
440EL13193
Abstract: 440EL13137 440EL22BNST 440EL22BNSM GuardMaster lifeline 4 440EL13166 440EL13153 440EL13131 guardmaster 440 440EL22BNSL
Contextual Info: Product Safety Group 1201 South Second Street Milwaukee, WI USA 53204 productsafety@ra.rockwell.com PRODUCT SAFETY ADVISORY Notice of Potential Unsafe Condition GuardMaster Lifeline 4 Cable Pull Switches Reference: 2010-05-001 Revision: A Date: May 2010 June 2010
|
Original
|
440el13193440el13137440el22bnst440el22bnsm+6guardmaster lifeline 4440el13166440el13153440el13131guardmaster 440440el22bnsl
|
PDF
|
Allen-Bradley en60204-1
Abstract: allen bradley contactor B300 440R-D23021 MSR7R EN574 FUSE 451 440R D23021 440r-d23025 440R-D23022 IEC60947-5-1
Contextual Info: Safety Relays Two Hand Relays Minotaur MSR7R & MSR7C Specifications Description The Allen-Bradley Guardmaster Minotaur MSR7R & MSR7C are logic units for monitoring and interfacing two hand control devices with a safety related circuit. The MSR7R is for use with mechanical
|
Original
|
en574en954-1iso13849-1iec/en60204-1+10iec60947-5-1as4024allen-bradley en60204-1allen bradley contactor b300440r-d23021msr7rfuse 451440r d23021440r-d23025440r-d23022
|
PDF
|
XLP-3
Abstract: 440C-ENET 440C-CR30-22BBB
Contextual Info: User Manual — Original Language Guardmaster 440C-CR30 Configurable Safety Relay Catalog Number 440C-CR30-22BBB Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and
|
Original
|
440c-cr30440c-cr30-22bbbra-du002440c-um001d-en-p+3440c-um001c-en-pxlp-3440c-enet
|
PDF
|
GuardMaster ferrogard 21DC
Abstract: BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster
Contextual Info: FERROGARD GD2 b Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch
|
Original
|
98/37/ec73/23/eecguardmaster ferrogard 21dcbs3146+8guardmaster control unit en 60204-1ferrogard 21dcguardmaster gd2ferrogard 2acguardmaster en1088reed magneteinterrupteur commutateurguardmaster
|
PDF
|
MSR12T
Abstract: MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am
Contextual Info: MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE b Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only
|
Original
|
msr12ts13-s14s23-s2498/37/ec+1173/23/eec89/336/eecmsr12guardmaster control unitguardmaster control unit en 60204-1guardmaster35mmen292en954-1guardmaster wn2 4hrfusible am
|
PDF
|
MSR11R
Abstract: GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020
Contextual Info: a MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously
|
Original
|
msr11r98/37/ec73/23/eec89/336/eec+9guardmaster control unit en 60204-1minotauralimentation pcguardmaster control unitdeutsch relay 4aguardmaster safety switchmsr11msr12ten6020
|
PDF
|
guardmaster atlas 4
Abstract: GuardMaster atlas 5 gd2 guardmaster atlas 3 safety switch guardmaster atlas safety switch cerberus cu2 ATLAS 5 gd2 guardmaster safety switch bouton poussoir ci guardmaster atlas 4 safety switch GuardMaster guardmaster cu2
Contextual Info: ATLAS 5-GD2 a HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the
|
Original
|
guardmaster atlas 4guardmaster atlas 5 gd2guardmaster atlas 3 safety switchguardmaster atlas safety switch+6cerberus cu2atlas 5 gd2 guardmaster safety switchbouton poussoir ciguardmaster atlas 4 safety switchguardmasterguardmaster cu2
|
PDF
|
GuardMaster CONTROL UNIT EN 60204-1
Abstract: MSR16 GuardMaster safety switch GuardMaster safety switch msr16 EN1050 GuardMaster CONTROL UNIT diode led rouge 3 mm GuardMaster 1800W EN60204-1
Contextual Info: a MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after
|
Original
|
msr16r/ts13-s14s23-s24msr16+1198/37/ec73/23/eecguardmaster control unit en 60204-1guardmaster safety switchguardmaster safety switch msr16en1050guardmaster control unitdiode led rouge 3 mmguardmaster1800wen60204-1
|
PDF
|
GuardMaster trojan 5
Abstract: GuardMaster trojan 5 EX GuardMaster trojan 5 6 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH guardmaster trojan 5 AC15 trojan 5 bouton poussoir GuardMaster CONTROL UNIT EN 60204-1 GuardMaster wn2 4hr
Contextual Info: TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 a Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.
|
Original
|
guardmaster trojan 5guardmaster trojan 5 exguardmaster trojan 5 6guardmaster iec 60947-5-1+6guardmaster catalogue safety switchguardmaster trojan 5 ac15trojan 5bouton poussoirguardmaster control unit en 60204-1guardmaster wn2 4hr
|
PDF
|
GuardMaster
Abstract: MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique
Contextual Info: a Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite
|
Original
|
98/37/ec73/23/eec89/336/eecguardmaster+9msr6r/tminotaur msr6r/tmsr7r1000v contactorguardmaster control unitwn2 4hrminotaurguardmaster wn2 4hrcircuit logique
|
PDF
|
|
|
GuardMaster gd2
Abstract: guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600
Contextual Info: a CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions
|
Original
|
98/37/ec73/23/eecguardmaster gd2guardmaster iec 60947-5-1+8guardmaster catalogue safety switchguardmaster cadet 3gd2 guardmasterguardmaster control unit en 60204-1guardmaster control unitguardmaster safety switch9053ba600
|
PDF
|
GuardMaster
Abstract: C3003 GuardMaster safety switch GuardMaster wn2 4hr guardmaster IEC 60947-5-1 MT-GD2 wn2 4HR GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur
Contextual Info: HEAVY DUTY, TONGUE OPERATED GUARD INTERLOCK SWITCH MT-GD2 a The MT-GD2 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.
