Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FUJI CONTACTOR Search Results

    FUJI CONTACTOR Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    DRV3946QPWPRQ1
    Texas Instruments Automotive 12-V contactor driver with current sensing and regulation 28-HTSSOP -40 to 125 Visit Texas Instruments

    Documents mentioning FUJI CONTACTOR

    Document Partial File Text Tags Type PDF
    gei-100364c
    GEI-100364C Supersedes GEI-100364B GE Fuji Drives USA AF-300 P11 User’s Guide ™ © 1999, 2000 by GE Fuji Drives USA, Inc. All rights reserved. These instructions do not purport to cover all details or variations in equipment, nor to provide every possible
    Original PDF
    fuji igbt
    Quality is our message FUJI IGBT–IPM APPLICATION MANUAL Sep. 2004 REH983a CONTENTS Chapter 1 Features 1. GBT-IPMs Characteristics…1-2 2. IPM Characteristics by Series…1-4
    Original PDF
    2
    Quality is our message FUJI IGBT MODULES APPLICATION MANUAL February 2004 REH984 CONTENTS Chapter 1 Structure and Features 1. Structure and features… 1-3 2. FUJI's IGBTs… 1-4
    Original PDF
    Magnetic Contactors and Starters General
    Magnetic Contactors and Starters General information 01 FUJI low-voltage contactors and starters are available in a broad choice of types, from high-performance to economy, for all consumer and industrial needs. For standard applications, we offer the highperformance SC series. We offer the
    Original PDF
    High Performance Multifunctional Inverters
    High Performance Multifunctional Inverters Maximum Engineering for Global Advantage FUJI INVERTERS With the flexibility and functionality to support a wide range of applications on all types of mechanical equipment, the FRENIC-MEGA takes core capability, responsiveness, environmental awareness, and
    Original PDF
    rc310
    Cam Type RC310 Control selector switches Cam-type control selector switches ■ Description FUJI cam-type control switches are recommended for use on switchboards, control panels and switchgear because of their reliability in service. The main type is RC310 with operational current
    Original PDF
    rc310
    Cam Type RC310 Control selector switches Cam-type control selector switches ■ Description FUJI cam-type control switches are recommended for use on switchboards, control panels and switchgear because of their reliability in service. The main type is RC310 with operational current
    Original PDF
    k244
    Limit Switches General information Limit switches, AL and K244 series ■ Description FUJI AL and K244 series limit switches have wide application in such industrial equipment as machine tools, printing machines, and transfer machines. These switches feature a sturdy aluminum diecast housing that is highly resistant to oil,
    Original PDF
    03 Individual catalog No. LOW VOLTAGE PRODUCTS Up
    03 Individual catalog No. LOW VOLTAGE PRODUCTS Up to 600 Volts 01 Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors 02 Manual Motor Starters and Contactors Combination Starters 03 Industrial Relays, Industrial Control Relays
    Original PDF
    Industrial Control Relays Relays–and–terminal
    Industrial Control Relays Relays–and–terminal module RS type Relays-and-terminal module RS4„, 6N • A very compact, space-saving terminal module containing four or six relays with one NO contact. ■ Features • The RS series relays-and-terminal module consists of four or six plug-in
    Original PDF
    Vol. 16 New Products Low Voltage Air Circuit
    Vol. 16 New Products Low Voltage Air Circuit Breakers (ACB) DW Series… 2 Molded Case Circuit Breakers BX Series… 6
    Original PDF
    qc06e
    Power Factor Controllers Automatic power factor regulators QC06E and QC12E Automatic power factor regulator QC06E, QC12E ■ Description Automatic power factor regulator (APFR) is a device which is designed to maintain the target power factor by regulating
    Original PDF
    Industrial Relays SH series General information
    Industrial Relays SH series General information Bifurcated contacts with excellent electrical conductivity/SH-4, SH-5 ■ Description SH series industrial relays are designed to increase contact reliability and make them easy to use. The relays' highly reliable, bifurcated
