DUAL ELEMENT TIME-DELAY FUSE Search Results
DUAL ELEMENT TIME-DELAY FUSE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| FO-DUALLCX2MM-003 | Amphenol Cables on Demand | Amphenol FO-DUALLCX2MM-003 LC-LC Duplex Multimode 62.5/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x LC Male to 2 x LC Male 3m | |||
| FO-DUALSTLC00-001 | Amphenol Cables on Demand | Amphenol FO-DUALSTLC00-001 ST-LC Duplex Multimode 62.5/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x ST Male to 2 x LC Male 1m | |||
| FO-DUALSTLC00-004 | Amphenol Cables on Demand | Amphenol FO-DUALSTLC00-004 ST-LC Duplex Multimode 62.5/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x ST Male to 2 x LC Male 4m | |||
| FO-LSDUALSCSM-003 | Amphenol Cables on Demand | Amphenol FO-LSDUALSCSM-003 SC-SC Duplex Single-Mode 9/125 Fiber Optic Patch Cable (OFN-LS Low Smoke) - 2 x SC Male to 2 x SC Male 3m | |||
| FO-DUALLCX2MM-001 | Amphenol Cables on Demand | Amphenol FO-DUALLCX2MM-001 LC-LC Duplex Multimode 62.5/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x LC Male to 2 x LC Male 1m |
Documents mentioning DUAL ELEMENT TIME-DELAY FUSE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Low Voltage, Branch Circuit Rated Fuses Fusetron® | Low Voltage, Branch Circuit Rated Fuses Fusetron® dual-element, time-delay fuses Time-Current Characteristic Curves—Average Melt FRS-R (600V) Class RK5 Specifications Description: Dual-element, time-delay fuse – 10 seconds (minimum) at 500% rated amps. |
Original | ||||
| Bussmann® CUBEFuseTM and Fuseholder TCF & TCFH | Bussmann® CUBEFuseTM and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Catalog Symbol: TCF (Fuse) & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 100A |
Original | ||||
| Low Voltage, Branch Circuit Rated Fuses Low-Peak® | Low Voltage, Branch Circuit Rated Fuses Low-Peak® dual-element, time-delay fuses LPN-RK_SP (250V) Class RK1 LPS-RK_SP (600V) Class RK1 Now Available With Optional Indication Specifications Description: Current-limiting, dual-element, time-delay fuse; 10 seconds |
Original | ||||
| Bussmann® CUBEFuseTM and Fuseholder TCF & TCFH | Bussmann® CUBEFuseTM and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Catalog Symbol: TCF (Fuse) & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60 Amperes |
Original | ||||
| Bussmann¨ CUBEFuseª and Fuseholder TCF & TCFH | Bussmann¨ CUBEFuseª and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating Ð 600 Volts or Less Catalog Symbol: TCF (Fuse) & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60 Amperes |
Original | ||||
| Bussmann¨ CUBEFuseª and Fuseholder TCF & TCFH | Bussmann¨ CUBEFuseª and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating Ð 600 Volts or Less Catalog Symbol: TCF (Fuse) & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60 Amperes |
Original | ||||
| Edison® LENRK Class RK1 250Vac, 0.2 to 60A | Edison® LENRK Class RK1 250Vac, 0.2 to 60A Dual-Element, Time-Delay Fuses Dimensions (inches) Catalog Symbol: LENRK Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current (8 seconds for 0-30A sizes) Current-Limiting Volts: 250Vac (or less) |
Original | ||||
| Low Voltage, Branch Circuit Rated Fuses Dura-Lag™ | Low Voltage, Branch Circuit Rated Fuses Dura-Lag™ dual-element, time-delay fuses DLS-R (600V) Class RK5 Specifications Description: Dual-element, time-delay fuse – 10 seconds (minimum) at 500% rated amps. Dimensions: See page 11 for Class RK5 dimensions. |
