Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FASTON CRIMP HEIGHT Search Results

    FASTON CRIMP HEIGHT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    5159002311193111LF
    Amphenol Communications Solutions Standard Power Receptacle, Type F24/H7, Vertical, Solder-to-Wire/Faston, 31 Position, 5.08mm (0.2inch) Centerline PDF
    51590291519620LF
    Amphenol Communications Solutions Standard Power Receptacle, Type H, Vertical, Faston, 15 Position, 10.16mm (0.4 in) Centerline PDF
    5159002311194111LF
    Amphenol Communications Solutions Standard Power Receptacle, Type F24/H7, Vertical, Solder-to-Wire/Faston, 31 Position, 5.08mm (0.2inch) Centerline PDF
    10104321-009RLF
    Amphenol Communications Solutions Universal Contact, 3.50mm Height PDF
    10094594-009RLF
    Amphenol Communications Solutions Universal Contact, 1.30mm Height PDF

    Documents mentioning FASTON CRIMP HEIGHT

    Document Partial File Text Tags Type PDF
    FASTON Terminals (Insulated and Uninsulated) Page
    FASTON Terminals (Insulated and Uninsulated) Page Head_12 Ultra-Fast FullyHel. Insulated Con. Bold FASTON (Continued)_9pt Receptacles Helvetica and Lt Condensed Tabs Product Facts n One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short
    Original PDF
    FASTON Terminals (Insulated and Uninsulated)
    FASTON Terminals (Insulated and Uninsulated) Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts ■ One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
    Original PDF
    FASTON Terminals (Insulated and Uninsulated)
    FASTON Terminals (Insulated and Uninsulated) Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts ■ One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
    Original PDF
    FASTON Terminals (Insulated and Uninsulated)
    FASTON Terminals (Insulated and Uninsulated) Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts ■ One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
    Original PDF
    FASTON Terminals (Insulated and Uninsulated)
    FASTON Terminals (Insulated and Uninsulated) Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts ■ One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
    Original PDF
    FASTON Terminals (Insulated and Uninsulated)
    FASTON Terminals (Insulated and Uninsulated) Ultra-Fast Fully Insulated FASTON Receptacles and Tabs Product Facts ■ One-piece Fully Insulated Premier Line FASTON Receptacle crimp helps prevent shock and short hazards ■ Designed for correct lead-in of tab
    Original PDF
    114-2079
    Application Specification 114-2079 FASTON* Flag Receptacles with F" -Crimp Feature NOTE i 27 OCT 08 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    114-2036
    Application Specification 114-2036 FASTON* Straight Receptacles with F-" Crimp Feature NOTE i 06 AUG 08 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    114-2126
    Application Specification FASTON* F-" Crimp Center-Strip Flag Receptacles NOTE i 114-2126 05 NOV 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification FASTON* 110 Series Flag
    Application Specification FASTON* 110 Series Flag Receptacles with F" Crimp Feature NOTE i 114-2028 02 APR 08 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 mm [+.005 in.] and angles have a tolerance
    Original PDF
    TYCO ELECTRONICS TECHNOLOGY PORTFOLIO Connector
    TYCO ELECTRONICS TECHNOLOGY PORTFOLIO Connector Systems / Electromechanical Components Circuit Protection Devices Magnetics Wireless Components Racks and Panels Antennas, GPS Antennas, Integrated Antenna Systems Touch Screens Resistors and Inductors Printed Circuit Board
    Original PDF
    piggyback
    Application Specification 114-2082 FASTON* Piggyback Receptacles NOTE i 28 MAR 08 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-13076 PIDG* FASTON*
    Application Specification 114-13076 PIDG* FASTON* Tabs and Fully-Insulated Receptacles NOTE 09 JAN 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    114-2032
    Application Specification 114-2032 FASTON* Reversible Flag Receptacles 30 JUL 08 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    AMP-O-LECTRIC Model G Terminating Machine Fast
    AMP-O-LECTRIC Model G Terminating Machine Fast Facts • Quieter • Improved guarding and lighting • Toolless changeover of applicators • Precision manual- or autoadjust for crimp height • Total and batch counter • Accepts all existing TE miniature
    Original PDF
    FASTON Terminals (Insulated and Uninsulated) Page
    FASTON Terminals (Insulated and Uninsulated) Page Head_12 Application Tooling Hel. Con. Bold (Continued)_9pt Helvetica Lt Condensed AMP-O-LECTRIC Model “G” Termination Machines A totally new design of our most popular machine for bench-top operation. It features a quiet and
    Original PDF
    Application Specification 114-2070 AMPLIVAR*
    Application Specification 114-2070 AMPLIVAR* FASTON* Tab Contacts NOTE i 08 DEC 08 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification Ultra- Fast Series 110,
    Application Specification Ultra- Fast Series 110, 125, 187, 205, and 250 Fully- Insulated FASTON* Terminals NOTE i 114-- 2123 02 OCT 09 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
    Original PDF
    applicators
    AMP-O-LECTRIC Model G Terminating Machine Fast Facts • Quieter • Improved guarding and lighting • Toolless changeover of applicators • Precision manual- or autoadjust for crimp height • Total and batch counter • Accepts all existing Tyco Electronics miniature
    Original PDF
    Application Specification Ultra-Pod FASTON*
    Application Specification Ultra-Pod FASTON* 114-2124 Fully Insulated Receptacles and Tabs NOTE i 17 DEC 08 Rev N All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-- 13047 Budget
    Application Specification 114-- 13047 Budget FASTON* Receptacle Contacts 24 NOV 09 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-- 2025 FASTIN-
    Application Specification 114-- 2025 FASTIN- FASTON* Tabs, Receptacles, and Housings NOTE i 13 AUG 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification Pre- Insulated Diamond
    Application Specification Pre- Insulated Diamond Grip (PIDG*) FASTON* Receptacle Contacts NOTE i 114-- 1002 16 NOV 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    FASTON Terminals Insulated and Uninsulated FASTON
    FASTON Terminals Insulated and Uninsulated FASTON Terminals (Insulated and Uninsulated Tyco Electronics Corporation Harrisburg, Pennsylvania www.tycoelectronics.com 82004 Revised 07-2006 5M SK FP RoHS Ready FASTON Terminals (Insulated and Uninsulated) Page Head_12
    Original PDF