Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    E2V CCD Search Results

    E2V CCD Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LM98555CCMHX/NOPB
    Texas Instruments CCD Driver 64-HTSSOP 0 to 70 Visit Texas Instruments Buy
    LM98555CCMH/NOPB
    Texas Instruments CCD Driver 64-HTSSOP 0 to 70 Visit Texas Instruments Buy
    VSP1000DSFR
    Texas Instruments High Speed Buffer for CCD Sensor 6-SON 0 to 85 Visit Texas Instruments Buy
    VSP1000DSFT
    Texas Instruments High Speed Buffer for CCD Sensor 6-SON 0 to 85 Visit Texas Instruments Buy
    VSP1021PFB
    Texas Instruments 10-bit, 25 MSPS 1-Channel AFE for CCD Sensors 48-TQFP Visit Texas Instruments Buy

    E2V CCD Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    e2v ccd60

    Abstract: CCD60 CCD60 Back Illuminated
    Contextual Info: CCD60 Back Illuminated Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD60 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd60ccd60bie2v ccd60ccd60 back illuminated PDF

    peltier schematic

    Abstract: fenwal thermistor peltier cooler schematic 196-302LAD-002
    Contextual Info: CCD60 Front Illuminated Peltier Pack Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD60 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd60ccd60fipeltier schematicfenwal thermistor+2peltier cooler schematic196-302lad-002 PDF

    Contextual Info: CCD97-00 Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor INTRODUCTION The CCD97 is part of the L3VisionTM range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent output


    Original
    ccd97-00ccd97a1a-ccd97bi PDF

    Contextual Info: MityCCD High Performance Cameras MityCCD-E3011 APPLICATIONS • Embedded Instrumentation • Raman Spectroscopy • Low Light Imaging Applications • Portable Scientific Instrumentation • Astronomy FEATURES • High Performance Scientific Camera ƒ e2V 30-11 series


    Original
    mityccd-e3011ging-space-and-scientific-sensors/03-3011ccd30-11scientific-sensors/05-30-11dd-bi-nimo-dip+1ace-and-scientificsensors/papers/ccdtn101 PDF

    Contextual Info: CCD231-C6 Back Illuminated Scientific CCD Sensor 6144 x 6160 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    ccd231-c6ccd231a1a-777755 PDF

    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    ccd231-84ccd231a1a-765136 PDF

    CCD201-20

    Abstract: CCD201 transistor HR e2v ccd
    Contextual Info: CCD201-20 Front Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor INTRODUCTION The CCD201 is a large format sensor 41k2 in the L3VisionTM range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an


    Original
    ccd201-20ccd201transistor hre2v ccd PDF

    e2v ccd

    Abstract: e2v linear ccd E2V Technologies
    Contextual Info: E2V Technologies CCD31-20 Linear Image Sensor for Scanner Applications FEATURES TYPICAL PERFORMANCE • 4k Pixels • 12 µm2 Square Pixels • Active Length Approximately 49 mm • Wide Dynamic Range Output amplifier responsivity . 2.5 µV/ePeak signal . 540 ke-/pixel*


    Original
    ccd31-20a1a-ccd31-20e2v ccde2v linear ccd+1e2v technologies PDF

    Glenair micro

    Abstract: CCD231 CCD230 GE-56
    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    ccd231-84ccd231a1a-765136glenair micro+2ccd230ge-56 PDF

    Contextual Info: CCD201-20 Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD201 is a large format sensor >1k in the L3VisionTM range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of


    Original
    ccd201-20ccd201a1a-100013 PDF

    Contextual Info: CCD230-84 Scientific CCD Sensor Front Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    ccd230-84ccd230a1a-100049 PDF

    CCD97

    Abstract: CCD97-00 scientific imaging technologies ccd97 pinhead
    Contextual Info: CCD97–00 Front Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor INTRODUCTION The CCD97 is part of the new L3Vision2 range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd97ccd97ficcd97-00scientific imaging technologies ccd97+1pinhead PDF

    fenwal thermistor

    Abstract: 196-302LAD-002 peltier schematic peltier cooler schematic 196-302-LAD-002 CCD60 4136
    Contextual Info: CCD60 Back Illuminated Peltier Pack Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD60 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd60ccd60bifenwal thermistor196-302lad-002+4peltier schematicpeltier cooler schematic196-302-lad-0024136 PDF

