DUCT TEMPERATURE SENSOR PT100 Search Results
DUCT TEMPERATURE SENSOR PT100 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-316SMAX200-001 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-001 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 1ft | |||
| CO-316SMAX200-003 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-003 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 3ft | |||
| CO-316SMAX200-004 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-004 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 4ft | |||
| CO-316SMAX200-010 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-010 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 10ft | |||
| CO-316SMAX200-005 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-005 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 5ft |
Documents mentioning DUCT TEMPERATURE SENSOR PT100
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| duct temperature sensor | 1 Duct temperature sensor 778 FK-TP/200 for HVAC systems Duct temperature sensor for heating, ventilation and air conditioning systems – For use with controllers with Pt100 sensor inputs – In conjunction with MULTIREG and INTEGRAL RS. Use The FK-TP/200 duct temperature sensor can be used in air ducts for heating, ventilation |
Original | ||||
| transmicor | TRANSMICOR T211 HVAC RELATIVE HUMIDITY TRANSMITTER FOR DUCT MOUNTING Main characteristics • Linearised and temperature compensated humidity measurement • Measuring range: 0… 100% RH • Output signal: Humidity: analog Temperature: Pt100Ω 1/3DIN • Thin film capacitive humidity sensor |
Original | ||||
| hty79x3 | AB-5963 Specifications/Instructions Insertion Dewpoint Temperature Sensor HTY79X3 / HY79X3 General Insertion dewpoint temperature sensor HTY79X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element |
Original | ||||
| humidity sensor | AB-5967 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X6/ HY78X6 General Uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3 specially developed by Yamatake) which ensures |
Original | ||||
| humidity sensor | AB-5961 Specifications/Instructions Insertion Temperature/Humidity Sensor HTY78X3/ TY78X3/ HY78X3 General Insertion temperature/humidity sensor HTY78X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element |
Original | ||||
| transmicor | TRANSMICOR T232 series high temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0… 100 %rh, -30… +140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9…33VDC |
Original | ||||
| transmicor | TRANSMICOR T232 Series low temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0…100 %rh, -30… +85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9… 33VDC |
Original | ||||
| qpm2102 | 1 962 QPM2102D QPM2160D, QPM2162D QPM1100, QPM2100, QPM2102 Duct Air Quality Sensors QPM2160, QPM2180 QPM11… QPM21… • maintenance-free CO 2 sensing element (depending on the type) based on optical infrared absorption measurement (NDIR1) • or with VOC 2) sensing element, based on a heated tin dioxide semiconductor |
Original | ||||
| duct temperature sensor | 1 773 Duct temperature sensors QAM1… Use The sensors are used for acquiring the air temperature in heating, ventilation and air conditioning plants (e.g. in supply air, extract air or mixed air ducts). They are designed for use in connection with automation equipment, display and |
Original | ||||
| thermom | FieldIT Data Sheet 10/10-3.61 EN Resistance thermometer TSBA (SensyTemp BA R) for building automation, machine construction and environmental engineering ■ Different output signals – Pt 100 signal – 4…20 mA, temperature linear, analog – 4…20 mA, HART protocoll (on request) |
Original | ||||
| EE850 CO2 and Temperature Transmitter for Duct | EE850 CO2 and Temperature Transmitter for Duct Mounting The EE850 is designed for use in building management applications. A multiple point CO2 and temperature factory adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range. |
Original | ||||
| CombiTemp TCR6 Standard RTD temperature sensor | CombiTemp TCR6 Standard RTD temperature sensor Main features Sensor and connection in stainless steel, AISI 316L DIN form B housing Robust design Applications Industrial applications with Water systems Tanks and vessels industrial process connection |
Original | ||||
| EE210 Humidity and Temperature Transmitter for | EE210 Humidity and Temperature Transmitter for Demanding Climate Control Applications The EE210 transmitter by E+E Elektronik meets the highest requirements in demanding climate control applications. Besides highly accurate measurement of relative humidity and temperature, EE210 calculates |
Original | ||||
| TRANSMICOR T242 series high temperature RELATIVE | TRANSMICOR T242 series high temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0… 100 %rh, -30… +140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA, 0… 20mA, 2… 10V, 0… 10V (selectable with jumper), |
Original | ||||
|
|
||||||
| 10vdc | TRANSMICOR T252 Series High Temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main Features • Measuring range: 0…100%RH, -30…+140°C • Accuracy: ±2%RH, ±0,2°C • Humidity output signal: 0…1Vdc; 0…10Vdc; 0…20mA; 4…20mA; 2…10Vdc (selectable through internal switches) |
Original | ||||
| TRANSMICOR T242 series low temperature RELATIVE | TRANSMICOR T242 series low temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measurement range: 0… 100 %rh, -30…+85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA, 0… 20mA, 2… 10V, 0… 10V (selectable with jumper), |
Original | ||||
| 10vdc | TRANSMICOR T252 Series Low temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main Features • Measuring range: 0…100%RH, -30…+85°C • Accuracy: ±2%RH, ±0,2°C • Humidity output signal: 0…1Vdc; 0…10Vdc; 0…20mA; 4…20mA; 2…10Vdc (selectable through internal switches) |
Original | ||||
| System Catalog 2014 The information in this | System Catalog 2014 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. |
Original | ||||
| transmicor t220 | TRANSMICOR T220 SERIES RELATIVE HUMIDITY TRANSMITTER FOR HVAC Main characteristics • Measuring range: 0… 98 %rh, -30… +70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), 0… 1V, 0… 5V, 0… 10V, 0… 20mA (3 wire), |
Original | ||||