GAS-DISCHARGE VOLTAGE Search Results
GAS-DISCHARGE VOLTAGE Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
TCK22921G |
![]() |
Load Switch IC, 1.1 to 5.5 V, 2.0 A, Reverse current blocking / Auto-discharge, WCSP6E | Datasheet | ||
TCK22946G |
![]() |
Load Switch IC, 1.1 to 5.5 V, 0.4 A, Reverse current blocking / Auto-discharge, WCSP6E | Datasheet | ||
TCK107AF |
![]() |
Load Switch IC, 1.1 to 5.5 V, 1.0 A, Auto-discharge, SOT-25 (SMV) | Datasheet | ||
TCK107AG |
![]() |
Load Switch IC, 1.1 to 5.5 V, 1.0 A, Auto-discharge, WCSP4D | Datasheet | ||
TCK207AN |
![]() |
Load Switch IC, 0.75 to 3.6 V, 2.0 A, Reverse current blocking / Auto-discharge, DFN4A | Datasheet |
GAS-DISCHARGE VOLTAGE Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
CAPSULEContextual Info: LIGHTNING PROTECTORS Gas discharge lightning protector with R445.999.102 gas capsule Gas discharge lightning protector with R445.999.103 gas capsule Gas discharge lightning protector with R445.999.105 gas capsule MODEL R445.G00.004 MODEL R445.G00.005 MODEL |
Original |
||
A 2039
Abstract: A 2039 I 2039 2039 transistor A 2039 equivalent A 2039 g GDT0909
|
Original |
2002/95/EC GDT0909 A 2039 A 2039 I 2039 2039 transistor A 2039 equivalent A 2039 g GDT0909 | |
gas discharge SL1411A
Abstract: PE-80 SL1411A SL1411A075 SL1411A090 SL1411A230 T-940
|
Original |
SL1411A SL1411A 90VDC gas discharge SL1411A PE-80 SL1411A075 SL1411A090 SL1411A230 T-940 | |
GTCX25-XXXM-R02
Abstract: 3POLE GTCX35-XXXM-R05 GTCS36 GTCS23-XXXM-R01-2
|
Original |
||
Contextual Info: Gas Discharge Tubes Gas Discharge Tubes TE Circuit Protection’s GDTs Gas Discharge Tubes are placed in front of, and in parallel with, sensitive telecom equipment such as power lines, communication lines, signal lines and data transmission lines to help protect them from |
Original |
||
GTCA28-272L-R03
Abstract: GTCA28-122M-R03 GTCA28-252M-R03 GTCA28-212M-R03 GTCA28-801M-R05 GTCA28-402M-R03
|
Original |
||
GDT1009Contextual Info: GAS DISCHARGE TUBES Model 2047 Series Heavy Duty Gas Discharge Tube Riverside, California - October 13, 2010 - Bourns GDT Product Line is pleased to announce the release of Bourns® Model 2047 Series heavy duty Gas Discharge Tube GDT . The newly released part numbers are: |
Original |
2002/95/EC GDT1009 GDT1009 | |
GDT 230
Abstract: crowbar GDT0916
|
Original |
2002/95/EC GDT0916 GDT 230 crowbar GDT0916 | |
55A400
Abstract: 55a350 55A90 55A75 55A420 55A470 y1500 gas discharge tube 55A300 C80AL
|
Original |
55A75 55A90 8/20s 10/1000s 00V/s 55A300 55A350 80ALSW, V80AL C80AL 55A400 55a350 55A90 55A75 55A420 55A470 y1500 gas discharge tube 55A300 C80AL | |
2R350
Abstract: 2rm150 2r230 2rm600 WPGT-2SM90 3r230 2N90 470-1000V 3r75 WPGT-2R3000
|
Original |
||
transistor marking 551
Abstract: A551
|
Original |
UL-497B 57845/VDE transistor marking 551 A551 | |
820 marking
Abstract: 662 marking A820 Gas discharge tube
|
Original |
8x20mm 20kA/20A) UL-497B 57845/VDE 820 marking 662 marking A820 Gas discharge tube | |
gas discharge tube
