Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DOL STARTER WITH OVERLOAD Search Results

    DOL STARTER WITH OVERLOAD Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-54RJ45UNNE-001
    Amphenol Cables on Demand Amphenol MP-54RJ45UNNE-001 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 1ft PDF
    MP-54RJ45UNNE-002
    Amphenol Cables on Demand Amphenol MP-54RJ45UNNE-002 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 2ft PDF
    MP-52RJ45UNNE-003
    Amphenol Cables on Demand Amphenol MP-52RJ45UNNE-003 CAT5e 2-Pair RJ45 Data Cable - CAT5e 3/4/176900 Patch Cable with 8P8C RJ45 Connectors (Straight-Thru) with Pins 1, 2, 3 & 6 Populated 3ft PDF
    MP-54RJ45DNNE-010
    Amphenol Cables on Demand Amphenol MP-54RJ45DNNE-010 Cat5e STP Double Shielded Patch Cable (Braid+Foil Screened) with RJ45 Connectors - 350MHz CAT5e Rated 10ft PDF
    MP-54RJ45SNNE-025
    Amphenol Cables on Demand Amphenol MP-54RJ45SNNE-025 Cat5e STP Shielded Patch Cable (Foil-Screened) with RJ45 Connectors - 350MHz CAT5e Rated 25ft PDF

