Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FAIL SAFE Search Results

    FAIL SAFE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    ISO7330FCDWR
    Texas Instruments Robust EMC, Low Power, Triple-Channel 3/0 Digital Isolator, Fail-Safe Low 16-SOIC -40 to 125 Visit Texas Instruments Buy
    ISO7420FCCD
    Texas Instruments Low-Power 2/0 Dual Channel Digital Isolator with Fail-Safe Output Low and Noise Filter 8-SOIC -40 to 125 Visit Texas Instruments Buy
    ISO7310CDR
    Texas Instruments Robust EMC, Low Power, Single-Channel 1/0 Digital Isolator, Fail-Safe High 8-SOIC -40 to 125 Visit Texas Instruments Buy
    ISO7141FCCDBQR
    Texas Instruments 4242-VPK Small-Footprint and Low-Power 3/1 Quad Channel Digital Isolator with Fail-Safe Output Low 16-SSOP -40 to 125 Visit Texas Instruments Buy
    ISO7340FCDWR
    Texas Instruments Robust EMC, Low Power, Quad-Channel 4/0 Digital Isolator, Fail-Safe Low 16-SOIC -40 to 125 Visit Texas Instruments Buy
    SF Impression Pixel

    FAIL SAFE Price and Stock

    Select Manufacturer

    Bourns Inc 2035-09-SM-RPLF

    Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 90V Miniature 2 Pole
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2035-09-SM-RPLF Reel 67,500 1,500
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $0.49
    Buy Now

    KEMET Corporation C0805F104K5RAC7800

    Multilayer Ceramic Capacitors MLCC - SMD/SMT 50V 0.1uF X7R 0805 10%
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI C0805F104K5RAC7800 Reel 50,000 2,500
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $0.06
    Buy Now

    Littelfuse Inc SG75

    Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 52-98V 2A GDT T/R 2 Term
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI SG75 Reel 22,000 2,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $0.64
    Buy Now

    Bourns Inc 2036-15-SM-RPLF

    Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 150VDC 3-POLE 500V@1KV/US
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 2036-15-SM-RPLF Reel 14,000 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 $1.05
    • 10000 $0.99
    Buy Now

    TDK Corporation B88069X4301S102

    Gas Discharge Tubes - GDTs / Gas Plasma Arrestors EF1500X
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI B88069X4301S102 Ammo Pack 10,400 100
    • 1 -
    • 10 -
    • 100 $1.25
    • 1000 $1.02
    • 10000 $0.95
    Buy Now