Original | ||||
| Fusetron® FRS-R_ID Dual-Element, Time-Delay Fuses | Fusetron® FRS-R_ID Dual-Element, Time-Delay Fuses with Indication Class RK5 - 600 Volt Now Available With Optional Indication Catalog Symbol: FRS-R_ID Current-Limiting Dual-element, time-delay – 10 seconds (minimum) at 500% rated current Ratings: Volts – 600Vac (or less) |
Original | ||||
| Edison® LESRK Class RK1 600Vac, 0.25 to 60A | Edison® LESRK Class RK1 600Vac, 0.25 to 60A Dual-Element, Time-Delay Fuses Dimensions (inches) Catalog Symbol: LESRK Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 0.25 to 60A IR: 200kA RMS Sym. |
Original | ||||
| ECNR Class RK5 250Vac, 1 to 60A Dual-Element, | ECNR Class RK5 250Vac, 1 to 60A Dual-Element, Time-Delay Fuses Dimensions (inches) Catalog Symbol: ECNR Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current (8 seconds for fuses 30A or less) Current-Limiting Volts: 250Vac (or less) 125Vdc (or less) |
Original | ||||
| Fusetron® FRN-R_ID Dual-Element, Time-Delay Fuses | Fusetron® FRN-R_ID Dual-Element, Time-Delay Fuses with Indication Class RK5 - 250 Volt Catalog Symbol: FRN-R_ID Current-Limiting Dual-element, time-delay – 10 seconds (minimum) at 500% rated current (8 seconds for 0-30A sizes) Ratings: Volts – 250Vac (or less) |
Original | ||||
| 6-60a | LOW-PEAK® LPS-RK_SPI 6-60A Dual-Element, Time-Delay Fuses w/Permanent Fuse Indication Class RK1 – 600V Dimensional Data 5.5" (± 0.31) 5" (± 0.31) .81" (±0.008) 6A to 30A Catalog Symbol: LPS-RK_SPI Dual-Element, Time-Delay – 10 seconds (minimum) at 500% |
Original | ||||
| time-delay | Edison® JDL Class J 600 Volt, 70 to 600A Dual-Element, Time-Delay Fuses Dimensions (inches) Catalog Symbol: JDL Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 70 to 600A IR: 200kA RMS Sym |
Original | ||||
|
|
||||||
| fusetron | Bussmann® Fusetron® FRS-R Dual-Element, Time-Delay Fuses Class RK5 –– 600 Volt 65-600A Dimensional Data A B Dimensions (inches) Ampere Ratings 65-100 110-200 225-400 450-600 Catalog Symbol: FRS-R Dual-Element, Time-Delay – 10 seconds (minimum) at 500% |
Original | ||||
| glass fuse | 1/4" x 1-1/4" Fuses MDQ Series Dual Element, Time Delay, Glass Fuse Description • Dual element, time delay • 1/4" x 1-1/4" (6.3mm x 32mm) physical size • Glass tube, nickel-plated brass endcap construction • UL Listed product meets standard 248-14 |
Original | ||||
| fusetron | Bussmann® Fusetron® FRS-R Dual-Element, Time-Delay Fuses Class RK5 –– 600 Volt 65-600A Dimensional Data A B Dimensions (inches) Ampere Ratings 65-100 110-200 225-400 450-600 Catalog Symbol: FRS-R Dual-Element, Time-Delay – 10 seconds (minimum) at 500% |
Original | ||||
| JDL Class J 600Vac, 1 to 60A Dual-Element, | JDL Class J 600Vac, 1 to 60A Dual-Element, Time-Delay Fuses Dimensions (inches) Catalog Symbol: JDL Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 1 to 60A IR: 200kA RMS Sym. 300kA RMS Sym. (self certified) |
Original | ||||
| fusetron | Fusetron® FRS-R Dual-Element, Time-Delay Fuses Class RK5 –– 600 Volt 65-600A Dimensions - in A B Amp Ratings 65-100 110-200 225-400 450-600 Catalog Symbol: FRS-R Current-Limiting, dual-element, time-delay – 10 seconds (minimum) at 500% rated current |
Original | ||||