FLUID SEN Search Results
FLUID SEN Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| 73725-0010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 73725-1010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 72313-4010BPLF | Amphenol Communications Solutions | USB 2.0, Input Output Connector, Single Deck Receptacle, Type A, Through Hole, Right Angle, 4 Positions with Sensor Contact |
Documents mentioning FLUID SEN
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| senso | MultiMulti-Point Hot Fluid Level Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction There are several laboratory fluid systems that required fluid level monitoring to help control very elaborate equipment processes. This new float sensor has four sensing positions, three of which are dedicated to monitoring hot fluid |
Original | ||||
| capacitive | Capacitive sensors ensure precise fluid-level measurements with greater accuracy and lower set-up costs, utilizing customized end-to-end solutions and easyto-install calibration software Capacitive Fluid Level Sensors Capacitive Fluid Level Sensors easily mount to the outside of a container and |
Original | ||||
| Product Information 3M™ Novec™ 7000 Engineered | Product Information 3M™ Novec™ 7000 Engineered Fluid Introduction 3M™ Novec™ 7000 Engineered Fluid, 1-methoxyheptafluoropropane, is a non-flammable, low global warming potential (GWP) heat transfer fluid capable of reaching -120°C. It is also useful as a direct |
Original | ||||
| pn-12110215tc-12 | Continuous Fluid Level Sensor PN-12110215TC-12 eTape TM Description The eTape sensor is a solid state, continuous (multi-level) fluid level sensor for measuring levels in water, non-corrosive water based liquids and dry fluids (powders). The eTape sensor is |
Original | ||||
| COOLANT/FLUID Sensors L E A ED S S S E AL E D | COOLANT/FLUID Sensors L E A ED S S S E AL E D DESCRIPTION Coolant/Fluid temperature sensors are continuous function devices that change resistance inversely proportional to temperature. These brass sensors consist of five major components: the brass shell, thermal grease, |
Original | ||||
| pn-12110215tc-x-tj | Chemical Fluid Level Sensor PN-12110215TC-X-TJ eTape TM Description The eTape chemical sensor is a solid state, continuous (multi-level) fluid level sensor with a Teflon (FEP) jacket that is rated for use in chemical, petroleum and food safe applications. The eTape |
Original | ||||
| isopropanol | UTFÄRDANDEDATUM: SEPTEMBER 2005 SÄKERHETSDATABLAD ISOPROPANOL CLEANING FLUID 1 NAMNET PÅ PRODUKTEN OCH FÖRETAGET PRODUKTNAMN ISOPROPANOL CLEANING FLUID PRODUKTNR. EIPA01L/ 05L LEVERANTÖR ELECTROLUBE. A division of HK WENTWORTH LTD KINGSBURY PARK, MIDLAND ROAD |
Original | ||||
| accustar | AccuStar Fluid Level Sensors DESCRIPTION Engineering Principle Major components of the AccuStar Fluid Level Sensor are the housing, float, springs, a samarium cobalt magnet, and the Hall Effect sensor. The springs attach the float to the outside housing through three helical leaves. The |
Original | ||||
| lm903 | February 1995 Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or |
OCR Scan | ||||
| Semiconductor February 1995 LM1042 Fluid Level | Semiconductor February 1995 LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is pro vided proportional to fluid level and single shot or repeating |
OCR Scan | ||||
| lm1830 | LM1830 National & Semiconductor LM1830 Fluid Detector G eneral Description Features The LM1830 is a monolithic bipolar integrated circuit de signed for use in fluid detection systems. The circuit is ideal for detecting the presence, absence, or level of water, or |
OCR Scan | ||||
| Pneumatic logic components www.crouzet.com 41 | Pneumatic logic components www.crouzet.com 41 General characteristics Operating fluid - Compressed air or inert gas. flow graphs Conditions of use - Operating pressure 2 at 8 bars (except for special conditions). - Fluid: Filtered air to 50 microns - non lubricated. |
Original | ||||
| inclinometer | Inclinometer NS-10/AAL2-UFG Function principle: This biaxial inclination sensor uses two pieces of basic cells. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. By tilting the sensor, the fluid level over the different |
Original | ||||
| lm903 | LM903 National Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or |
OCR Scan | ||||
|
|
||||||
| lm903 | February 1995 Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or |
OCR Scan | ||||
| lm903 | LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids A low fluid level is indicated by a warning lamp operating in continuous or flashing mode All supervisory requirements to control the |
Original | ||||
| lm1830 | LM1830 Fluid Detector General Description Features The LM1830 is a monolithic bipolar integrated circuit designed for use in fluid detection systems The circuit is ideal for detecting the presence absence or level of water or other polar liquids An AC signal is passed through two |
Original | ||||
| aal2-ucd | Inclinometer NS-2/AAL2-UCD Function principle: This biaxial inclination sensor uses 2 pieces of basic cells. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. By tilting the sensor, the fluid level over the different |
Original | ||||
| Piezoresistive Accelerometer ENDEVCO Model 2262A | Piezoresistive Accelerometer ENDEVCO Model 2262A MODEL 2262A • Rugged, Fluid Damped DC Response 1000 g and 2000 g Full Scale 500 mV Full Scale Output Hermetically Sealed DESCRIPTION Actual size The ENDEVCO® Model 2262A accelerometers are rugged, fluid damped transducers of the |
Original | ||||
| endevco | Piezoresistive Accelerometer ENDEVCO Model 2262A MODEL 2262A • Rugged, Fluid Damped DC Response 25 to 2000 g Full Scale 500 mV Full Scale Output Hermetically Sealed DESCRIPTION Actual size The ENDEVCO® Model 2262A accelerometers are rugged, fluid damped transducers of the |
Original | ||||
| endevco | Piezoresistive Accelerometer ENDEVCO Model 2262CA MODEL 2262CA • Rugged, Fluid Damped DC Response 25 to 2000 g Full Scale Six Wire System For Shunt Calibration • Hermetically Sealed Actual size DESCRIPTION The ENDEVCO® Model 2262CA accelerometers are rugged, fluid damped transducers of the |
Original | ||||
| lm1042 | LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids An output is provided proportional to fluid level and single shot or repeating measurements may be made All supervisory requirements |