EPCOS SPARK GAP Search Results
EPCOS SPARK GAP Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| GBA010LF | Amphenol Communications Solutions | battery holder connector gap type | |||
| TLV71210DBVR | Texas Instruments | 300-mA, Sub-Band-Gap Output Voltage, Low-Iq, Low-Dropout Regulator 5-SOT-23 -40 to 125 |
|
|
|
| TLV71211DBVR | Texas Instruments | 300-mA, Sub-Band-Gap Output Voltage, Low-Iq, Low-Dropout Regulator 5-SOT-23 -40 to 125 |
|
|
|
| TLV71211DBVT | Texas Instruments | 300-mA, Sub-Band-Gap Output Voltage, Low-Iq, Low-Dropout Regulator 5-SOT-23 -40 to 125 |
|
|
|
| TLV71209DBVR | Texas Instruments | 300-mA, Sub-Band-Gap Output Voltage, Low-Iq, Low-Dropout Regulator 5-SOT-23 -40 to 125 |
|
|
Documents mentioning EPCOS SPARK GAP
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| EPCOS Product Profile 2015 Surge Arresters and | EPCOS Product Profile 2015 Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken www.epcos.com Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken Contents Inhalt Important notes Wichtige Hinweise |
Original | ||||
| ssg08x | Switching Spark Gaps Series/Type: SSG08X-1G The following products presented in this data sheet are being withdrawn. Ordering Code B88069X0280T502 Substitute Product Date of Withdrawal 2003-10-02 Deadline Last Orders 2003-11-01 Last Shipments 2003-12-01 For further information please contact your nearest EPCOS sales office, which will also support |
Original | ||||
| switching spark gap | Switching Spark Gaps Series/Type: SSG1X-1 The following products presented in this data sheet are being withdrawn. Ordering Code B88069X0250S102 Substitute Product Date of Withdrawal 2003-10-02 Deadline Last Orders 2003-11-01 Last Shipments 2003-12-01 For further information please contact your nearest EPCOS sales office, which will also support |
Original | ||||
| b88069x0250s102 | Switching Spark Gaps Series/Type: SSG1X-1 The following products presented in this data sheet are being withdrawn. Ordering Code B88069X0250S102 Substitute Product Date of Withdrawal 2003-10-02 Deadline Last Orders 2003-11-01 Last Shipments 2003-12-01 For further information please contact your nearest EPCOS sales office, which will also support |
Original | ||||
| igniter | Switching Spark Gaps Schaltfunkenstrecken Basic circuit pulse igniter Prinzipschaltkreis Impulszündgerät R C General Switching spark gap Schaltfunkenstrecke Load Last RAB0223-W Fig. / Bild 1 General technical information It is increasingly common practice to |
Original | ||||
| switching spark gap | Switching spark gap SSG for SMD handling Series/Type: Ordering code: CAS02XSMD B88069X6321T602 Version/Date: Version: Issue 02 / 2006-10-30 04 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the |
Original | ||||
| cas02x-068 | Switching spark gap SSG with lead wires Series/Type: Ordering code: CAS02X-068 B88069X0680T502 Version/Date: Issue 05 / 2007-11-22 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer |
Original | ||||
| Arresters Surge Arresters Switching Spark Gaps | Arresters Surge Arresters Switching Spark Gaps Überspannungsableiter Surge Arresters 2-Elektroden-Ableiter 2-electrode surge arresters Nennansprechgleichspannung DC spark-over voltage V Light duty EM M5 EC Medium duty N8 A7 L7 4500 Heavy duty A8 A83 2,5/2,5 |
Original | ||||
| arresters | Überspannungsableiter und Schaltfunkenstrecken Surge Arresters and Switching Spark Gaps Produktschrift 2000 / Product Profile 2000 http://www.epcos.com Vorwort Preview Kommunikationseinrichtungen und Systeme zur Datenübertragung können durch Überspannungen und die |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-087 Ordering code: B88069X0870T502 DC spark-over voltage 1) 2) 180… 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02XG Ordering code: B88069X0680T502 DC spark-over voltage 1) 2) 200… 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-070 Ordering code: B88069X0700T502 DC spark-over voltage 1) 2) 200… 250 V ≤ 300 ms 1 000 000 Ignitions 350 15 150 2 60 V kΩ nF µH A Insulation resistance at 100 Vdc > 0.1 GΩ Capacitance at 1 MHz <2 pF Weight ~ 1.5 g Operation and storage temperature |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-067 Ordering code: B88069X0670T502 DC spark-over voltage 1) 2) 200… 250 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-047 Ordering code: B88069X0470T502 DC spark-over voltage 1) 2) 215… 240 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
|
|
||||||
| spark gap | Switching Spark Gap CAS02X-068 Ordering code: B88069X0680T502 DC spark-over voltage 1) 2) 200… 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-069 Ordering code: B88069X0690T502 DC spark-over voltage 1) 2) 205… 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAM02X Ordering code: B88069X5410T502 DC spark-over voltage 1) 2) 230 ± 15 V % Initial values Ignition time tI after 24 hours in darkness 3) 95 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time Switching operations at +25; 125 °C |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-093 Ordering code: B88069X0930T502 DC spark-over voltage 1) 2) 180… 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-091 Ordering code: B88069X0910T502 DC spark-over voltage 1) 2) 190… 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-4731 Ordering code: B88069X4731T502 DC spark-over voltage 1) 2) 190… 240 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-429 Ordering code: B88069X4290T502 DC spark-over voltage 1) 2) 235… 260 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-071 Ordering code: B88069X0710T502 DC spark-over voltage 1) 2) 215… 255 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage |
Original | ||||
| spark gap | Switching Spark Gap CAS02X-119 Ordering code: B88069X1190T502 DC spark-over voltage 1) 2) 190… 255 V 9 000 000 Ignitions 230 1 1 40 ~ 150 Vac kΩ µF µH A Insulation resistance at 100 Vdc > 0.1 GΩ Capacitance at 1 MHz <2 pF Weight ~ 1.5 g Operation and storage temperature |
Original | ||||
| ssg2x-1 | Switching Spark Gap SSG2X-1 Ordering code: B88069X0210S102 Nominal breakdown voltage VN 2000 V Initial values 2) Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV ≤ 2600 1600… 2400 |
Original | ||||
| spark gap | Switching Spark Gap CAS02XC Ordering code: B88069X4040B502 DC spark-over voltage 1) 2) 190… 255 V 9 000 000 Ignitions 230 1 1 40 ~ 150 Vac kΩ µF µH A Insulation resistance at 100 Vdc > 0.1 GΩ Capacitance at 1 MHz <2 pF Weight ~ 1.5 g Operation and storage temperature |
Original | ||||