| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| aee16-3662 | RoHS AEE16-3662 EE16 Transformer EE16 Core Design 10 Pin Through Hole Electrical Specifications @ 25°C INDUCTANCE @1KHZ/1V (HP-4284A) 2 - 1: 0.991mH ±10% LEAKAGE INDUCTANCE @100KHZ/1V (HP-4284A) 2 - 1: 150uH MAX (SHORT 6-5) DCR CH-502A (MAX) HI-POT TEST |
Original | ||||
| aee16-3668 | RoHS AEE16-3668 EE16 Transformer EE16 Core Design 6 Pin Through Hole Electrical Specifications @ 25°C INDUCTANCE @1KHZ/1V (HP-4284A) 2 - 1: 0.991mH ±10% LEAKAGE INDUCTANCE @100KHZ/1V (HP-4284A) 2 - 1: 150uH MAX (SHORT 6-5) DCR CH-502A (MAX) 2 - 1: 8.50 OHM |
Original | ||||
| ccfl driving inverter transformer | CCFL Driving Inverter Transformer INT007T TYPE(EPC17) Mechanical Dimension:Unit:mm Characteristic(reference) PART NO. INT007T-1 INPUTVOLTAGE (Vdc) SUITABLE FREQUECY MAX.LAMP WATTE (KHZ) (W) 16.0 30-80 8.0 MAX.OPEN VOLTAGE EFFICIENCY (Vrms) (%) 2000 80 INT008T TYPE(EE16) |
Original | ||||
| High Frequency Wire Wound Transformers EE16 | High Frequency Wire Wound Transformers EE16 Platforms - THT Type AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Topology: Flyback Custom Design Available 1 Electrical Specifications @ 25°C - Operating Temperature -40°C to +130°C |
Original | ||||
| ee16 | High Frequency Wire Wound Transformers EE16 Platforms - THT Type AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Topology: Flyback Custom Design Available 1 Electrical Specifications @ 25°C - Operating Temperature -40°C to +130°C |
Original | ||||
| flyback transformers | FLYBACK TRANSFORMERS EE16 1 to 10 W • Ambient Temperature ≤ 50°C • Primary Reflected Voltage = 90 to 120V • Dielectric Strength ≥ 3750Vac • Creepage Distances ≥ 6mm • Construction conforms to CEI950, CEI335, CEI61558 for reinforced insulation |
Original | ||||
| aee16 | RoHS AEE16 High Frequency Transformers EE16 Core Design Through Hole Vertical Mount for Smaller Foot Print Flyback Topology 3KVrms Hi-pot Rating 18mm Max Ht Operating Temperature -40ºC ~ +130ºC Schematics AEE16-1931 AEE16-2115 AEE16-2517 AEE16-2531 AEE16-2621 |
Original | ||||
| ee16 | High Frequency Wire Wound Transformers EE16 Platforms - THT Type AC/DC and DC/DC Switching Transformers Electronics Reinforced Insulation 3000Vrms Hi-pot Topology: Flyback Custom Design Available Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C 1 |
Original | ||||
| ee16 | TINYSWITCH TRANSFORMERS EE16 1.5 to 5 W • Ambient Temperature ≤ 50°C • Primary Reflected Voltage = 90 to 120V • Dielectric Strength ≥ 3750Vac • Creepage Distances ≥ 6mm • Construction conforms to CEI950, CEI335, CEI61558 for reinforced insulation |
Original | ||||
| transformer | Rapid Transformer Sample Service EE16(H), 8 pin Bobbin Mechanical Drawing 18.7 max 15.5 max 21.4 max 4.7 max 1 2 3 4 4 5 0.75 sq PCB Layout 7 6 5 3 4 15 8 1 2 7.5 3.75 TOP VIEW UNIT:mm |
Original | ||||
| High Frequency Wire Wound Transformers EE16 | High Frequency Wire Wound Transformers EE16 Platforms - THT Vertical AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Power Range: Up to 60W Height: 18.0mm Max Footprint: 18.2mm x 16.0mm Max Topology: Flyback Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C |
Original | ||||
| HIGH FREQUENCY WIRE WOUND TRANSFORMERS EE16 | HIGH FREQUENCY WIRE WOUND TRANSFORMERS EE16 Platforms - THT Vertical AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Power Range: Up to 60W Height: 18.0mm Max Footprint: 18.2mm x 16.0mm Max Topology: Flyback Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C |
Original | ||||
| ee16 | High Frequency Wire Wound Transformers EE16 Platforms - THT Vertical Electronics AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Power Range: Up to 60W Height: 18.0mm Max Footprint: 18.2mm x 16.0mm Max Topology: Flyback Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C |
Original | ||||
| transformer ee-16 | 承 认 书 客户名称: Cypress Semi Conductor 产品型号: Transformer EE-16 (5+5) (rev-A) 日 期: . 2008-11-22 ※如蒙承认,请予承认后签回一份,谢谢!※ 客户确认 批 准 深圳市高威实业有限公司 SHENZHEN GOLDENWAY INDUSTRY CO., LTD |
Original | ||||
|
|
||||||
| Innovative Green Power Solutions AC/DC | Innovative Green Power Solutions AC/DC Charger/Adapter Reference Designs ACT41X Rev 1.4 JUL 2013 -1- www.active-semi.com High Performance AC/DC Switching Power Solutions Application Change Note Revision History 2013 - Jul - 22 Rev 1.4 Page 4.5 Update ACT410 5V2.1A application solution transformer and parameter. |
Original | ||||
| Innovative Green Power Solutions AC/DC | Innovative Green Power Solutions AC/DC Charger/Adapter Reference Designs ACT41X Rev 1.5 Jan 2014 -1- www.active-semi.com High Performance AC/DC Switching Power Solutions Application Change Note Revision History 2014 - Jan - 23 Rev 1.5 Page 4.5 Update ACT410 5V2.1A application solution transformer and parameter. |
Original | ||||
| ap3706 | 5V890mA Charger Solution Using AP3706 System Engineering 2008.05.27 Contents Specifications Demo Board Schematic Bill of Material Transformer Specs Test Results Summary Specification Description Min Typ Max Units 90 47 50/60 264 63 300 VAC |
Original | ||||
| di-77 | Design Idea DI-77 ® TinySwitch-II 3 W Adapter: <200 mW No-Load Consumption Application Device Power Output Input Voltage Output Voltage Topology Adapter TNY263P 3W 85-265 VAC 9 V / 330 mA Flyback Design Highlights • (a similarly rated linear transformer adapter will typically |
Original | ||||
| di-34 | DI-34 Design Idea TinySwitch-II ® 5 W Universal Adapter Application Device Power Output Input Voltage Output Voltage Topology Adapter TNY266PN 5W 85 – 265 VAC 5V Flyback Design Highlights • Simple design: low parts count (23) • <300 mW no-load without transformer bias winding |
Original | ||||
| di-34 | ® Design Idea DI-34 ® TinySwitch-II 5 W Universal Adapter Application Device Power Output Input Voltage Output Voltage Topology Adapter TNY266P 5W 85-265 VAC 5V Flyback Design Highlights The TinySwitch-II frequency jitter feature and transformer construction allow use of a simple filter (L1, L2, C1 and C2) |
Original | ||||
| epr-00015 | Title Engineering Prototype Report (EPR-00015) 3W, Universal Input, Single Output, Isolated Converter with TNY254 (EP-15) Recipients Application Battery Charger Author S. L. Date 11-November -2000 Abstract This document presents the specification, schematic & BOM, transformer calculation, test data, wave forms |
Original | ||||