Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FLOWMETERS 46 Search Results

    Documents mentioning FLOWMETERS 46

    Document Partial File Text Tags Type PDF
    mt3809g
    Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG December, 2014 Models MT3809G & MT3810G Brooks® Models MT3809G and MT3810G Metal Tube Variable Area Flowmeters Model MT3809G General Purpose Housing Model MT3809G Model MT3809G
    Original PDF
    d184s073u02
    Data Sheet D184S073U02 Electromagnetic Flowmeter FSM4000 Pos: 1 /Titelblätter / Copyright/DB/Durchfluss/FSM4000 @ 34\mod_1259573431187_3101.doc @ 310891 @ Function - Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries,
    Original PDF
    ECONOMICAL BALL BEARING GAS TURBINE FLOWMETERS
    ECONOMICAL BALL BEARING GAS TURBINE FLOWMETERS with Male NPT Fittings $ 725 MADE IN USA NIST Basic Unit ߜ ±1% of Reading Accuracy ߜ Ball Bearing Design for Economy ߜ 440C Bearing Retainers for Durability ߜ Ball Bearings Field Replaceable Without Loss of Calibration
    Original PDF
    ECONOMICAL BALL BEARING TURBINE FLOWMETERS With
    ECONOMICAL BALL BEARING TURBINE FLOWMETERS With 37° Flare Fittings From $ 1099 MADE IN USA ߜ ±1⁄2% of Reading Accuracy ߜ Ball Bearing Design for Economy ߜ Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life OMEGA® FTB-200 Series turbine
    Original PDF
    Flowmeters & Monitors Dataflow Compact - Inline
    Flowmeters & Monitors Dataflow Compact - Inline Flow Transmitter Features & Benefits Pulse output signal for flows up to 25 l/min. Lightweight and robust. Operates in any plane. Simple to install. Low cost flow measurement. Negligible pressure drop. Accepts reverse flow.
    Original PDF
    DS-VA-GT1000-eng August , 2014 Data Sheet Glass
    DS-VA-GT1000-eng August , 2014 Data Sheet Glass Tube Flowmeter Model GT1000 Model GT1020 Model GT1024 Variable Area Industrial Glass Tube, Variable Area Flowmeters Description The Brooks® GT 1000 combines ruggedness and simplicity in design to provide a versatile
    Original PDF
    d184s073u02
    Data Sheet D184S073U02 Level 0: Information ■ Function – Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, pastes and sludges with an electrical conductivity of at least 20 µS/cm (opt. 0.5 µS/cm). ■ Applications
    Original PDF
    VARIABLE AREA FLOWMETERS Flow Reference Section
    VARIABLE AREA FLOWMETERS Flow Reference Section Retaining Ring End Cap Body Flow Indicator Dust Guard Scale Assembly Seal Bumper Flow End Fitting Spider Plate Metering Cone Figure 4: Piston-type Variable Area Flowmeter 1 3 5 Magnet/ Piston Assembly A. INLET PORT
    Original PDF
    VORTEX FLOWMETERS MADE IN USA $ 1752 Basic Unit
    VORTEX FLOWMETERS MADE IN USA $ 1752 Basic Unit FV-520B-F-D, shown smaller than actual size ߜ Measures Steam, Gas, and Low Viscosity Liquids ߜ No Moving Parts and No Sensor Contact with Process Fluid ߜ Accuracy Up to 0.8% of Rate ߜ Intelligent Amplifier
    Original PDF
    DS-VA-MT3809G-eng December, 2014 Data Sheet
    DS-VA-MT3809G-eng December, 2014 Data Sheet MT3809G Series Variable Area MT3809G General Purpose Housing Metal Tube Variable Area Flowmeters Overview Brooks MT3809 meter operation is based on the variable area principle. The all metal meter is ideal for a variety of gas, liquid and steam applications. These meters are
    Original PDF
    Always a good solution Overview of process
    Always a good solution Overview of process instrumentation and measurement solutions Contents KROHNE trademarks used in this brochure: KROHNE AST CalSys CARGOMASTER Configure it EcoMATE KROHNE Care OPTIBATCH OPTIFLEX OPTIFLUX OPTIMASS OPTISONIC OPTISOUND OPTISWIRL
    Original PDF
    Always a good solution Overview of process
    Always a good solution Overview of process instrumentation and measurement solutions Contents KROHNE trademarks used in this brochure: KROHNE AST CalSys CARGOMASTER Configure it EcoMATE KROHNE Care OPTIBATCH OPTIFLEX OPTIFLUX OPTIMASS OPTISONIC OPTISOUND OPTISWIRL
    Original PDF
    Multipin Design Thermocouple Connectors Model MTC
    Multipin Design Thermocouple Connectors Model MTC with 200°C (392°F) Maximum Service Temperature From $ 41 For Five-Cavity Female Flanged Connector– Pins Sold Separately ߜ Thermocouple Alloy Pins ߜ Air and Moisture Resistant Connection ߜ R e m o v a b l e Crimp
    Original PDF
    lf654
    LF654 /LF620 LF654 /LF622 1/2" to 18" (15 to 450 mm) Field Intelligent Device – Mount Anywhere Series - Flanged Electromagnetic Flowmeter Introduction The electromagnetic flowmeter uses Faraday’s Law of electromagnetic induction to measure the process flow.
    Original PDF
    Notice of Intellectual Property Rights The OMEGA®
    Notice of Intellectual Property Rights The OMEGA® Handbook Series is based upon original intellectual property rights that were created and developed by OMEGA. These rights are protected under applicable copyright, trade dress, patent and trademark laws. The distinctive, composite appearance of these Handbooks is uniquely identified with
    Original PDF
    ANSI color code shown To order IEC color code see
    ANSI color code shown To order IEC color code see pg. H-9 Duplex Insulated Copper-Constantan Duplex ANSI Type T New! “SLE” Special Limits of Error Available ALL MODELS AVAILABLE FOR FAST DELIVERY! ANSI Color Code: Positive Wire, Blue; Negative Wire, Red; Overall, Brown
    Original PDF
    Solid State Relays High Reliability, Vdc
    Solid State Relays High Reliability, Vdc Input/Vac Output, Vac Input/Vac Output SSRL Series Starts at SSRL240AC10, $25, shown smaller than actual size. 21 $ ߜ Current Ratings to 100 A ߜ Multi-Million Cycle Life ߜ Compatible with Temperature Controllers
    Original PDF