FIVE RELAY STAB Search Results
FIVE RELAY STAB Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DS3680D | Texas Instruments | Quad Telephone Relay Drivers 14-SOIC 0 to 70 |
|
|
|
| ULN2003LVPWR | Texas Instruments | Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 |
|
|
|
| ULN2003V12PWR | Texas Instruments | Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 |
|
|
|
| ULN2003LVDR | Texas Instruments | Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 |
|
|
|
| DS3680DE4 | Texas Instruments | Quad Telephone Relay Drivers 14-SOIC 0 to 70 |
|
|
Documents mentioning FIVE RELAY STAB
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Maxim > App Notes > Analog switches and | Maxim > App Notes > Analog switches and multiplexers Automatic test equipment (ATE) Miscellaneous circuits Keywords: single-coil latching relay, relay memory, half bridge, full Aug 09, 2010 APPLICATION NOTE 4486 Single-coil latching relay drivers Abstract: The schematics of Figure 1 illustrate five relay-driving circuits, depending on the input-signal logic levels, their coding, |
Original | ||||
| Benefits of the new Five colours for an easier | Benefits of the new Five colours for an easier identification of coil voltage AC red: 230 Vac (North America 120 Vac) dark red: others Vac system Push-to-Test-Pull-to-Lock button (PTPL) grey: Vac/dc DC C dark blue: others Vdc Coil voltage marked on the top face of the relay |
Original | ||||
| radss | "S55T ASEA ssr Omehmim (mm language) f 1 I W I i I 1 RF 6 3 7 - 1 4 5 i(EngMl) RADSS with Impedance Relay on samt CT core ■rr^ w rH w production by Daaipi c M a d by Orewmg ctnctad by - Df»M) by T. Forford I W " k /mdtcM M Rgtn i** Ref. 704.978 Hungarin Station Sajoszoged 220 kV, 2Z,12L |
OCR Scan | ||||
| General-purpose Relay G2RS New Model Slim and | General-purpose Relay G2RS New Model Slim and Space-saving Power Plug-in Relay • Lockable test button models now available. • Built-in mechanical operation indicator. • Provided with nameplate. • AC type is equipped with a coil-disconnection self-diagnostic |
Original | ||||
| General-purpose Relay G2RS New Model Slim and | General-purpose Relay G2RS New Model Slim and Space-saving Power Plug-in Relay • Lockable test button models now available. • Built-in mechanical operation indicator. • Provided with nameplate. • AC type is equipped with a coil-disconnection self-diagnostic |
Original | ||||
| radha | Types SPAE, RADHA andSU91a 1MDB09017-EN P age 1 High impedance differential relays ABB Network Control & Protection ■ SU91a SPAE (235199) (M N D 70.990) RADHA (7 8 2 7 9 4 ) Features •Secure operation, not affected by CT satura tion •Voltage limiting resistors |
OCR Scan | ||||
| General-purpose Relay G2RS Slim and Space-saving | General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay • Lockable test button models now available. • Built-in mechanical operation indicator. • Provided with nameplate. • AC type is equipped with a coil-disconnection self-diagnostic |
Original | ||||
| General-purpose Relay G2RS-(S) Slim and | General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay • Lockable test button models now available. • Built-in mechanical operation indicator. • Provided with nameplate. • AC type is equipped with a coil-disconnection selfdiagnostic function (LED type). |
Original | ||||
| Fluorescent High Bay Occupancy Sensor | Fluorescent High Bay Occupancy Sensor Installation Instructions Hubbell Building Automation 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215 www.hubbell-automation.com PRODUCT CONFIGURATIONS |
Original | ||||
| radsb | Transformer differential protection RADSB 1MRK 504 002-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970883) Features • Three phase differential protection with two, three, five or six through-current restraint inputs |
Original | ||||
| A l i » n i » *ÊtABrra™ eovEfii CA N CELLA A B B | A l i » n i » *ÊtABrra™ eovEfii CA N CELLA A B B Relays IN FORM ATIO N Frollitele R F R , June 1981 Edition 2 InfQ.Wo, R K 625-3QQ £ Page RaS7454 I Transform er differential relay type RAD SR The transformer relay type R A D SB is a three-phase differential |