    CCD97

    Abstract: CCD97-00 CCD97BI e2v ccd Scientific Imaging Technologies scientific imaging technologies ccd97 R1123 R12HV CCD97 Back Illuminated
    Contextual Info: CCD97-00 Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor INTRODUCTION The CCD97 is part of the new L3Vision2 range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd97-00ccd97ccd97bie2v ccd+5scientific imaging technologiesscientific imaging technologies ccd97r1123r12hvccd97 back illuminated PDF

    196-302LAD-002

    Abstract: fenwal thermistor CCD97 Thermistor S14 R12HV peltier cooler schematic e2v ccd scientific imaging technologies ccd97 196-302-LAD-002 peltier schematic
    Contextual Info: CCD97–00 Front Illuminated 2-Phase IMO Series Peltier Pack Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD97 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd97ccd97fi196-302lad-002fenwal thermistor+7thermistor s14r12hvpeltier cooler schematice2v ccdscientific imaging technologies ccd97196-302-lad-002peltier schematic PDF

    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    ccd231-84ccd231a1a-765136 PDF

    e2v ccd

    Abstract: Scientific Imaging Technologies CIS101 voltage follower nmos
    Contextual Info: CIS101-00-*-M05 2M Pixel CMOS Scientific Imaging Sensor For Space Applications INTRODUCTION SUMMARY SPECIFICATION The CIS101 Active Pixel Sensor is e2v’s first offering for space imaging applications with this technology. The advantages of the APS sensor over a CCD are lower power


    Original
    cis101-00-cis101a1a-766543e2v ccd+2scientific imaging technologiesvoltage follower nmos PDF

    tri linear CCD

    Abstract: Glenair micro CCD230 CCD231
    Contextual Info: CCD231-84 Back Illuminated Scientific CCD Sensor 4096 x 4096 Pixels, Four Outputs, Non-inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD231 has been designed to provide a large image area for demanding astronomical and scientific imaging


    Original
    ccd231-84ccd231a1a-765136tri linear ccd+2glenair microccd230 PDF

    fenwal thermistor

    Abstract: peltier cooler schematic CCD97 peltier schematic CCD97-00 R12HV A1A-CCD97BI
    Contextual Info: CCD97-00 Back Illuminated 2-Phase IMO Series Peltier Pack Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA 2 The CCD97 is part of the new L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent


    Original
    ccd97-00ccd97ccd97bifenwal thermistor+4peltier cooler schematicpeltier schematicr12hva1a-ccd97bi PDF

    Contextual Info: CCD230-84 Scientific CCD Sensor Back Illuminated, 4096 x 4096 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. Backilluminated spectral response combined with low readout


    Original
    ccd230-84ccd230a1a-764199 PDF

    CCD230

    Abstract: CCD230-42
    Contextual Info: CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    ccd230-42ccd230a1a-765137 PDF

    CCD230-42

    Contextual Info: CCD230-42 Front Illuminated Scientific CCD Sensor 2048 x 2048 Pixels, Four Outputs and Inverted Mode Operation INTRODUCTION This device extends e2v’s family of scientific CCD sensors. The CCD230 has been designed to provide a large image area for demanding scientific imaging applications. The low


    Original
    ccd230-42ccd230a1a-765137 PDF

    CCD60

    Abstract: e2v ccd60 8025A transistor B42
    Contextual Info: CCD60 Front Illuminated Electron Multiplying CCD Sensor INTRODUCTION The CCD60 is part of the new L3Vision2 range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent output noise of less than one electron at frame rates of 1 kHz.


    Original
    ccd60ccd60fie2v ccd608025a+1transistor b42 PDF

    196-302LAD-002

    Abstract: 196-302-LAD-002 fenwal thermistor
    Contextual Info: CCD97-00 Back Illuminated 2-Phase IMO Series Peltier Pack Electron Multiplying CCD Sensor INTRODUCTION GENERAL DATA TM The CCD97 is part of the L3Vision range of products from e2v technologies. This device uses a novel output amplifier circuit that is capable of operating at an equivalent output


    Original
    ccd97-00ccd97a1a-ccd97bi196-302lad-002+2196-302-lad-002fenwal thermistor PDF