Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FLUID LEV Search Results

    FLUID LEV Result Highlights (3)

    Part ECAD Model Manufacturer Description Download Buy
    BQ29400DCT3
    Texas Instruments 2nd-Level Overvoltage Protection for 2, 3, or 4 Cell LiIon & LiPoly Batteries (2nd Lev Protection) 8-SM8 Visit Texas Instruments Buy
    BQ29400DCT3E6
    Texas Instruments 2nd-Level Overvoltage Protection for 2, 3, or 4 Cell LiIon & LiPoly Batteries (2nd Lev Protection) 8-SM8 Visit Texas Instruments Buy
    BQ29400PW
    Texas Instruments 2nd-Level Overvoltage Protection for 2, 3, or 4 Cell LiIon & LiPoly Batteries (2nd Lev Protection) 8-TSSOP -25 to 85 Visit Texas Instruments Buy

    Documents mentioning FLUID LEV

    Document Partial File Text Tags Type PDF
    senso
    MultiMulti-Point Hot Fluid Level Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction There are several laboratory fluid systems that required fluid level monitoring to help control very elaborate equipment processes. This new float sensor has four sensing positions, three of which are dedicated to monitoring hot fluid
    Original PDF
    capacitive
    Capacitive sensors ensure precise fluid-level measurements with greater accuracy and lower set-up costs, utilizing customized end-to-end solutions and easyto-install calibration software Capacitive Fluid Level Sensors Capacitive Fluid Level Sensors easily mount to the outside of a container and
    Original PDF
    FLUID PERFORMANCE SPECIFICATIONS FOR DIRECT DRIVE
    FLUID PERFORMANCE SPECIFICATIONS FOR DIRECT DRIVE LCDs Hamlin offers four grades of liquid crystal LC fluid for use in a wide variety of applications — Type 2: A wide temperature fluid with enhanced speed of response at extremely low temperatures. Type 7: An extremely wide temperature range fluid ( - 3 0 ° C
    OCR Scan PDF
    Product Information 3M™ Novec™ 7000 Engineered
    Product Information 3M™ Novec™ 7000 Engineered Fluid Introduction 3M™ Novec™ 7000 Engineered Fluid, 1-methoxyheptafluoropropane, is a non-flammable, low global warming potential (GWP) heat transfer fluid capable of reaching -120°C. It is also useful as a direct
    Original PDF
    isopropanol
    UTFÄRDANDEDATUM: SEPTEMBER 2005 SÄKERHETSDATABLAD ISOPROPANOL CLEANING FLUID 1 NAMNET PÅ PRODUKTEN OCH FÖRETAGET PRODUKTNAMN ISOPROPANOL CLEANING FLUID PRODUKTNR. EIPA01L/ 05L LEVERANTÖR ELECTROLUBE. A division of HK WENTWORTH LTD KINGSBURY PARK, MIDLAND ROAD
    Original PDF
    lm903
    February 1995 Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or
    OCR Scan PDF
    Semiconductor February 1995 LM1042 Fluid Level
    Semiconductor February 1995 LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is pro­ vided proportional to fluid level and single shot or repeating
    OCR Scan PDF
    pn-12110215tc-12
    Continuous Fluid Level Sensor PN-12110215TC-12 eTape TM Description The eTape sensor is a solid state, continuous (multi-level) fluid level sensor for measuring levels in water, non-corrosive water based liquids and dry fluids (powders). The eTape sensor is
    Original PDF
    lm1830
    LM1830 National & Semiconductor LM1830 Fluid Detector G eneral Description Features The LM1830 is a monolithic bipolar integrated circuit de­ signed for use in fluid detection systems. The circuit is ideal for detecting the presence, absence, or level of water, or
    OCR Scan PDF
    lm903
    LM903 National Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or
    OCR Scan PDF
    lm903
    February 1995 Semiconductor LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids. A low fluid level is indicated by a warning lamp operating in continuous or
    OCR Scan PDF
    lm903
    LM903 Fluid Level Detector General Description Features The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids A low fluid level is indicated by a warning lamp operating in continuous or flashing mode All supervisory requirements to control the
    Original PDF
    pn-12110215tc-x-tj
    Chemical Fluid Level Sensor PN-12110215TC-X-TJ eTape TM Description The eTape chemical sensor is a solid state, continuous (multi-level) fluid level sensor with a Teflon (FEP) jacket that is rated for use in chemical, petroleum and food safe applications. The eTape
    Original PDF
    lm1830
    LM1830 Fluid Detector General Description Features The LM1830 is a monolithic bipolar integrated circuit designed for use in fluid detection systems The circuit is ideal for detecting the presence absence or level of water or other polar liquids An AC signal is passed through two
    Original PDF
    lm1042
    LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids An output is provided proportional to fluid level and single shot or repeating measurements may be made All supervisory requirements
    Original PDF
    accustar
    AccuStar Fluid Level Sensors DESCRIPTION Engineering Principle Major components of the AccuStar Fluid Level Sensor are the housing, float, springs, a samarium cobalt magnet, and the Hall Effect sensor. The springs attach the float to the outside housing through three helical leaves. The
    Original PDF
    Semiconductor LM1042 Fluid Level Detector General
    Semiconductor LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is pro­ vided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements
    OCR Scan PDF
    inclinometer
    Inclinometer NS-10/AAL2-UFG Function principle: This biaxial inclination sensor uses two pieces of basic cells. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. By tilting the sensor, the fluid level over the different
    Original PDF
    vm200
    2/3 Port Mechanical Valve Series VM200 Large flow capacity. A variety of actuator types. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Weight (Basic) Air/Inert gas 0 to 1.0 MPa –5 to 60°C (No freezing)
    Original PDF
    dft-100
    SSI Technologies – Application Note DT-AN1 Digital Fluid-Trac™ (Model DFT-100) Ultrasonic Drum Level Gauge Product Overview Product Description Digital Fluid-Trac™ (Model DFT-100) drum level gauge is a cost competitive non-contact continuous liquid level drum gauge. It is designed for use on vertical
    Original PDF
    Digital Fluid-Trac Ultrasonic Drum Level Gauge
    Digital Fluid-Trac Ultrasonic Drum Level Gauge NEW! Description: This drum level gauge is a cost competitive non-contact continuous liquid level drum gauge. Designed for use on vertical drums storing a wide variety of media such as water, waste water, motor oil, hydraulic fluid and diesel
    Original PDF
    aal2-ucd
    Inclinometer NS-2/AAL2-UCD Function principle: This biaxial inclination sensor uses 2 pieces of basic cells. The sensor works in the way that an electrolytical fluid is formed out by applying an AC-voltage on the planar electrode structures. By tilting the sensor, the fluid level over the different
    Original PDF