Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FAIL SAFE DESIGN Search Results

    FAIL SAFE DESIGN Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SAFEB911MAL0F00
    Murata Manufacturing Co Ltd SAW Filter, 1 Function(s), 911.5MHz, 5 Pin(s) PDF
    SAFEA2G45MA0F0A
    Murata Manufacturing Co Ltd SAW Filter, 1 Function(s) PDF
    SAFEA2G45MB0F0A
    Murata Manufacturing Co Ltd SAW Filter, 1 Function(s), 2442MHz, 5 Pin(s) PDF
    SAFEY634MAA0F0A
    Murata Manufacturing Co Ltd SAW Filter, 1 Function(s) PDF
    SAFEA2G45MC0F0A
    Murata Manufacturing Co Ltd SAW Filter, 1 Function(s) PDF

    FAIL SAFE DESIGN Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    80C52

    Abstract: C504
    Contextual Info: Fail Safe Mechanisms C504 8 Fail Safe Mechanisms The C504 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer WDT , with variable time-out period from 512 µs up to


    Original
    PDF

    mtl4501-sr

    Abstract: MTL5501-SR IEC61508-2 iec61508 relay 29ma IEC61508
    Contextual Info: MTL4501-SR MTL5501-SR MTL4501-SR Hazardous area Safe area FAIL-SAFE SWITCH/PROXIMITYDETECTOR INTERFACE Resistors must always be fitted for switch inputs with LFD 6 5 4 1k4W With the MTLx501-SR, a fail-safe switch/proximity detector located in the hazardous area can control an isolated fail-safe


    Original
    MTL4501-SR MTL5501-SR MTLx501-SR, MTLx501-SR 1232mW 1160mW 1392mW 1200mW mtl4501-sr MTL5501-SR IEC61508-2 iec61508 relay 29ma IEC61508 PDF

    80C52

    Abstract: SAB-C502
    Contextual Info: Fail Safe Mechanisms 8 Fail Safe Mechanisms The SAB-C502 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer WDT , with variable time-out period from 512 µs up to


    Original
    SAB-C502 80C52 PDF

    Schmersal AZM 160

    Abstract: 3XXXM AZM160 aes 3335
    Contextual Info: Fail-Safe Standstill Monitor FWS 1106 DC-Version • 1 Enabling path • Reset-input r • Fail-safe recognition of a machine standstill with one or two inductive proxim ity switches and an additional standstill signal • Fail-safe controlling of solenoid Interlocks


    OCR Scan
    PDF

    SLLA082

    Abstract: SN65LVDT32A SN65LVDS32A
    Contextual Info: Application Report SLLA082 - August 2000 The Active Fail-Safe Feature of the SN65LVDS32A Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components


    Original
    SLLA082 SN65LVDS32A LVDS32A) SN65LVDT32A SN65LVDS32A PDF

    Philips sbc 345 Temperature Control

    Abstract: TJA1054A UJA1061TW BAT14 TJA1055 HTSSOP32 ISO11898-3 J2602 TJA1020 TJA1054
    Contextual Info: UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 03 — 27 June 2006 Preliminary data sheet 1. General description The UJA1061 fail-safe System Basis Chip fail-safe SBC replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller


    Original
    UJA1061 UJA1061 ISO11898-3 TJA1054, TJA1054A TJA1055 Philips sbc 345 Temperature Control UJA1061TW BAT14 TJA1055 HTSSOP32 J2602 TJA1020 TJA1054 PDF

    SLLA082A

    Abstract: WINDOW COMPARATOR LVDS32 SN65LVDS32B SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B
    Contextual Info: Application Report SLLA082A - November 2000 The Active Fail-Safe Feature of the SN65LVDS32B Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components


    Original
    SLLA082A SN65LVDS32B LVDS32B) WINDOW COMPARATOR LVDS32 SN65LVDS32B SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B PDF

    WINDOW COMPARATOR

    Abstract: LVDS32 SN65LVDS32B SN65LVDS33 SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B
    Contextual Info: Application Report SLLA082B - October 2001 Active Fail-Safe in TI’s LVDS Receivers Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Many innovative LVDS fail-safe solutions require either external


    Original
    SLLA082B SN65LVDS32B LVDS32B) WINDOW COMPARATOR LVDS32 SN65LVDS33 SN65LVDS3486B SN65LVDS9637B SN65LVDT32B SN65LVDT3486B SN65LVDT9637B LVDS32B PDF

    MS27661

    Contextual Info: Amphenol Aerospace Series I, LJT Breakaway Fail Safe Lanyard Release Plug How to Order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 1. 2. 3. MS Number Service Class MS27661 T HOW TO ORDER - BY COMMERCIAL PART NUMBER FAIL SAFE 88-5388 OR 91-5388


    Original
    MS27661 MS27661 MIL-DTL-38999, PDF

    Contextual Info: SY54016R Product Brief Low Voltage 1.2V/1.8V CML Differential Line Driver/Receiver with Fail Safe Input 3.2Gbps, 2.5GHz Description The SY54016R is a fully differential, low voltage 1.2V/1.8V CML Line Driver/Receiver with Fail Safe Input. The Fail Safe Input includes a dedicated circuit to sense the


    Original
    SY54016R SY54016R 100mVPK 200mVPP) 100mndia SE-171 M9999-031208 PDF

    Contextual Info: SY54017R Product Brief Low Voltage 1.2V/1.8V CML 2:1 Multiplexer with Fail Safe Input 3.2Gbps, 2.5GHz Description The SY54017R is a fully differential, low voltage 1.2V/1.8V CML 2:1 MUX with Fail Safe Inputs. The Fail Safe Inputs include a dedicated circuit to sense the amplitude of the


