FU2 AXICOM Search Results
Documents mentioning FU2 AXICOM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| AXICOM Telecom-, Signal and RF Relays FT2/FU2 | AXICOM Telecom-, Signal and RF Relays FT2/FU2 Relay 108-98004 • Apr. 10 Rev. H • ECOC: JM10 AXICOM 108-98004 Rev. H Telecom-, Signal and RF Relays FT2/FU2 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| axicom | AXICOM Telecom-, Signal and RF Relays FT2/FU2 Relay 108-98004 • Nov. 07 Rev. F • ECOC: JM10 AXICOM 108-98004 Rev. F Telecom-, Signal and RF Relays FT2/FU2 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| AXICOM Telecom-, Signal and RF Relays FT2/FU2 | AXICOM Telecom-, Signal and RF Relays FT2/FU2 Relay 108-98004 • Sep. 08 Rev. G • ECOC: JM10 AXICOM 108-98004 Rev. G Telecom-, Signal and RF Relays FT2/FU2 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| The Best Relaytion FT2 / FU2 Relay FT2 / FU2 | The Best Relaytion FT2 / FU2 Relay FT2 / FU2 Relay 2 pole telecom/signal relay Through Hole Type (THT) Non – polarized. non-latching 1 coil Features – Telecom/signal relay (dry circuit, test access, ringing) Slim line 15 x 7.5 mm, 0.59 x 0.295 inch |
Original | ||||
| e111441 | The Best Relaytion FT2 / FU2 Relay FT2 / FU2 Relay 2 pole telecom/signal relay Through Hole Type (THT) Non – polarized. non-latching 1 coil File No. E111441 UL 508 UL 60950 Features – CECC 61811-54-001 Telecom/signal relay (dry circuit, test access, ringing) |
Original | ||||
| Signal Relays AXICOM FT2/FU2 Relay n | Signal Relays AXICOM FT2/FU2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 15x7.5mm (.59x.295”) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitive 24V and 48V coil versions n Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V |
Original | ||||
| Signal Relays AXICOM FT2/FU2 Relay n | Signal Relays AXICOM FT2/FU2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 15x7.5mm (.59x.295”) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitive 24V and 48V coil versions n Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V |
Original | ||||
| Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) | Catalog 1308242 Issued 3-03 (PDF Rev. 4-04) AXICOM FT2/FU2 series DPDT Slim Package Telecom/Signal PC Board Relays File E111441 File 176679-1079886 16504-002 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of |
Original | ||||
| Signal Relays Axicom FT2/FU2 Relay n | Signal Relays Axicom FT2/FU2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 15x7.5mm (.59x.295”) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitive 24V and 48V coil versions n Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V |
Original | ||||
| Signal Relays AXICOM FT2/FU2 Relay n | Signal Relays AXICOM FT2/FU2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 15x7.5mm (.59x.295”) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitive 24V and 48V coil versions n Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V |
Original | ||||
| mt relay | MT2 / MT4 MT relay light duty dual-in-line MT-Relais für Schwachstrom Dual-in-line Le relais MT: un relais dual-in-line pour courant faible Introduction The MT relay is a dual-in-line relay with two or four change-over contacts, respectively, and a low power consumption. It is particularly |
Original | ||||
| Signal Relays AXICOM P2 Relay V23079 n Standard | Signal Relays AXICOM P2 Relay V23079 n Standard telecom relay (ringing and test access) line 15x7.5mm (.590x.295”) n Max. switching current 5A n 2 form C bifurcated contacts (2 changeover contacts, 2 CO) n Immersion cleanable n High sensitivity for low power consumption 140mW/ 70mW |
Original | ||||
| v23079 | Signal Relays AXICOM P2 Relay V23079 n Standard telecom relay (ringing and test access) line 15x7.5mm (.590x.295”) n Max. switching current 5A n 2 form C bifurcated contacts (2 changeover contacts, 2 CO) n Immersion cleanable n High sensitivity for low power consumption 140mW/ 70mW |
Original | ||||
| AXICOM Telecom-, Signal and RF Relays Cradle | AXICOM Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting 108-98016 • Nov. 07 • Rev. C • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98016 Rev. C Cradle Relay Accessories and Mounting Disclaimer While Tyco Electronics has made every reasonable effort |
Original | ||||
|
|
||||||
| axicom | AXICOM Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting 108-98012 • Nov. 07 • Rev. C • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98012 Rev. C Cradle Relay Accessories and Mounting Disclaimer While Tyco Electronics has made every reasonable effort |
Original | ||||
| AXICOM Telecom-, Signal and RF Relays Cradle | AXICOM Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting 108-98016 • Apr. 10 • Rev. D • ECOC: JM10 AXICOM 108-98016 Rev. D Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting Disclaimer While Tyco Electronics has made every reasonable effort |
Original | ||||
| v23105 | AXICOM Telecom-, Signal and RF Relays 108-98007 Rev A D2n V23105 Relay 2 pole telecom relay, non-polarized, Through Hole Type (THT) Relay types: non-latching with 1 coil ROHS compliant (Directive 2002/95/EC) as per product date code 0418. Features • Standard DIL relay |
Original | ||||
| axicom | AXICOM Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting 108-98016 • Nov. 07 • Rev. C • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98016 Rev. C Cradle Relay Accessories and Mounting Disclaimer While Tyco Electronics has made every reasonable effort |
Original | ||||
| AXICOM Telecom-, Signal and RF Relays HF6 Relay | AXICOM Telecom-, Signal and RF Relays HF6 Relay 108-98022 • Nov. 07 Rev. A • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98022 HF6 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||