GAS SENSOR CATALYST Search Results
GAS SENSOR CATALYST Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| 73725-0010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 73725-1010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 72313-4010BPLF | Amphenol Communications Solutions | USB 2.0, Input Output Connector, Single Deck Receptacle, Type A, Through Hole, Right Angle, 4 Positions with Sensor Contact |
Documents mentioning GAS SENSOR CATALYST
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| an8000 | Application Note AN8000.11 XE8000 Wireless Gas Sensor AN8000.11 Application Note Wireless Gas Sensor Rev 1 February 2006 www.semtech.com 1 Application Note AN8000.11 XE8000 Wireless Gas Sensor Abstract This application note describes a wireless gas sensor module. The application is based on an 8 bit micro controller |
Original | ||||
| microsens | M I C R O S E N S Sensor Description Microsens Semiconductor Gas Sensor • MSGS 3000 Monosensor • MSGS 4000 Multisensor MSGS 3000 Gas sensor mounted on a standard TO type package Miniaturized semiconductor gas sensor are manufactured using standard microelectronic technology |
Original | ||||
| xe8000 | Application Note XE8000 Wireless Gas Sensor ____________________ AN8000.11 Application Note ____________________ Wireless Gas Sensor Author: Reinhard Larch For further information, please contact: XEMICS SA E-mail: info@xemics.com Web: http://www.xemics.com |
Original | ||||
| infrared gas analyzer | INFRARED GAS ANALYZER FOR STACK GAS DATA SHEET ZSU This analyzer consists of an infrared gas analyzer, a zirconia O2 sensor and a gas sampling device. It is used for simultaneous and continuous measurement of the NOX, SO2, CO, CO2 and O2 components in the flue gas of various boilers, garbage incinerators, etc. |
Original | ||||
| infrared gas analyzer | INFRARED GAS ANALYZER FOR STACK GAS DATA SHEET ZSP This instrument consists of an (or two) infrared gas analyzer(s), a zirconia O2 sensor and a sampling device. It is used for measuring the NOx, SO2, CO and O2 components in the flue gas of various boilers, garbage incinerators, furnaces, etc. |
Original | ||||
| tgs2611 | an ISO9001 company TECHNICAL INFORMATION FOR TGS2611 Technical Information for Methane Gas Sensors The Figaro 2600 series is a new type thick film metal oxide semiconductor, screen printed gas sensor which offers miniaturization and lower power consumption. The TGS2611 |
Original | ||||
EasyLine Continuous Gas Analyzers EL3000 Series Models EL3020, EL3040 Data Sheet 10/24 4.10 EN November 2009 Detectors with different measurement principles for Customizable analog outputs, digital inputs and numerous process and emission monitoring |
Original | |||||
| ao2000 | Advance Optima Continuous Gas Analyzers AO2000 Series Models AO2020, AO2040 Data Sheet 10/24 1.20 EN February 2009 One central unit and various analyzer modules Menu-driven operator interface Clear-text status messages Multiple interfaces for communication with host and |
Original | ||||
| infrared gas analyzer | NDIR TYPE INFRARED GAS ANALYZER (5-COMPONENT ANALYZER) DATA SHEET This gas analyzer (ZKJ) is capable of measuring the concentrations of NO, SO 2, CO 2, CO, CH4 and O2 components in sample gas. NO, SO2, CO2, CO and CH4 are measured by non-dispersion infrared method (NDIR), while O 2 is measured by built-in |
Original | ||||
| ngl07 | NGL07 SPECIFICATION Carbon Monoxide Sensor for use within residential CO Detectors 2x2 mm Low Power NGL07 Heater Resistance at 21°C Typical Value 16 ± 3Ω KEY FEATURES Heater Resistance at 405 ± 15°C Typical Value 37.1 ± 7.5 Ω Baseline Sensor Resistance in |
Original | ||||
| ao2000 | Continuous Gas Analyzers AO2000 Series Data Sheet 10/24 1.10 EN July 2007 One central unit and various analyzer modules Menu-driven operator interface Clear-text status messages Multiple interfaces for communication with host and – with common controls |
Original | ||||
| gs05 | GS05 Hydrogen Sulphide Sensor SPECIFICATION 3x3 mm Standard Power GS05 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 475 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| gs22 | GS22 Sulphur Dioxide Sensor SPECIFICATION 3x3 mm Standard Power GS22 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 475 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 25 ± 5 kΩ |
Original | ||||
| gs06 | GS06 Ammonia Sensor SPECIFICATION 3x3 mm Standard Power GS06 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 410 ± 30°C Typical Value 13 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 53 ± 5 kΩ |
Original | ||||
|
|
||||||
| Advance Optima Continuous Gas Analyzers AO2000 | Advance Optima Continuous Gas Analyzers AO2000 Series Software Version 5.0 Operator’s Manual 42/24 10 EN Rev. 9 Advance Optima Continuous Gas Analyzers AO2000 Series Software Version 5.0 Operator’s Manual Publication No. 42/24 10 EN Rev. 9 Edition March 2009 |
Original | ||||
| Always a good solution Overview of process | Always a good solution Overview of process instrumentation and measurement solutions Contents KROHNE trademarks used in this brochure: KROHNE AST CalSys CARGOMASTER Configure it EcoMATE KROHNE Care OPTIBATCH OPTIFLEX OPTIFLUX OPTIMASS OPTISONIC OPTISOUND OPTISWIRL |
Original | ||||
| Always a good solution Overview of process | Always a good solution Overview of process instrumentation and measurement solutions Contents KROHNE trademarks used in this brochure: KROHNE AST CalSys CARGOMASTER Configure it EcoMATE KROHNE Care OPTIBATCH OPTIFLEX OPTIFLUX OPTIMASS OPTISONIC OPTISOUND OPTISWIRL |
Original | ||||
| toluene | AAL25 Toluene Sensor SPECIFICATION 2 x 2 mm Low Power AAS25 Heater Resistance at 21°C KEY FEATURES Typical Value 16 ± 3Ω Fast response • Heater Resistance at 380 ± 30°C Typical Value 37.1 ± 7.5Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| cts04 | CTS04 Butane Sensor SPECIFICATION 3x3 mm Standard Power CTS04 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 475 ± 20°C Typical Value 15 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 25 ± 5 kΩ |
Original | ||||
| lgs09 | LGS09 Chlorine Sensor SPECIFICATION 3x3 mm Standard Power LGS09 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 400 ± 20°C Typical Value 13 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 2kΩ |
Original | ||||
| aas13 | AAS13 Methanol Sensor SPECIFICATION 3x3 mm Standard Power AAS13 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 410 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 75 ± 5 kΩ |
Original | ||||
| cts23 | CTS23 Hydrogen Sensor SPECIFICATION 3x3 mm Standard Power CTS23 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 380 ± 30°C Typical Value 12 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 85 ± 5 kΩ |
Original | ||||
| aas14 | AAS14 Ethanol Sensor SPECIFICATION 3x3 mm Standard Power AAS14 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 385 ± 30°C Typical Value 12 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 85kΩ |
Original | ||||
| aas20 | AAS20 Iso Propyl Alcohol Sensor SPECIFICATION 3x3 mm Standard Power AAS20 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 380 ± 30°C Typical Value 12 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| lgs10 | LGS10 Nitrogen Dioxide Sensor SPECIFICATION 3x3 mm Standard Power LGS10 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 410 ± 30°C Typical Value 12 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||