    Documents mentioning FAIL SAFE

    Document Partial File Text Tags Type PDF
    c504
    Fail Safe Mechanisms C504 8 Fail Safe Mechanisms The C504 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer (WDT), with variable time-out period from 512 µs up to
    Original PDF
    sab-c502
    Fail Safe Mechanisms 8 Fail Safe Mechanisms The SAB-C502 offers enhanced fail safe mechanisms, which allow an automatic recovery from software upset or hardware failure : – a programmable watchdog timer (WDT), with variable time-out period from 512 µs up to
    Original PDF
    Fail-Safe Standstill Monitor FWS 1106 DC-Version
    Fail-Safe Standstill Monitor FWS 1106 DC-Version • 1 Enabling path • Reset-input r • Fail-safe recognition of a machine standstill with one or two inductive proxim ity switches and an additional standstill signal • Fail-safe controlling of solenoid Interlocks
    OCR Scan PDF
    slla082
    Application Report SLLA082 - August 2000 The Active Fail-Safe Feature of the SN65LVDS32A Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components
    Original PDF
    uja1061
    UJA1061 Fault-tolerant CAN/LIN fail-safe system basis chip Rev. 03 — 27 June 2006 Preliminary data sheet 1. General description The UJA1061 fail-safe System Basis Chip (fail-safe SBC) replaces basic discrete components which are common in every Electronic Control Unit (ECU) with a Controller
    Original PDF
    slla082a
    Application Report SLLA082A - November 2000 The Active Fail-Safe Feature of the SN65LVDS32B Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Current LVDS fail-safe solutions require either external components
    Original PDF
    ms27661
    Amphenol Aerospace Series I, LJT Breakaway Fail Safe Lanyard Release Plug How to Order, cont. HOW TO ORDER - BY MILITARY PART NUMBER FAIL SAFE MS27661 1. 2. 3. MS Number Service Class MS27661 T HOW TO ORDER - BY COMMERCIAL PART NUMBER FAIL SAFE 88-5388 OR 91-5388
    Original PDF
    Application Report SLLA082B - October 2001 Active
    Application Report SLLA082B - October 2001 Active Fail-Safe in TI’s LVDS Receivers Mark Morgan and Bryan Smith Advanced Analog Products ABSTRACT Differential line receivers commonly have fail-safe circuits to prevent the receiver from switching on input noise. Many innovative LVDS fail-safe solutions require either external
    Original PDF
    mtl4501-sr
    MTL4501-SR – MTL5501-SR MTL4501-SR Hazardous area Safe area FAIL-SAFE SWITCH/PROXIMITYDETECTOR INTERFACE Resistors must always be fitted for switch inputs with LFD 6 5 4 1k4W With the MTLx501-SR, a fail-safe switch/proximity detector located in the hazardous area can control an isolated fail-safe
    Original PDF
    tis 150-148
    INDUSTRIAL POWER SUPPLIES TIS-SERIES WITH POWER FAIL FUNCTION (OPTION SIG) INDUSTRIELLE STROMVERSORGUNG TIS-SERIE MIT POWER FAIL FUNKTION (OPTION SIG) ALIMENTATIONS INDUSTRIELLES SERIE TIS AVEC FONCTION POWER FAIL (OPTION SIG) ♦ TIS 150-124 SIG ♦ TIS 150-148 SIG
    Original PDF
    Fail-Safe Delay Timer AZS 2305 AC / DC-Version ■3
    Fail-Safe Delay Timer AZS 2305 AC / DC-Version ■3 Enabling paths General information The fail-safe delay tim er AZS 2305 has the following features: • Fail-safe monitoring of a set time value • Adjustable time from 0.1 s to 99 min • Compatible with SCHMERSAL s safety com ponents
    OCR Scan PDF
    c509-l
    Fail Save Mechanisms C509-L 8 Fail Save Mechanisms The C509-L offers two on-chip peripherals which monitor the program flow and ensure an automatic "fail-safe" reaction for cases where the controller’s hardware fails or the software hangs up: – A programmable watchdog timer (WDT) with variable time-out period from 189 microseconds
    Original PDF
    Maxim > App Notes > POWER-SUPPLY CIRCUITS
    Maxim > App Notes > POWER-SUPPLY CIRCUITS Keywords: voltage hysteresis, power monitoring, power fail circuitry, power fail, CPU supervisor, CPU super, reset Jun 03, 2003 APPLICATION NOTE 245 Adding Hysteresis to CPU Supervisor Voltage Sense Inputs Monitoring Upstream Voltage Supplies for Power-Fail Warnings
    Original PDF
    tps3306
    TPS3306-15, TPS3306-18, TPS3306-20, TPS3306-25, TPS3306-33 DUAL PROCESSOR SUPERVISORY CIRCUITS WITH POWER-FAIL SLVS290 – APRIL 2000 D D D D D D D D D D D Dual Supervisory Circuits With Power-Fail for DSP and Processor-Based Systems Voltage Monitor for Power-Fail or
    Original PDF
    rs484
    Maxim > App Notes > INTERFACE CIRCUITS Keywords: RS-485, rs484, EIA/TIA-485, fail-safe, variable-reluctance sensor, low-speed, medium speed, ESD protected, rs485 transceiver May 24, 2002 APPLICATION NOTE 1076 Fail-Safe, Low-Speed, Variable-Reluctance Sensors
    Original PDF
    Obsolete Device DS78LS120 DS78LS120 Dual
    Obsolete Device DS78LS120 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) Literature Number: SNLS370B September 1999 DS78LS120 Dual Differential Line Receiver (Noise Filtering and Fail-Safe) General Description The DS78LS120 is a high performance, dual differential, TTL
    Original PDF
    uja106x
    NXP Semiconductors Automotive Innovation Center, Germany APPLICATION HINTS Version 2.9 Fail-safe System Basis Chips UJA106x Application Hints Fail-Safe CAN / LIN System Basis Chips UJA1061, UJA1065, UJA1066, UJA1069 Version 2.9 Authors: Thorsten Kauder, Matthias Muth, Martin Wagner
    Original PDF