Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    E1 BRAIN OPTO Search Results

    E1 BRAIN OPTO Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TLP3475W
    Toshiba Electronic Devices & Storage Corporation Photorelay (MOSFET output), 60 V/0.4 A, 300 Vrms, WSON4 Datasheet
    TLP3407SRA4
    Toshiba Electronic Devices & Storage Corporation Photorelay (MOSFET output, 1-form-a), 60 V/0.6 A, 300 Vrms, S-VSON16T Datasheet
    TLP3403SRHA
    Toshiba Electronic Devices & Storage Corporation Photorelay (MOSFET output, 1-form-a), 20 V/1.5 A, 500 Vrms, S-VSON4T Datasheet
    TLP3482
    Toshiba Electronic Devices & Storage Corporation Photorelay (MOSFET output, 1-form-a), 100 V/2.0 A, 500 Vrms, P-SON4 Datasheet
    TLP175A
    Toshiba Electronic Devices & Storage Corporation Photorelay (MOSFET output, 1-form-a), 60 V/0.1 A, 3750 Vrms, 4pin SO6 Datasheet

    Documents mentioning E1 BRAIN OPTO

    Document Partial File Text Tags Type PDF
    brain board
    E1 and E2 Brain Boards Features E1 Brain Board Description E1 and E2 brain boards are Ethernet-ready I/O and communication processors for digital and analog I/O systems. The E1 connects to a rack of Opto 22 G1, G4, or Quad Pak™ digital I/O modules, while the
    Original PDF
    pamux
    1357-2012.qxp:QuarkCatalogTempNew 9/5/12 11:51 AM Page 1357 15 Brain Boards TEST & MEASUREMENT Optomux and Pamux Brain Boards E1 Brain Board INTERCONNECT E2 Brain Board Optomux and Pamux Brain Boards: Opto 22 brain boards, like SNAP brains, create a truly distributed and scalable I/O system.
    Original PDF
    TECHNICAL NOTE I/O Configuration for E1 and E2
    TECHNICAL NOTE I/O Configuration for E1 and E2 Brain Boards Introduction The Opto 22 software utility ioManager™ is used to configure E1 and E2 brain boards with compatible racks and modules. (This combination of brain board with I/O rack and modules is
    Original PDF
    brain
    TECHNICAL NOTE Using E1 and E2 Brain Boards for Ethernet-to-Serial Routing Introduction Opto 22 E1 and E2 brain boards can be used to route Optomux commands between Ethernet and serial (RS-422/485) networks. Routing from a serial host to Ethernet Optomux units
    Original PDF
    brain board
    Chapter 1 E1 and E2 Architecture and Migration Overview Introduction E1 and E2 brain boards provide processing power and communications for I/O just like their predecessors, the B1 and B2 brain boards. Designed as drop-in replacement boards for the B1 or B2,
    Original PDF
    OPTOMMP PROTOCOL GUIDE Used with: SNAP PAC
    OPTOMMP PROTOCOL GUIDE Used with: SNAP PAC R-Series Controllers SNAP PAC S-Series Controllers SNAP PAC EB Brains SNAP PAC SB Brains SNAP Simple I/O™ SNAP Ethernet I/O™ SNAP Ultimate I/O™ SNAP-LCE Controller E1 Brain Board E2 Brain Board Form 1465-101028—October 2010
    Original PDF
    ioMANAGER™ USER’S GUIDE SNAP PAC R-Series
    ioMANAGER™ USER’S GUIDE SNAP PAC R-Series Controller SNAP PAC S-Series Controller SNAP Simple I/O™ SNAP Ethernet I/O™ SNAP Ultimate I/O™ SNAP-LCE Controller E1 Brain Board E2 Brain Board Form 1440-060612—June 2006 43044 Business Park Drive • Temecula • CA 92590-3614
    Original PDF
    PAC MANAGER™ USER’S GUIDE LEGACY EDITION SNAP PAC
    PAC MANAGER™ USER’S GUIDE LEGACY EDITION SNAP PAC R-Series Controllers SNAP PAC S-Series Controllers SNAP PAC EB and SB Brains SNAP Simple I/O™ SNAP Ethernet I/O™ SNAP Ultimate I/O™ E1 Brain Board E2 Brain Board Form 1714-100611—June 2010 43044 Business Park Drive • Temecula • CA 92590-3614
    Original PDF
    g4pb16h
    G4 Digital 16-Channel Header Connector Mounting Rack Features G4PB16H Description The G4PB16H I/O mounting rack accommodates up to 16 G4 I/O modules. A header connector accepts a standard 50-pin cable, the Optomux® E1 or B1, Pamux® B5, or Mistic™ B100 brain board
    Original PDF
    E1 AND E2 USER’S GUIDE Form 1563-060922—September
    E1 AND E2 USER’S GUIDE Form 1563-060922—September 2006 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080
    Original PDF
    FOR IMMEDIATE RELEASE Contact: David Crump,
    FOR IMMEDIATE RELEASE Contact: David Crump, Marketing Communications 800.321.6786 / 951.695.3010 dcrump@opto22.com Electronic copies of this release and related photos are available at www.opto22.com/company/pressroom/index.aspx Opto 22 Announces Ethernet Optomux® Brain Boards