|
Original
|
98/37/ec73/23/eecguardmasterc3003+8guardmaster safety switchguardmaster wn2 4hrguardmaster iec 60947-5-1mt-gd2wn2 4hrguardmaster gd2guardmaster control unit en 60204-1minotaur
|
PDF
|
GuardMaster trojan 5
Abstract: GuardMaster trojan 5 6 guardmaster 947-5-1 GuardMaster guardmaster IEC 947-5-1 GuardMaster wn2 4hr IEC 60947-5-1 ip 67 Guardmaster EN1088 guardmaster IEC 60947-5-1 trojan 5
Contextual Info: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. SPECIALISTS IN MACHINERY SAFETY UL C UL R 940060 R Listed UNIVERSAL TONGUE OPERATED SAFETY INTERLOCK SWITCH.
|
Original
|
175mm75mm2ul508guardmaster trojan 5+9guardmaster trojan 5 6guardmaster 947-5-1guardmasterguardmaster iec 947-5-1guardmaster wn2 4hriec 60947-5-1 ip 67guardmaster en1088guardmaster iec 60947-5-1trojan 5
|
PDF
|
GuardMaster CONTROL UNIT EN 60204-1
Abstract: minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT
Contextual Info: MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633
|
Original
|
120mmguardmaster control unit en 60204-1minotaur msr9tguardmaster safety switch+7guardmaster wn2 4hrmsr9ts2213wn2 4hren 60204-1fuse 500maguardmaster control unit
|
PDF
|
minotaur MSR6R/T Universal Safety Relay
Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique
Contextual Info: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.
|
Original
|
s13-s14s23-s24minotaur msr6r/t universal safety relayguardmaster control unit en 60204-1+8guardmasterguardmaster control unitminotaur msr6r/tguardmaster wn2 4hrmsr6r/twn2 4hrguardmaster safety switchlogique
|
PDF
|
guardmaster cu2
Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204
Contextual Info: a CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor
|
Original
|
98/37/ec73/23/eecguardmaster cu2guardmaster control unit en 60204-1+8guardmaster gd2guardmaster6 volt dc to 110v ac inverter circuit diagramguardmaster control unit cu2 stop motion detectionfuse 500maguardmaster wn2 4hrdiode led rouge 5mmguardmaster control unit cu2 en 60204
|
PDF
|
GuardMaster TLS2 gd2
Abstract: GuardMaster gd2 TLS1 GD2 GuardMaster tls-1 TLS-1 GD2 27122 GuardMaster safety switch gd2 manual GuardMaster TLS3-GD2 gd2 guardmaster TLS-GD2 TLS1-GD2
Contextual Info: Robust, A tongue operated interlocking with guard locking Guardmaster's newTLS-G D2 is a robust interlocking safety switch fo r Holds guard shut until machine is signalled safe guard locking. It is designed w ith a stainless steel actuator entry guide Holding force up to of 2000N
|
OCR Scan
|
2000nguardmaster tls2 gd2guardmaster gd2tls1 gd2+7guardmaster tls-1tls-1 gd2 27122guardmaster safety switch gd2 manualguardmaster tls3-gd2gd2 guardmastertls-gd2tls1-gd2
|
PDF
|
MSR15D
Abstract: bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA
Contextual Info: Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät
|
Original
|
msr15dd13/d14ortiebouton poussoir ciguardmaster+7guardmaster safety switchguardmaster control unit en 60204-1en1050anzeigeguardmaster control unittuv sp1000va
|
PDF
|
MSR9T
Abstract: A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T
Contextual Info: ACCESSOIRES ZUBEHÖR e ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function
|
Original
|
ul508msr9ta600gs-et-15+5iec68guardmaster iec 60947-5-1guardmaster gd2guardmaster control unit en 60204-1minotaur msr9t
|
PDF
|
PILZ pnoz
Abstract: guardmaster atlas 3 safety switch Pilz safety relay Electronic security code lock system - Door Lock - Safe Lock circuit diagram guardmaster atlas 4 GuardMaster CENTURION circuit diagram of door interlock system guardmaster atlas safety switch 343-981 323-987
Contextual Info: Issued November 1993 B16718 Machineguardinterlocking RS stock no. 325-703 323-993 351-241 351-257 323-971 323-987 325-141 325-157 325-129 325-135 324-772 333-574 759-213 343-981 350-074 319-663 319-269 319-275 319-281 Description Rotacam 2N/C contact block
|
Original
|
b16718pilz pnozguardmaster atlas 3 safety switchpilz safety relay+7electronic security code lock system - door lock - safe lock circuit diagramguardmaster atlas 4guardmaster centurioncircuit diagram of door interlock systemguardmaster atlas safety switch343-981323-987
|
PDF
|