    Original PDF
    contactor
    "MICRO LINE" AC Contactors & Starters, DC Operated FEATURES CAN BE DIRECTLY DRIVEN BY TRANSISTOR OUTPUT OF PROGRAMMABLE LOGIC CONTROLLER (PLC) Direct driving by DC output of programmable logic controller (PLC) or other electronic equipment. The power consumption of the SJ-0G contactor
    Original PDF
    Z SERIES FUZZY CONTROLLER X (48)96, 96)96mm)
    Z SERIES FUZZY CONTROLLER X (48)96, 96)96mm) PYX5,9 DATA SHEET The PYX is a state-the-art temperature controller offering enhanced control through the use of fuzzy logic. By employing fuzzy logic the PYX virtually eliminates system overshoot and effectively supresses fluctuation of the
    Original PDF
    fuzzy controller
    Z SERIES FUZZY CONTROLLER X (48)48mm) PYX4 DATA SHEET The PYX is a state-the-art temperature controller offering enhanced control through the use of fuzzy logic. By employing fuzzy logic the PYX virtually eliminates system overshoot and effectively supresses fluctuation of the
    Original PDF
    New Product Single-phase Power Controller G3PW
    New Product Single-phase Power Controller G3PW High-precision Control with Easy Setup • Precise heater burnout detection. • Set value and present value monitoring with indicators. • Phase control or optimum cycle control. • RS-485 communications to set manipulated variables and
    Original PDF
    inverter 3g3pv
    SYSDrive Frequency Inverter 3G3PV T V/f control T PID control T Standard LED, optional LCD operator T Fieldbus options: DeviceNet T 7 configurable digital inputs T 3 configurable digital outputs T Low audible noise T Powerful application oriented functionality
    Original PDF
    i533-e1-01
    Cat. No. I533-E1-01 USER’S MANUAL SMARTSTEP A SERIES MODELS R7M-A@ (Servomotors) R7D-AP@ (Servo Drivers) Servomotors/Servo Drivers Thank you for choosing this SMARTSTEP A-series product. Proper use and handling of the product will ensure proper product performance, will lengthen
    Original PDF
    INDEX GENERAL INFO Pages Sales Terms / Shipping…
    INDEX GENERAL INFO Pages Sales Terms / Shipping… 2 Fan Applications… 3-5 Using This Catalog… 6 Index & Multipliers… 67 FANS & MOTOR REPAIR PARTS CATALOG SERIES 1 – SHALLOW RECESS PAGES 7-12 SERIES 2 – PADDLE WHEEL
    Original PDF
    Cat. No. I533-E1-04 SMARTSTEP A SERIES R7M-A@
    Cat. No. I533-E1-04 SMARTSTEP A SERIES R7M-A@ (Servomotors) R7D-AP@ (Servo Drivers) Servomotors/Servo Drivers USER’S MANUAL Thank you for choosing this SMARTSTEP A-series product. Proper use and handling of the product will ensure proper product performance, will lengthen product life, and
    Original PDF
    CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar
    CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar Support Power Supply MCB Bar Contactor / Thermal Overload Relay / Auxiliary Contact Terminal Block Din Rail Terminal Block C/W Cover Terminal Block Float Switch Foot Switch Warning Light / Tower Light Hour Run Meter / Time Switch / Weather Proof Isolating Switch
    Original PDF
    MODEL CONFIGURATION PXZ SERIES 1 P X Z Operation
    MODEL CONFIGURATION PXZ SERIES 1 P X Z Operation Manual PID Autotune Controllers Featuring Fuzzy Logic Front panel size 1/16 DIN 1/8 DIN 72mm 1/4 DIN Code 4 5 7 9 Kinds of input Thermocouple (°C) Thermocouple (°F) RTD/Pt100 (°C) RTD/Pt100 (°F) 4-20mA DC, 1-5V DC
    Original PDF
    USER’S MANUAL OMNUC U SERIES MODELS R88M-U_ (AC
    USER’S MANUAL OMNUC U SERIES MODELS R88M-U_ (AC Servo Motors) MODELS R88D-UT_ (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kW) Thank you for choosing this OMNUC U-series product. Proper use and handling of the product will ensure proper product performance, will length product life, and
    Original PDF
    Operating Instructions Bedienungsanleitung
    Operating Instructions Bedienungsanleitung Instructions de Service PTB No. 00 ATEX 2129 X Device with II 2G/D EEx m and II 2G EEx em-approval Example: Type 6013 Geräte mit II 2G/D EEx m bzw. II 2G EEx em-Zulassung Beispiel: Type 6013 Appareils avec mode de protection
    Original PDF