Abstract: 662 marking UL-497B 820 marking A820
|
Original |
8x20mm 20kA/20A) UL-497B 57845/VDE gas discharge tube 662 marking UL-497B 820 marking A820 | |
Contextual Info: Coaxial Arrester ARR Series OUT LINE ARR series protects the device from the surge voltage, utilizing the gas discharge tube. It prevent the surge voltage from circuits of the base station. FEATURES ・ The gas discharge tube is installed. Characteristic Impedance |
Original |
AWG16â | |
|
|||
Contextual Info: GAS DISCHARGE TUBES Bourns Adds High Voltage GDT Products Riverside, California - June 1, 2012 - Bourns is pleased to announce the release of four new series of High Voltage Gas Discharge Tubes GDTs . The new GDT series target industrial applications requiring high |
Original |
2087-xx-X 2093-xxx-SM 2095-xxx-X 2002/95/EC 2011/65/EU GDT1212 | |
662 marking
Abstract: A821
|
Original |
8x20mm 20kA/20A) UL-497B 57845/VDE 662 marking A821 | |
UDN7180A
Abstract: Gas-Discharge Display Segment Driver
|
OCR Scan |
UDN7180A Gas-Discharge Display Segment Driver | |
2RK3000
Abstract: 2RL1400 2RL1000 2RH2500 2RH2500M-8 2RH2000 2RH3000 2RK3500 2RK4000M-8 2RK4000
|
Original |
00V/s 00V/s 2RH3600L-8 2RH3600M-8 2RH2700 2RH2700M-8 2RH3000 2RH3000M-8 2RK3000 2RL1400 2RL1000 2RH2500 2RH2500M-8 2RH2000 2RK3500 2RK4000M-8 2RK4000 | |
Contextual Info: 3-Electrode Gas Discharge Tube GDT PL3E8 Series > Leaded RoHS PL3E8 Series Description Gas discharge Tubes (GDT) are classical components for protecting the installations of the telecommunications. It is essential that IT and telecommunications systems -with their |
Original |
||
17-B2
Abstract: 6176B 2X220 22N-SK 13B2 LAC-2 2x55 SO-239 PD-222 5000Amperes
|
OCR Scan |
SO-239 617-6B 2x617-6B 2x13B2 4x13B2 2X220B 4x220B 2x424B 4x424B 17-B2 6176B 2X220 22N-SK 13B2 LAC-2 2x55 PD-222 5000Amperes | |
Contextual Info: Gas Discharge Tubes GTCX28-XXXM-R20 Series TE Circuit Protection 8mm 2Pole GDTs ceramic gas discharge tubes , are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from damage caused by transient surge voltages that |
Original |
GTCX28-XXXM-R20 SCD27622 | |
Contextual Info: G.D.T. application notes Littelfuse Gas Discharge Tubes G.D.T.s are manufactured using totally non-radioactive processes and are designed to perform to the stated characteristics of ITU (formally CCITT) K12. OPERATION The Gas Discharge Tube (G.D.T.) operates as a voltage dependent switch. When a voltage |
Original |
||
3RM090L-8
Abstract: 3RM090 3RM075L-8 3RM350L-8 gas discharge tube in ac line 3rm090l8 3RM-600L-8
|
Original |
00V/s 3RM600L-8/T 3RM350L-8/T 3RM800L-8/T 3RM090L-8 3RM090 3RM075L-8 3RM350L-8 gas discharge tube in ac line 3rm090l8 3RM-600L-8 | |
Contextual Info: Surface Mount 2-Electrode Gas Discharge Tube GDT PL1210 Series > SMD RoHS PL1210 Series Description Gas discharge Tubes (GDT) are classical components for protecting the installations of the telecommunications. It is essential that IT and telecommunications systems -with their |
Original |
PL1210 1210-XXXBSMD |