FAIL SAFE CH Search Results
FAIL SAFE CH Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCKE905ANA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 2.7 to 23V, 4A, Auto-retry, Fixed Over Voltage Clamp, WSON8 | Datasheet | ||
| TCKE903QNA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 3 to 23V, 4A, Auto-retry, Fixed Over Voltage Clamp, WSON8 | Datasheet | ||
| TCKE905NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 2.7 to 23V, 4A, Latch, Fixed Over Voltage Clamp, WSON8 | Datasheet | ||
| TCKE912NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 2.7 to 23V, 4A, Auto-retry, Fixed Over Voltage Clamp, WSON8 | Datasheet | ||
| TCKE912NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 2.7 to 23V, 4A, Latch, Fixed Over Voltage Clamp, WSON8 | Datasheet |
Documents mentioning FAIL SAFE CH
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| uja1061 | UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 03 — 27 June 2006 Preliminary data sheet 1. General description The UJA1061 fail-safe System Basis Chip (fail-safe SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller |
Original | ||||
| c504 | Fail Safe Mechanisms C504 8 Fail Safe Mechanisms The C504 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer (WDT), with variable time-out period from 512 µs up to |
Original | ||||
| mtl4501-sr | MTL4501-SR – MTL5501-SR MTL4501-SR Hazardous area Safe area FAIL-SAFE SWITCH/PROXIMITYDETECTOR INTERFACE Resistors must always be fitted for switch inputs with LFD 6 5 4 1k4W With the MTLx501-SR, a fail-safe switch/proximity detector located in the hazardous area can control an isolated fail-safe |
Original | ||||
| sab-c502 | Fail Safe Mechanisms 8 Fail Safe Mechanisms The SAB-C502 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer (WDT), with variable time-out period from 512 µs up to |
Original | ||||
| Fail-Safe Standstill Monitor FWS 1106 DC-Version | Fail-Safe Standstill Monitor FWS 1106 DC-Version • 1 Enabling path • Reset-input r • Fail-safe recognition of a machine standstill with one or two inductive proxim ity switches and an additional standstill signal • Fail-safe controlling of solenoid Interlocks |
OCR Scan | ||||
| slla082 | Application Report SLLA082 - August 2000 The Active Fail-Safe Feature of the SN65LVDS32A Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components |
Original | ||||
| ms27661 | Amphenol Aerospace Series I, LJT Breakaway Fail Safe Lanyard Release Plug How to Order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 1. 2. 3. MS Number Service Class MS27661 T HOW TO ORDER - BY COMMERCIAL PART NUMBER FAIL SAFE 88-5388 OR 91-5388 |
Original | ||||
| Fail-Safe Delay Timer AZS 2305 AC / DC-Version ■3 | Fail-Safe Delay Timer AZS 2305 AC / DC-Version ■3 Enabling paths General information The fail-safe delay tim er AZS 2305 has the following features: • Fail-safe monitoring of a set time value • Adjustable time from 0.1 s to 99 min • Compatible with SCHMERSAL s safety com ponents |
OCR Scan | ||||
| uja106x | NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.9 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.9 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner |
Original | ||||
| uja1069 | UJA1069 LIN fail-safe system basis chip Rev. 03 — 10 September 2007 Product data sheet 1. General description The UJA1069 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Local Interconnect |
Original | ||||
| uja1069 | UJA1069 LIN fail-safe system basis chip Rev. 02 — 5 March 2007 Preliminary data sheet 1. General description The UJA1069 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Local Interconnect |
Original | ||||
| uja1069 | UJA1069 LIN fail-safe system basis chip Rev. 04 — 28 October 2009 Product data sheet 1. General description The UJA1069 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Local Interconnect |
Original | ||||
| Obsolete Device DS78LS120 DS78LS120 Dual | Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) Literature Number: SNLS370B September 1999 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL |
Original | ||||
| uja1066 | UJA1066 High-speed CAN fail-safe system basis chip Rev. 03 — 17 March 2010 Product data sheet 1. General description The UJA1066 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller Area Network |
Original | ||||
|
|
||||||
| uja1066 | UJA1066 High-speed CAN fail-safe system basis chip Rev. 02 — 5 May 2009 Product data sheet 1. General description The UJA1066 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller Area Network |
Original | ||||
| multidrop | Maxim > App Notes > HIGH-SPEED INTERCONNECT Keywords: LVDS, LVDS multiple-drop bus, LVDS Mux, Fail-safe, Common Mode biasing, resistor tolerance, LVDS receiver biasing Feb 23, 2007 APPLICATION NOTE 4007 Robust, Fail-Safe Biasing Circuit for AC-Coupled Multidrop LVDS Bus |
Original | ||||
| uja1061 | UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 04 — 27 April 2007 Product data sheet 1. General description The UJA1061 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller Area Network |
Original | ||||
| y^iyixivM 19-1138; Rev 0:9/96 Fail-Safe, | y^iyixivM 19-1138; Rev 0:9/96 Fail-Safe, High-Speed (10Mbps), Slew-Bate-Lim ited RS-485/RS-422 Transceivers .F eatures True Fail-Safe Receiver While Maintaining EIA/TIA-485 Compatibility Enhanced Slew-Rate Limiting Facilitates Error-Free Data Transmission |
OCR Scan | ||||
| uja1061 | UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 06 — 9 March 2010 Product data sheet 1. General description The UJA1061 fail-safe System Basis Chip (SBC) replaces basic discrete components that are common in every Electronic Control Unit (ECU) with a Controller Area Network (CAN) |
Original | ||||
| UJA1065 High-speed CAN/LIN fail-safe system basis | UJA1065 High-speed CAN/LIN fail-safe system basis chip Rev. 06 — 22 November 2007 Product data sheet 1. General description The UJA1065 fail-safe System Basis Chip (SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller Area Network |
Original | ||||
| UJA1065 High-speed CAN/LIN fail-safe system basis | UJA1065 High-speed CAN/LIN fail-safe system basis chip Rev. 07 — 25 February 2010 Product data sheet 1. General description The UJA1065 fail-safe System Basis Chip (SBC) replaces basic discrete components that are common in every Electronic Control Unit (ECU) with a Controller Area Network (CAN) |
Original | ||||