    Documents mentioning DOL STARTER WITH OVERLOAD

    Document Partial File Text Tags Type PDF
    lj7k06q706
    Product data sheet Characteristics LJ7K06Q706 enclosed DOL starter - TeSys LJ7-K - 1…1.6 A - coil 380 V AC Range of product TeSys Device short name LJ7K Product or component type Enclosed DOL starter with integral transformer Contactor application Motor control
    Original PDF
    dol starter
    Technical Specification English Powerbrake PBP Range DC Injection Production Brakes for existing DOL Starters Powerbrake PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.
    Original PDF
    PBP3-400 Description 3.0 kW complete dc injection brake unit without starter, for production braking PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.
    Original PDF
    DOL Starters with Isolator Type EXE2DI Metal
    DOL Starters with Isolator Type EXE2DI Metal Enclosure to IP65 Installation Instructions fb`VQTJQJN Issue 10 = 06.012228.10E 0808 1. Remove cover from starter by releasing catches with a screwdriver. 2. Select and fit Overload (see ratings chart below). 3.
    Original PDF
    dol starter
    Control - Direct-on-Line Starters IP66 Plastic Enclosure Three Phase 400v up to 7.5kW - 400v coil • Smoothly styled modern IP66 enclosed DOL starter, with generous cabling space for easy installation. Combined contactor/overload assembly can be unclipped from DIN rail to ease installation.
    Original PDF
    iec292
    Issued November 1990 011-044 Data Pack B Direct on line (dol) starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed
    Original PDF
    dol starter
    ADS8 Wall Chart 22/11/06 5:54 pm Page 1 ADS8 Motor starters and overload relays 9kW DOL starter without switch disconnect 25kW Star Delta starter without switch disconnect • IP 54 metalclad surface mounting enclosure, less overload relay • IP 65 moulded surface mounting enclosure, less overload relay
    Original PDF
    iec292
    Issued March 1997 232-3355 Data Pack B Direct on line (dol) starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed
    Original PDF
    bs5424
    Issued November 1990 B11044 Direct on line (dol) starters 0.5 to 10hp415Vac Features l Protected to IP54 l Robust sheet steel enclosure l 3-pole contactor to BS5424; IEC158-1 and VDE0660 l 20mm conduit entries. Robust direct on line ac starters complying with
    Original PDF
    bs5424
    B17064 Issued March 1994 Directonline(DOL)starters 0.5to10hp415VacProtectedtoIP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated enclosure environmentally protected to IP66. The
    Original PDF
    415va
    Issued March 1999 232-4493 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
    Original PDF
    iec158
    Issued March 1997 232-4493 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
    Original PDF
    bs5424
    Issued March 1994 017-064 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
    Original PDF
    4
    Issued March 1994 B17525 Electronic soft starters (Minisoft) Supplied to RS by MTE Ltd RS stock numbers 188-914, 188-920, 188-936, 188-942 Introduction Minisoft is a range of low cost soft starters and controllers for 3-phase motors up to 7.5kW. Each phase of the motor is fully controlled during the starting
    Original PDF
    Issued / Herausgegeben / Publicado / Publication
    Issued / Herausgegeben / Publicado / Publication Publicatto / Udgivet / Afgegeven / Utgiven 04/2002 V8721 0.5 to 10hp 415V Direct on Line Starter Direktstarter, 0,5-10 PS, 415 V Instruction Leaflet Bedienungsanleitung Hojas de instrucciones Feuille d’instructions
    Original PDF
    Issued July 1999 232-4572 Data Pack B Powersoft
    Issued July 1999 232-4572 Data Pack B Powersoft MN Series Data Sheet Supplied to RS by MTE Ltd (Electronic Motor Controllers 4kW to 37kW) RS stock numbers 279-4230, 279-4246, 279-4252, 279-4268 Contents 1. 2. 3. 4. 5. Introduction Technical specification Principles of operation
    Original PDF
    MEMா Enclosed Switchgear and Motor Control • Fuse-switch-disconnectors & switch disconnectors • Enclosed busbar chambers • HRC distribution fuseboards & fuses Designed with the needs of the installer and building owner in mind • Load break switches
    Original PDF
    b18433
    Issued November 1994 B18433 The MTE range of overload relays, control relays, contactors and accessories A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and
    Original PDF
    Issued March 1997 232-6051 Data Pack B Data Sheet
    Issued March 1997 232-6051 Data Pack B Data Sheet Electronic motor protection relay with integral CTs RS stock number 185-3243 and 198-4993 N L Stop L1 L2 L3 Start C 95 96 RESET 06 05 POWER SET 1 2 08 TRIP C A1 A2 TEST 3 INSTANT RESET START DELAY R1 R2 R3
    Original PDF
    Technical Specification English Issue 4 Panel
    Technical Specification English Issue 4 Panel hardware: Fault indicator lamp (amber) START button (I) STOP/RESET button (O) (overload reset) ___________________________________________________ Powerbrake PBPS Range DC Injection Production Brakes Powerbrake PBPS is a range of self-contained D.C. Injection
    Original PDF
    Issued November 1994 018-433 Data Pack B The MTE
    Issued November 1994 018-433 Data Pack B The MTE range of overload relays, control relays, contactors and accessories Data Sheet A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and
    Original PDF
    Issued March 1997 232-4831 Data Pack B The MTE
    Issued March 1997 232-4831 Data Pack B The MTE range of overload relays, control relays, contactors and accessories Data Sheet A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and
    Original PDF
    Issued November 1992 B14065 Electronic motor
    Issued November 1992 B14065 Electronic motor protection relay and accessories 110Vrelay RS stockno. 323-331 240Vrelay RS stockno. 345-448 415Vrelay RS stockno. 346-255 A solid-state overload, stall current and phase failure protection relay designed for use on three phase and
    Original PDF
    Issued March 1996 021-473 Data Pack B Data Sheet
    Issued March 1996 021-473 Data Pack B Data Sheet Electronic motor protection relay with integral CTs RS stock number 185-3243 and 198-4993 N L Stop L1 L2 L3 Start C 95 96 RESET 06 05 POWER SET 1 2 08 TRIP C A1 A2 TEST 3 INSTANT RESET START DELAY R1 R2 R3 R4
    Original PDF
    240v relay
    Issued November 1992 014-065 Data Pack B Data Sheet Electronic motor protection relay and accessories 110V relay RS stock no. 323-331 240V relay RS stock no. 345-448 415V relay RS stock no. 346-255 A solid-state overload, stall current and phase failure protection relay designed for use on three phase and
    Original PDF