Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FLUID LEVEL CIRCUIT Search Results

    FLUID LEVEL CIRCUIT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TC7MP3125FT
    Toshiba Electronic Devices & Storage Corporation Level shifter, Bidirectional, 2-Bit x 2 Dual Supply Bus Transceiver, TSSOP16B, -40 to 85 degC Datasheet
    74LV4T126FK
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC Datasheet
    74LV4T125FK
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC Datasheet
    7UL1T04NX
    Toshiba Electronic Devices & Storage Corporation One-Gate Logic(L-MOS), Inverter with Level Shifting, XSON6, -40 to 125 degC Datasheet
    74LV4T126FT
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, TSSOP14, -40 to 125 degC, AEC-Q100 Datasheet

    Documents mentioning FLUID LEVEL CIRCUIT

    Document Partial File Text Tags Type PDF
    senso
    MultiMulti-Point Hot Fluid Level Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction There are several laboratory fluid systems that required fluid level monitoring to help control very elaborate equipment processes. This new float sensor has four sensing positions, three of which are dedicated to monitoring hot fluid
    Original PDF
    capacitive
    Capacitive sensors ensure precise fluid-level measurements with greater accuracy and lower set-up costs, utilizing customized end-to-end solutions and easyto-install calibration software Capacitive Fluid Level Sensors Capacitive Fluid Level Sensors easily mount to the outside of a container and
    Original PDF
    lm903
    February 1995 Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or
    OCR Scan PDF
    Semiconductor February 1995 LM1042 Fluid Level
    Semiconductor February 1995 LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is pro­ vided proportional to fluid level and single shot or repeating
    OCR Scan PDF
    pn-12110215tc-12
    Continuous Fluid Level Sensor PN-12110215TC-12 eTape TM Description The eTape sensor is a solid state, continuous (multi-level) fluid level sensor for measuring levels in water, non-corrosive water based liquids and dry fluids (powders). The eTape sensor is
    Original PDF
    lm903
    LM903 National Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or
    OCR Scan PDF
    lm903
    February 1995 Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or
    OCR Scan PDF
    lm903
    LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids A low fluid level is indicated by a warning lamp operating in continuous or flashing mode All supervisory requirements to control the
    Original PDF
    pn-12110215tc-x-tj
    Chemical Fluid Level Sensor PN-12110215TC-X-TJ eTape TM Description The eTape chemical sensor is a solid state, continuous (multi-level) fluid level sensor with a Teflon (FEP) jacket that is rated for use in chemical, petroleum and food safe applications. The eTape
    Original PDF
    lm1042
    LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids An output is provided proportional to fluid level and single shot or repeating measurements may be made All supervisory requirements
    Original PDF
    Semiconductor LM1042 Fluid Level Detector General
    Semiconductor LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is pro­ vided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements
    OCR Scan PDF
    accustar
    AccuStar Fluid Level Sensors DESCRIPTION Engineering Principle Major components of the AccuStar Fluid Level Sensor are the housing, float, springs, a samarium cobalt magnet, and the Hall Effect sensor. The springs attach the float to the outside housing through three helical leaves. The
    Original PDF
    lm1830
    LM1830 National & Semiconductor LM1830 Fluid Detector G eneral Description Features The LM1830 is a monolithic bipolar integrated circuit de­ signed for use in fluid detection systems. The circuit is ideal for detecting the presence, absence, or level of water, or
    OCR Scan PDF
    lm1830
    LM1830 Fluid Detector General Description Features The LM1830 is a monolithic bipolar integrated circuit designed for use in fluid detection systems The circuit is ideal for detecting the presence absence or level of water or other polar liquids An AC signal is passed through two
    Original PDF
    brake fluid
    Brake Fluid Level Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction When applying one’s foot to the brake pedal, it is taken for granted that the braking mechanism will begin to slow or stop the vehicle. A hermetically sealed reed switch plays a key reliability role by monitoring that the brake fluid level is
    Original PDF
    inclinometer
    Inclinometer NS-10/AAL2-UFG Function principle: This biaxial inclination sensor uses two pieces of basic cells. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. By tilting the sensor, the fluid level over the different
    Original PDF
    aal2-ucd
    Inclinometer NS-2/AAL2-UCD Function principle: This biaxial inclination sensor uses 2 pieces of basic cells. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. By tilting the sensor, the fluid level over the different
    Original PDF
    cls-1200
    LEVEL SWITCHES Solid State Level Sensors - CLS-1200 SOLID STATE CLS-1200 Series Conductance Type Level Sensors are the Modern Solution for Nightmare Fluid Monitoring Applications Ī No Moving Parts Integral Electronic Switching 172 bar Max. Pressure
    Original PDF
    ns-25
    Inclination sensor NS-25/C2 Low cost, Tilt Sensor Theory of Operation: The NS-25/C2 is a biaxial, tilt sensor. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. When the sensor is tilted, the fluid level
    Original PDF
    capacitive level sensor
    Capacitive Level Sensor TLB-KSR Easy-to Use Capacitive Level Sensor with Built-in Power Supply Level Controllers • Ideal for sensing powder, grain, or viscous fluid. • High switching capacity: 10 A, 230 VAC. • Sensitivity adjuster and HIGH/LOW selector switch provided.
    Original PDF
    gems
    Silver Bullet™ Liquid Level Sensors Gems Silver Bullet™ liquid level sensors offer unequaled dependability and longevity in a wide range of demanding fluid monitoring applications. These compact, solid-state sensors have no moving parts and are free from maintenance
    Original PDF
    Model LL-V Vertical Entry Liquid Level Sensor
    Model LL-V Vertical Entry Liquid Level Sensor DESCRIPTION The Model LL-V Liquid Level Sensor is designed for vertical en- ible conduit. The electrical cable is vulcanized to a welded-on try into a tank or stilling well for complete submersion in the fluid.
    Original PDF