    Original PDF
    OPTOMUX INTEGRATION KIT USER’S GUIDE Form
    OPTOMUX INTEGRATION KIT USER’S GUIDE Form 1757-080303—March, 2008 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080
    Original PDF
    opto 22 b1
    BRAIN BOARDS CLASSIC ANALOG AND DIGITAL DATA SHEET Form 463-050728 page 1/10 Part Number Description B1 16-Channel Digital Optomux Protocol Brain Board B2 16-Channel Analog Optomux Protocol Brain Board Opto 22 B1 (digital) and B2 (analog) Optomux® brain boards
    Original PDF
    pamux
    GUIDE TO TROUBLESHOOTING LEGACY OPTO 22 PRODUCTS Solid State Relays G1 (Standard) I/O G4 I/O Pamux™ Optomux™ SNAP I/O™ Modules Serial B3000 SNAP Brains Form 1104-060713—July 2006 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000
    Original PDF
    b3000
    B3000-B Serial Brain Features Description The B3000-B is a mistic serial brain designed as a modern drop-in replacement for the B3000 and is compatible with SNAP B-series mounting racks. The B3000-B has the same functionality as the B3000, except that it does not support the Optomux protocol.
    Original PDF
    OPTOMUX PROTOCOL GUIDE Form 1572-070104—January
    OPTOMUX PROTOCOL GUIDE Form 1572-070104—January 2007 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080
    Original PDF
    PAC Project Basic and Professional Comparison
    PAC Project Basic and Professional Comparison Chart The following table compares the features in version 9.0 of PAC Project™ Basic and PAC Project Professional. See Opto 22 form #1677, the SNAP PAC Controller and Brain Comparison Chart, for more details on controllers.
    Original PDF
    b3000
    B3000-B SERIAL BRAIN USER’S GUIDE Form 1781-100713—July 2010 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080
    Original PDF
    B1 AND B2 USER’S GUIDE Form 1574-060807 — August
    B1 AND B2 USER’S GUIDE Form 1574-060807 — August 2006 43044 Business Park Drive, Temecula, CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000 Fax: 800-832-OPTO (6786) or 951-695-2712 www.opto22.com Product Support Services 800-TEK-OPTO (835-6786) or 951-695-3080
    Original PDF
    SNAP PAC BRAINS USER’S GUIDE SNAP-PAC-EB1
    SNAP PAC BRAINS USER’S GUIDE SNAP-PAC-EB1 SNAP-PAC-EB2 SNAP-PAC-EB1-FM SNAP-PAC-EB2-FM SNAP-PAC-EB1-W SNAP-PAC-EB2-W SNAP-PAC-SB1 SNAP-PAC-SB2 Form 1690-100910—September 2010 43044 Business Park Drive • Temecula • CA 92590-3614 Phone: 800-321-OPTO (6786) or 951-695-3000
    Original PDF
    MODBUS/TCP PROTOCOL GUIDE For use with: SNAP PAC
    MODBUS/TCP PROTOCOL GUIDE For use with: SNAP PAC R-Series Controller SNAP PAC S-Series Controller SNAP PAC EB Brains SNAP Ethernet I/O Units SNAP Simple I/O Units SNAP Ultimate I/O Units E1 I/O Units E2 I/O Units Form 1678-070216—February 2007 43044 Business Park Drive • Temecula • CA 92590-3614
    Original PDF
    b3000
    Configuring the B3000-B The B3000-B mistic serial brain is a drop-in replacement for the obsolete B3000 serial brain. The B3000-B can be used with: • FactoryFloor controllers running OptoControl strategies • SNAP PAC S-series controllers, along with other mistic I/O units
    Original PDF
    ioProject Software Suite Features ioProject
    ioProject Software Suite Features ioProject Software Suite Description NOTE: ioProject™ is a legacy product and is not recommended for new development. For new development, use PAC Project software. For more information, see Opto 22 form #1688, SNAP PAC
    Original PDF
    PAC Project Software Suite Features Description
    PAC Project Software Suite Features Description The PAC Project Software Suite from Opto 22 provides the software you need for industrial automation, remote monitoring, and data acquisition applications in any field. One of four components of the SNAP PAC System, PAC Project software is fully integrated with
    Original PDF
    PAC Project Software Suite Features Description
    PAC Project Software Suite Features Description The PAC Project Software Suite from Opto 22 provides the software you need for industrial automation, remote monitoring, and data acquisition applications in any field. One of four components of the SNAP PAC System, PAC Project software is fully integrated with
    Original PDF