GROUND FAULT INTERRUPTE Search Results
GROUND FAULT INTERRUPTE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| AFE3010EVM | Texas Instruments | AFE3010 ground fault circuit interrupter (GFCI) evaluation module |
|
|
|
| AFE3010AIRGTR | Texas Instruments | Ground fault circuit interrupter (GFCI) with self-test and neutral-ground fault detection 16-VQFN -40 to 105 |
|
||
| 5640383553 | Amphenol Communications Solutions | VHDM®, Backplane connectors, Grounding Guide Pin | |||
| 10053870-0150LF | Amphenol Communications Solutions | CF CARD EJECTOR-LEFT PUSH ROD, WITH GROUND | |||
| 10053870-0050LF | Amphenol Communications Solutions | CF CARD EJECTOR-LEFT PUSH ROD, WITH GROUND |
Documents mentioning GROUND FAULT INTERRUPTE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| LM1851 LM1851 Ground Fault Interrupter Literature | LM1851 LM1851 Ground Fault Interrupter Literature Number: SNIS158 LM1851 Ground Fault Interrupter General Description Features The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments Ground fault currents greater than a presettable |
Original | ||||
| magnetic cores for ground fault detectors | ® Division of Spang & Company Technical Bulletin BULLETIN NO. RC-1 MAGNETIC CORES FOR GROUND FAULT DETECTORS GFCI - GFI - GFD -whatever the name is, they all mean sentries of the electric shock. Ground fault circuit interrupters - ground fault interrupters - ground fault detectors |
Original | ||||
| National LM1851 <v Semiconductor LM1851 Ground | National LM1851 <v Semiconductor LM1851 Ground Fault Interrupter General Description Features The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environ ments. Ground fault currents greater than a presettable |
OCR Scan | ||||
| LM1851 National Semiconductor LM1851 Ground Fault | LM1851 National Semiconductor LM1851 Ground Fault Interrupter General Description Features The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environ ments. Ground fault currents greater than a presettable |
OCR Scan | ||||
| LM1851 Ground Fault Interrupter General | LM1851 Ground Fault Interrupter General Description Features The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments Ground fault currents greater than a presettable threshold value will trigger an external SCR-driven circuit |
Original | ||||
| lm1851 | LM1851 Ground Fault Interrupter General Description Features The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments Ground fault currents greater than a presettable threshold value will trigger an external SCR-driven circuit |
Original | ||||
| gm1851 | UNISONIC TECHNOLOGIES CO., LTD GM1851 LINEAR INTEGRATED CIRCUIT GROUND FAULT INTERRUPTER DESCRIPTION The UTC GM1851 can specially provide ground fault protection for AC power outlets in consumer and industrial environments. As ground fault currents greater than a presentable threshold value, it |
Original | ||||
| lm1851 | UTC LM1851 LINEAR INTEGRATED CIRCUIT GROUND FAULT INTERRUPTER DESCRIPTION The UTC LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments. Ground fault currents greater than a presentable threshold value will trigger an external SCR-driven circuit |
Original | ||||
| RV4146 Low Power Ground Fault Interrupter | RV4146 Low Power Ground Fault Interrupter Description Features The RV4146 is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then |
OCR Scan | ||||
| RV4146 RV4146 Low Power Ground Fault Interrupter | RV4146 RV4146 Low Power Ground Fault Interrupter Description Features The RV4146 is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then |
OCR Scan | ||||
| RV4146 RV4146 Low Power Ground Fault Interrupter | RV4146 RV4146 Low Power Ground Fault Interrupter Description Features The RV4146 is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then |
OCR Scan | ||||
| rv4146 | RV4146 RV4146 Low Power Ground Fault Interrupter Description Features The RV4146 is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then |
Original | ||||
| interrupters | RV4141 Low Power Ground Fault Interrupter Description Features The RV4141 Is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then disconnects |
OCR Scan | ||||
| rv4141a | www.fairchildsemi.com RV4141A Low Power Ground Fault Interrupter Features Description • The RV4141A is a low-power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral |
Original | ||||
|
|
||||||
| ground fault interrupter | FAN4147 Ground Fault Interrupter Features Description The FAN4147 is a low-power Ground Fault Interrupter (GFI) controller for detecting hazardous current paths to ground and ground-to-neutral faults. The FAN4147 |
Original | ||||
| rv4141a | www.fairchildsemi.com RV4141A Low Power Ground Fault Interrupter Features Description • The RV4141A is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral |
Original | ||||
| b4E T> m GGGTOfll D7D H R T N RAYTHEON/ | b4E T> m GGGTOfll D7D H R T N RAYTHEON/ SEMICONDUCTOR RV4141 Low Power Ground Fault Interrupter Description Features The RV4141 is a low power controller for AC receptacle ground fault circuit interrupters. These devices detect hazardous current paths to ground and ground to |
OCR Scan | ||||
| RV4141A Low-Power, Ground-Fault Interrupter | RV4141A Low-Power, Ground-Fault Interrupter Features Description The RV4141A is a low-power controller for ACreceptacle, ground-fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then |
Original | ||||
| rv4141a | RV4141A Low-Power, Ground-Fault Interrupter Features Description The RV4141A is a low-power controller for ACreceptacle, ground-fault circuit interrupters. These devices detect hazardous current paths to ground and ground to neutral faults. The circuit interrupter then |
Original | ||||
| fan4147 | FAN4147 Ground Fault Interrupter Features Description The FAN4147 is a low-power Ground Fault Interrupter (GFI) controller for detecting hazardous current paths to ground and ground-to-neutral faults. The FAN4147 application circuit opens the load contacts before a |
Original | ||||