GUARDMASTER CONTROL UN Search Results
GUARDMASTER CONTROL UN Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TB6551FAG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=12/Sine Wave | Datasheet | ||
| TB6586FG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave | Datasheet | ||
| TB6586BFG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave | Datasheet | ||
| TB6586AFG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave | Datasheet | ||
| TB6556FG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=12/Square, Sine Wave | Datasheet |
Documents mentioning GUARDMASTER CONTROL UN
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| minotaur | Safety Relays Two Hand Relays Minotaur MSR7R & MSR7C Specifications Description The Allen-Bradley Guardmaster Minotaur MSR7R & MSR7C are logic units for monitoring and interfacing two hand control devices with a safety related circuit. The MSR7R is for use with mechanical |
Original | ||||
| msr126 | Safety Relays Monitoring Safety Relays Minotaur MSR126R/T Specifications Description The Allen-Bradley Guardmaster Minotaur MSR126R/T is a safety monitoring relay that provides the very basics for safety control systems in a 22.5mm package. The MSR126R/T is designed for connection to a single channel |
Original | ||||
| msr12t | MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE (b) Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only |
Original | ||||
| minotaur | (a) Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite |
Original | ||||
| minotaur | (a) MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously |
Original | ||||
| solenoid lock | ATLAS 5-GD2 (a) HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the |
Original | ||||
| msr16 | (a) MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after |
Original | ||||
| msr15d | Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät |
Original | ||||
| minotaur msr6r/t | See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte. |
Original | ||||
| (a) CU3 Description The CU3 has been designed to | (a) CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor |
Original | ||||
| ferro | FERROGARD GD2 (b) Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch |
Original | ||||
| trojan 5 | TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 (a) Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. |
Original | ||||
| 323-987 | Issued November 1993 B16718 Machineguardinterlocking RS stock no. 325-703 323-993 351-241 351-257 323-971 323-987 325-141 325-157 325-129 325-135 324-772 333-574 759-213 343-981 350-074 319-663 319-269 319-275 319-281 Description Rotacam 2N/C contact block |
Original | ||||
| (a) CADET 3 Description The Cadet 3 is a positive | (a) CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions |
Original | ||||
|
|
||||||
| ACCESSOIRES ZUBEHÖR (e) ACCESSORIES Security | ACCESSOIRES ZUBEHÖR (e) ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function |
Original | ||||
| mt-gd2 | HEAVY DUTY, TONGUE OPERATED GUARD INTERLOCK SWITCH MT-GD2 (a) The MT-GD2 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. |
Original | ||||
| ferrogard | (a) Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details. |
Original | ||||
| 440c-cr30-22bbb | User Manual — Original Language Guardmaster 440C-CR30 Configurable Safety Relay Catalog Number 440C-CR30-22BBB Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and |
Original | ||||
| minotaur msr9t | MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633 |
Original | ||||
| Presence Sensing Safety Devices Safety Light | Presence Sensing Safety Devices Safety Light Curtains Point of Operation Control Maximum scanning range 6m/18m (19.69ft/59.06ft) Resolution (object sensitivity) 14mm/30mm (0.55in/1.18in) Maximum height of protective field 1814mm/1832mm (71.4in/72.1in) Minimum height of protective field |
Original | ||||
| minotaur | R MINOTAUR MSR7C 2 HAND CONTROL LOGIC UNIT For Capacitive Palm Button 2 hand control switch units with 2 x 1 N/O & 1N/C buttons. Power drain: Internal fuse: Safety Inputs: Indication: Relay outputs: Maximum switched current: Drop out time: Standards conformity: |
Original | ||||
| iec 60947-5-1 | Safety Relays Timing Control Units CU1 Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 per EN 954-1 (ISO13849-1) Approvals C-Tick, CE marked for all applicable directives, cULus & TÜV Power Supply |
Original | ||||
| msr125h | Safety Relays Two Hand Relays Minotaur MSR125H/HP Specifications Standards EN 574, EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 (ISO 13849-1) Cat. IIIC per EN 574 Approvals C-Tick, CE marked for all |
Original | ||||
| Safe-Off Option for PowerFlex® 700S Phase II AC | Safe-Off Option for PowerFlex® 700S Phase II AC Drives and PowerFlex 700L Liquid-Cooled AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and |
Original | ||||
| ferrogard | Interlock Switches Non contact Switches Ferrogard GS1 & GS2 Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems |
Original | ||||