ENERGIZER LR6 Search Results
Documents mentioning ENERGIZER LR6
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| energizer | PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com ENERGIZER X91 Specifications Classification: Chemical System: Alkaline Zinc-Manganese Dioxide (Zn/MnO 2) No added mercury or cadmium ANSI-15A, IEC-LR6 1.5 volts |
Original | ||||
| energizer | PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com ENERGIZER E96 AAAA Specifications Classification: Chemical System: Industry Standard Dimensions mm (inches) 8.3 (0.327) 7.7 (0.303) 3.8 (0.150) Maximum |
Original | ||||
| en91 | PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com ENERGIZER EN91 Specifications NOT INTENDED FOR RETAIL TRADE Alkaline Zinc-Manganese Dioxide (Zn/MnO 2) No added mercury or cadmium ANSI-15A, IEC-LR6 1.5 volts |
Original | ||||
| energizer | PRODUCT DATASHEET Asia /Pacific 1-800-383-7323 USA Region 1-800-383-7323 /+852-31026623 CANADA ENERGIZER E96 AAAA Specifications Classification: Chemical System: Designation: Nominal Voltage: Nominal IR: Operating Temp: Typical Weight: Typical Volume: Jacket: |
Original | ||||
| ansi-15a | PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com ENERGIZER EN91 AA Specifications NOT INTENDED FOR RETAIL TRADE Alkaline Zinc-Manganese Dioxide (Zn/MnO 2) No added mercury or cadmium ANSI-15A, IEC-LR6 |
Original | ||||
| PRODUCT DATASHEET Asia /Pacific 1-800-383-7323 | PRODUCT DATASHEET Asia /Pacific 1-800-383-7323 USA Region 1-800-383-7323 /+852-31026623 CANADA ENERGIZER E96 Classification: Chemical System: Designation: Nominal Voltage: Nominal IR: Operating Temp: Typical Weight: Typical Volume: Jacket: Shelf Life: Terminal: |
Original | ||||
| PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / | PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com ENERGIZER E96 Specifications Classification: Chemical System: Industry Standard Dimensions mm (inches) 8.3 (0.327) 7.7 (0.303) 3.8 (0.150) Maximum AAAA |
Original | ||||
| M60 Section 1 FRev2 11/25/11 1:36 PM Page 24 | M60 Section 1 FRev2 11/25/11 1:36 PM Page 24 RUGGED & LIGHTWEIGHT ALUMINUM BATTERY HOLDERS Lightweight yet strong, constructed of aircraft grade aluminum. Batteries snap-fit securely into clips. Contacts: Brass, Nickel Plate Lugs: Brass, Tin Plate Frame and Battery Clips: Aluminum |
Original | ||||
| M60 Section 1 FRev2 11/25/11 1:36 PM Page 26 | M60 Section 1 FRev2 11/25/11 1:36 PM Page 26 RUGGED STEEL BATTERY HOLDERS An established design that has gained wide acceptance for commercial and military applications. Batteries are held under constant spring tension assuring low contact resistance. Retainer clips are available to lock batteries in place |
Original | ||||
| M60 Section 1 FRev2 11/25/11 1:35 PM Page 23 | M60 Section 1 FRev2 11/25/11 1:35 PM Page 23 ALUMINUM HOLDERS CONNECTED IN SERIES ELIMINATES WIRING · LABOR SAVING Features pre-connected jumper strap insulated from the Aluminum base. Batteries held in series circuit without need of additional wiring. BATTERY CROSS REFERENCE |
Original | ||||
| capteur pt100 | BattTemp, Thermomètre Pt100 Thermomètre alimenté par batterie Affichage frontal programmable Entrée pour capteur Pt100 Gamme de mesure -200…850°C Température ambiante -10…70°C Précision 0,3°C Durée de vie de la batterie approx. 3 ans IP65 - Humidité relative 98% |
Original | ||||
| Series LR 25-40Amp • 120/240/480 Vac - AC OUTPUT | Series LR 25-40Amp • 120/240/480 Vac - AC OUTPUT • DC or AC Control • Zero Cross and Random Switching • Up to 1200V Transient Capability • SCR Output • PCB Mount Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. |
Original | ||||
| CombiTemp TFR5 TM Room or outdoor temperature | CombiTemp TFR5 TM Room or outdoor temperature sensor Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores |
Original | ||||
| an1337 | AN1337 Optimizing Battery Life in DC Boost Converters Using MCP1640 Author: Valentin C. Constantin, Microchip Technology Inc. INTRODUCTION Microchip Technology Inc. has developed the MCP1640/B/C/D devices for battery-powered applications. These devices possess all the modern |
Original | ||||
|
|
||||||
| CombiTemp TFRN TM Industrial – RTD temperature | CombiTemp TFRN TM Industrial – RTD temperature sensor Main features Pt100 sensor element, ATEX Programmable by touch screen Easy and full programmable 2- or 4-wire HART®, PA Built in graphical display, CombiViewTM DFON optional |
Original | ||||
| pt100 | CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features Pt100 sensor element, 2- or 4-wire Built in graphical display, CombiViewTM DFON optional Head mounted 4…20 mA transmitter, FlexTop type 22xx HART®, PA ATEX |
Original | ||||
| CombiTemp TFRN TM Industrie – RTD | CombiTemp TFRN TM Industrie – RTD Temperatursensor Haupteigenschaften Sensor in Pt100-Ausführung, ATEX Programmierbar über 2- oder 4-polig HART®, PA Eingebautes Grafikdisplay, CombiViewTM DFON optional erhältlich Messkopf Verstärker mit |
Original | ||||