    Original
    SY54017R SY54017R 100mVPK 200mVPP) 100mV SE-171 M9999-031208 PDF

    Contextual Info: LJT Breakaway Fail Safe lanyard release plug how to order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 MS27661 T 17 B HOW TO ORDER - BY PROPRIETARY PART NUMBER FAIL SAFE 88-5388 OR 91-5388 35 P A 88 – 5388 MS Number Finish Service Class


    Original
    MS27661 MIL-DTL-38999, PDF

    3XXXM

    Contextual Info: Fail-Safe Delay Timer AZS 2305 AC / DC-Version •3 Enabling paths General information The fail-safe delay tim er AZS 2305 has the following features: • Fail-safe monitoring of a set time value • Adjustable time from 0.1 s to 99 min • Compatible with SCHMERSAL s safety com ponents


    OCR Scan
    89/392/EW 3XXXM PDF

    SO20

    Abstract: U6809B dec-97 202
    Contextual Info: U6809B Fail-Safe IC Description The U6809B is designed to support the fail-safe function of a safety-critical system e.g., ABS. It includes a relay driver, two independent short-circuit-protected lamp drivers which are supplied by redundant ground lines, two


    Original
    U6809B U6809B 250-mA D-74025 03-Dec-97 SO20 dec-97 202 PDF

    Contextual Info: Series III, TV Breakaway Fail Safe Connectors Quick-Disconnect with an Axial Pull of Lanyard Amphenol Aerospace 38999 Amphenol Tri-Start Breakaway Fail Safe Connectors provide unequaled performance in environments requiring instant disengagement. High Speed


    Original
    D38999/20 MIL-DTL-38999/29, MIL-STD-1760 PDF

    Contextual Info: TV Breakaway Fail Safe Connectors quick-disconnect with an axial pull of lanyard Amphenol Tri-Start Breakaway Fail Safe Connectors provide unequalled performance in environments requiring instant disengagement. Designed to provide quick disconnect of a connector plug and receptacle with an axial


    Original
    D38999/20 MIL-DTL-38999 MIL-C-26482, MIL-C-83723) PDF

    RS484

    Abstract: RS-484 AN1076 maxim rs485 reluctance APP1076 MAX3095 MAX3096 vr sensor Steel bar
    Contextual Info: Maxim > App Notes > INTERFACE CIRCUITS Keywords: RS-485, rs484, EIA/TIA-485, fail-safe, variable-reluctance sensor, low-speed, medium speed, ESD protected, rs485 transceiver May 24, 2002 APPLICATION NOTE 1076 Fail-Safe, Low-Speed, Variable-Reluctance Sensors


    Original
    RS-485, rs484, EIA/TIA-485, rs485 RS-485 MAX3096 com/an1076 MAX3095: MAX3096: AN1076, RS484 RS-484 AN1076 maxim rs485 reluctance APP1076 MAX3095 vr sensor Steel bar PDF

    car ecu wiring system service manual

    Abstract: cars ecu UJA106x NXP Logic fmea ISO11898-2 "bat 42" BAT14 PESD1LIN s34 schottky diode tja1040
    Contextual Info: NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.9 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.9 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner


    Original
    UJA106x UJA1061, UJA1065, UJA1066, UJA1069 UJA1062 AH0802 UJA106x car ecu wiring system service manual cars ecu NXP Logic fmea ISO11898-2 "bat 42" BAT14 PESD1LIN s34 schottky diode tja1040 PDF

    Contextual Info: LJT Breakaway Fail Safe quick-disconnect with an axial pull of lanyard Amphenol LJT Breakaway Fail Safe Connectors provide unequalled performance in environments requiring instant disengagement. Designed to provide quick disconnect of a connector plug and receptacle with an axial pull on the lanyard, the


    Original
    MIL-DTL-38999 MIL-C-26482, MIL-C-83723) PDF

    car ecu wiring system service manual

    Abstract: GP010 K-line interface AH0802 can muth ecu repair tja1040 TJA1054 vw connector principal BAT42
    Contextual Info: NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.8 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.8 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner


    Original
    UJA106x UJA1061, UJA1065, UJA1066, UJA1069 UJA1062 AH0802 UJA106x car ecu wiring system service manual GP010 K-line interface can muth ecu repair tja1040 TJA1054 vw connector principal BAT42 PDF

    Contextual Info: Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver Noise Filtering and Fail-Safe Literature Number: SNLS370B Obsolete Device DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL


    Original
    DS78LS120 DS78LS120 SNLS370B PDF

    ds75150

    Contextual Info: Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver Noise Filtering and Fail-Safe Literature Number: SNLS370B September 1999 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL


    Original
    DS78LS120 DS78LS120 SNLS370B ds75150 PDF

    U6808B

    Abstract: t45v
    Contextual Info: U6808B Special Fail-Safe IC Description The U6808B is designed to support the fail-safe function of a safety critical system e.g. ABS. It includes a relay driver, a watchdog controlled by an external R/C-network and a reset circuit initiated by an over- and undervoltage


    Original
    U6808B U6808B 250-mA MIL-STD-883 D-74025 18-Jan-01 t45v PDF

    U6808B

    Abstract: 11-pin relay pin out diagram
    Contextual Info: U6808B Special Fail-Safe IC Description The U6808B is designed to support the fail-safe function of a safety critical system e.g. ABS. It includes a relay driver, a watchdog controlled by an external R/C-network and a reset circuit initiated by an over- and undervoltage


    Original
    U6808B U6808B 250-mA D-74025 03-Dec-97 11-pin relay pin out diagram PDF