OCR Scan | ||||
| rxkb 1 | ASEA Catalogue RK 31-14 E Edition 1 July 1975 Time-lag relay type RXKB 1 File R, Part 1 c Tô Imïb TTI lF|L|E|Xr- Resetting and recovery time approx. 20 ms. Dispersion of operating time ± 0.5 % of highest scale value. For d.c. supply. With separate rectifying |
OCR Scan | ||||
| csa22 | PCB Power Relay – G2R Power Relays A Power Relay for a Variety of Purposes with Various Models ■ Conforms to EN 61810-1, UL508, CSA22.2, SEV, SEMKO. ■ Meets VDE0700 requirements for household products according to VDE0110. ■ Clearance and creepage distance: |
Original | ||||
| radsb | Type RADSB A8EA 8R O W N BOVEFtf Transformer differential protection 1MDB04007-EN Page 1 March 1992 Changed since August 1990 Data subject to change wihtout notice ABB N etw ork Control & Protection (840536) I (90142) Features Application •Complete phase and earth fault protection |
OCR Scan | ||||
|
|
||||||
| 5/10/07 15:39 Page 188 Text Signal Relay – G6E | 5/10/07 15:39 Page 188 Text Signal Relay – G6E PCB Text Signal Relay – G5V-1 PCB Engineering Data Sub-miniature, Sensitive SPDT Signal Switching Relay 5,000 3,000 1,000 700 500 300 100 70 50 24-VDC resistive load ■ High sensitivity: 98mW pickup coil power. |
Original | ||||
| MEDER electronic RELAY APPLICATIONS Reed Relay | MEDER electronic RELAY APPLICATIONS Reed Relay Applications Introduction Reed Relay Features Reed Relay applications continue grow every year despite severe competition from other small switching devices such as semiconductors and electromechanical armature style relays. |
Original | ||||
| General-purpose Relay G2R-@-S | General-purpose Relay G2R-@-S CSM_G2R-_-S_DS_E_2_1 Slim and Space-saving Power Plug-in Relay ■ Lockable test button models now available. ■ Built-in mechanical operation indicator. ■ Provided with nameplate. ■ AC type is equipped with a coil-disconnection self-diagnostic |
Original | ||||
| MEDER electronic RELAY APPLICATIONS Reed Relay | MEDER electronic RELAY APPLICATIONS Reed Relay Applications Introduction Reed Relay Features Reed Relay applications continue grow every year despite severe competition from other small switching devices such as semiconductors and electromechanical armature style relays. |
Original | ||||
| SPAA 120 C and SPAA 121 C Feeder protection relay | SPAA 120 C and SPAA 121 C Feeder protection relay User´s manual and Technical description B I n = 1A 5A ( I ) I n = 1A 5A ( I o ) U n = 100V 110V ( U o ) f n = 50Hz 60Hz 2I > I 2 I 5 L1 I L3 U o I o IRF SPAA 120 C 80…265V – ~ 18…80V – I >/I n U aux |
Original | ||||
| spam 150 | SPAM 150 C Motor protection relay User´s manual and Technical description 3I >> 3 2 (I ) I n = 1A 5A (I o ) I n = 1A 5A f n = 50Hz I 5 L1 I L2 I L3 I I o IRF 60Hz SPAM 150 C 80…265V – ~ 18…80V – NO NC I θ /I n t 6x [ s] p [ %] θ a [ %] θ i [ %] |
Original | ||||
| s7-1200 | 3 © Siemens AG 2013 SIMATIC S7-1200 3/2 Introduction 3/4 3/4 3/8 3/12 3/16 3/20 Central processing units CPU 1211C CPU 1212C CPU 1214C CPU 1215C CPU 1217C 3/23 3/23 3/27 3/31 3/36 SIPLUS central processing units SIPLUS CPU 1211C SIPLUS CPU 1212C SIPLUS CPU 1214C |
Original | ||||
| uw-485 | Technical Data Sheet UW-485 UW485-DTRdoc-01.07 In reference to UW485-1.20 NETRONIX UW-485 1. Table of contents 1. 2. 3. Table of contents… 2 Features… 3 |
Original | ||||
| Power PCB Relay G2R • Creepage distance of 8.0 mm | Power PCB Relay G2R • Creepage distance of 8.0 mm (0.31) min. between coil and contact. • Dual-winding latching type available. • Plug-in and quick-connect terminals available. • High sensitivity (360 mW) and high capacity (16 A) types available. • Highly stable magnetic circuit for latching endurance and |
Original | ||||
| New G2RS Series The G2RS Space-saving Power | New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Nameplate Overview LED indicator Mechanical indicator Test button |