E2V TECHNOLOGIES SAFETY Search Results
E2V TECHNOLOGIES SAFETY Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CS-SATDRIVEX2-002 | Amphenol Cables on Demand | Amphenol CS-SATDRIVEX2-002 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 2m | |||
| CS-SATDRIVEX2-000.5 | Amphenol Cables on Demand | Amphenol CS-SATDRIVEX2-000.5 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 0.5m | |||
| CS-SATDRIVEX2-001 | Amphenol Cables on Demand | Amphenol CS-SATDRIVEX2-001 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 1m | |||
| CS-SASDDP8282-000.5 | Amphenol Cables on Demand | Amphenol CS-SASDDP8282-000.5 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 0.5m | |||
| CS-SASDDP8282-001 | Amphenol Cables on Demand | Amphenol CS-SASDDP8282-001 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 1m |
Documents mentioning E2V TECHNOLOGIES SAFETY
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| E2V Technologies The Mode of Operation of the EEV | E2V Technologies The Mode of Operation of the EEV IOT (Inductive Output Tube) and its Use in UHF Television Transmitters CONTENTS 1 What is an IOT?… 2 2 Where is the EEV IOT used?… 2 |
Original | ||||
| cx1151l | E2V Technologies CX1151L Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, fast recovery tetrode thyratron, specifically designed for operation under medical linac conditions, but also |
Original | ||||
| e2v technologies | E2V Technologies FX1585 Hydrogen-Filled Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, flange mounted triode thyratron designed for high voltage modulator applications. It has a rugged internally |
Original | ||||
| cx1154l | E2V Technologies CX1154L Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring fast recovery time, low jitter, firing time |
Original | ||||
| cx1154 | E2V Technologies CX1154B Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, double ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and |
Original | ||||
| e2v technologies | E2V Technologies 8503AF Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Flange mounted hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. The |
Original | ||||
| thyratron | E2V Technologies 6587 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. PULSE MODULATOR SERVICE MAXIMUM AND MINIMUM RATINGS ABRIDGED DATA (Absolute values) Hydrogen-filled triode thyratron, positive grid, for pulse |
Original | ||||
| e2v technologies | E2V Technologies CX1151 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition |
Original | ||||
| cx1135 | E2V Technologies CX1135 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for switching |
Original | ||||
| cx1154c | E2V Technologies CX1154C Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled pentode thyratron with ceramic envelope, featuring high peak current, high rate of rise of current and |
Original | ||||
| e2v technologies | E2V Technologies CX1171BC Three-Gap, Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, double-ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, |
Original | ||||
| cv372 | E2V Technologies FX227 (Service Type CV372) Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. |
Original | ||||
| fx2505 | E2V Technologies FX2505 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. Electrically superior to 4C35A. |
Original | ||||
| e2v technologies | E2V Technologies 8503 (Service Type CV6022) Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. Electrically |
Original | ||||
|
|
||||||
| e2v technologies | E2V Technologies CX1164 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for |
Original | ||||
| cx1154 | E2V Technologies CX1154 Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for |
Original | ||||
| cx1171t | E2V Technologies CX1171T Three-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, designed for operation in oil or air. |
Original | ||||
| cx1174 | E2V Technologies CX1174 Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for |
Original | ||||
| cx1622 | E2V Technologies CX1622 Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, flange mounted tetrode thyratron featuring high peak current, high rate of rise of current, low jitter and low |
Original | ||||
| cx1168 | E2V Technologies CX1168C Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift. The |
Original | ||||
| cx1171b | E2V Technologies CX1171B Three-Gap, Double Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, double ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, |
Original | ||||
| thyratron | E2V Technologies CX1171D Three-Gap Deuterium-Filled Screened Grid Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Screened grid, deuterium-filled, three-gap, high voltage thyratron with ceramic envelope, featuring high peak current, |
Original | ||||
| cx1168 | E2V Technologies CX1168 Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift. |
Original | ||||
| cx1171 | E2V Technologies CX1171 Three-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and |
Original | ||||
| cx1168b | E2V Technologies CX1168B Two-Gap, Double-Ended Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, double ended high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time |
Original | ||||