DMT 02 ATEX Search Results
DMT 02 ATEX Result Highlights (2)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| ISO7021FD | Texas Instruments | Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 |
|
||
| ISO7021D | Texas Instruments | Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 |
|
Documents mentioning DMT 02 ATEX
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| tf202 | Data Sheet 10/11-8.69 EN Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels ■ Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit |
Original | ||||
| tf202 | FieldIT Data Sheet 10/11-8.69 EN Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels ■ Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit |
Original | ||||
| ellb20 | Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 2, Groups F, G Cl. II, Div. 1, Groups E, F, G (Canada) Cl. I, Zone 1, Group IIC Wet Locations ATEX Certified Enclosure Type 4X and IP66 eLLB20 Series Recessed Mount Fluorescent Luminaires Applications: eLLB Series Luminaires are used: |
Original | ||||
| tf02 | FieldIT Data Sheet 10/11-8.25 EN Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels ■ Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit |
Original | ||||
| SSB_F001-F034_GB 25.10.2003 10:08 Uhr Seite F.1 | SSB_F001-F034_GB 25.10.2003 10:08 Uhr Seite F.1 Other conductor connectors Multipin terminal strips Components for installation Overview F.2 - F.3 For 10 x 3 mm busbars Clamping yoke Busbarholders F.4 F.6 - F.5 - F.7 Mounting directly on metal plate Clamping yoke |
Original | ||||
| th202 | Data Sheet 10/11-8.64 EN Field mounted Temperature Transmitter TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation ■ Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0…5000 Ω) |
Original | ||||
| New generation Ex terminals Confirmed according | New generation Ex terminals Confirmed according to the new European Ex-Directive 94/9/EC – ATEX – A prerequisite is a notification of the manufacturer’s quality system. This exists for Weidmüller since 1997. Copies of these type examination certificates, the notification |
Original | ||||
| temperature transmitter | Operating Instructions 42/11-50 EN Temperature Transmitter TF12/TF12-Ex (head mounted) and TF212/TF212-Ex (field mounted) PROFIBUS PA Pt 100 (RTD), thermocouples 1 or 2 independent channels P R O F PROCESS FIELD BUS B U S I ® Temperature Transmitter TF12/TF12-Ex (head mounted) and |
Original | ||||
| Operating Instruction 42/18-85-EN | Operating Instruction 42/18-85-EN Electro-Pneumatic Positioner TZIDC-200, TZIDC-210, TZIDC-220 For 4… 20 mA two-wire technology, HART, PROFIBUS PA, FOUNDATION Fieldbus Blinder Text Electro-Pneumatic Positioner TZIDC-200, TZIDC-210, TZIDC-220 Operating Instruction |
Original | ||||
1794 selection guide cover.qxp 10/30/2007 3:10 PM Page 2 FLEXI/O AND FLEX EX SELECTION GUIDE 2 FLEX I/O Overview FLEX I/O offers: FLEX I/O complements all of our processor platforms and acts as local I/O for FlexLogix controllers, creating a tightly integrated control and I/O solution. |
Original | |||||
| Data Sheet 10/18-0.34-EN Electro-Pneumatic | Data Sheet 10/18-0.34-EN Electro-Pneumatic Positioner TZIDC-220 for FOUNDATION Fieldbus, flameproof enclosure Low operating cost Compact design Well-proven technology and intelligence Robust and environmentally ruggedized Wide operating temperature range -40… 85 °C |
Original | ||||
| tzidc | Data Sheet 10/18-0.33-EN Electro-Pneumatic Positioner TZIDC-210 for PROFIBUS PA, flameproof enclosure Low operating cost Compact design Well-proven technology and intelligence Robust and environmentally ruggedized Wide operating temperature range -40… 85 °C |
Original | ||||
| tzidc-200 | Data Sheet 10/18-0.32-EN Electro-Pneumatic Positioner TZIDC-200 for 4 … 20 mA two-wire technology, Flameproof (Enclosure) Low operating cost Compact design Well-proven technology and intelligence Robust and environmentally ruggedized Wide operating temperature range |
Original | ||||
| ao2000 | Continuous Gas Analyzers AO2000 Series Data Sheet 10/24 1.10 EN July 2007 One central unit and various analyzer modules Menu-driven operator interface Clear-text status messages Multiple interfaces for communication with host and – with common controls |
Original | ||||
|
|
||||||
| 1797-ie8 | FLEX Ex Analog Modules 1797-IE8, -IE8NF, and -OE8 User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local |
Original | ||||
| C A T A L O G U E E X P L O S I O N P R O T E C T | C A T A L O G U E E X P L O S I O N P R O T E C T E D 3 1 0 P R O D U C T S The CEAG Sicherheitstechnik GmbH factory in Eberbach, Germany The CEAG Nortem SA Barcelona, Spain The factory in Sheerness, UK CEAG SICHERHEITSTECHNIK GMBH Essentials, Innovations and a few words about your money |
Original | ||||
| 1797-irt8 | FLEX Ex Thermocouple/ RTD/mV Input Module Cat. No. 1797-IRT8 User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps |
Original | ||||
| analyzer | Advance Optima Continuous Gas Analyzers AO2000 Series Models AO2020, AO2040 Data Sheet 10/24 1.20 EN February 2009 One central unit and various analyzer modules Menu-driven operator interface Clear-text status messages Multiple interfaces for communication with host and |
Original | ||||
| Protection Equipment 7/2 7/7 7/19 7/21 7/22 7/23 | Protection Equipment 7/2 7/7 7/19 7/21 7/22 7/23 7/24 7/25 7/26 7/29 7/32 7/33 7/37 7/40 7/44 7/55 7/56 7/57 7/58 7/59 7/60 7/61 7/62 7/65 7/67 7/69 7/71 7/73 7/78 7/79 7/80 7/81 Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 7/82 Introduction |
Original | ||||
| Protection Equipment Circuit Breakers • Molded | Protection Equipment Circuit Breakers • Molded Case Motor Starter Protectors Reference Manual • April 2009 Low-Voltage Controls and Distribution Protection Equipment 4 7 8 10 10 13 23 24 27 27 28 29 30 32 33 33 34 34 35 42 43 44 45 46 48 49 50 51 51 52 |
Original | ||||
| Protection Equipment Circuit Breakers • | Protection Equipment Circuit Breakers • Molded-Case Circuit Breakers Reference Manual • March 2010 Industrial Controls Protection Equipment 2 4 5 7 7 10 21 22 25 25 26 27 28 30 31 31 32 32 33 40 41 42 43 44 46 47 48 49 49 50 Introduction 3RV Motor Starter Protectors/Circuit Breakers |
Original | ||||
| hart | FLEX Ex HART Analog Modules 1797-IE8H, 1797-OE8H User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 |
Original | ||||
| Integrated Device Technology, Inc. IDT MIPS | Integrated Device Technology, Inc. IDT MIPS Microprocessor Family Software Reference Manual Version 2.0 October 1996 2975 Stender Way, Santa Clara, California 95054 Telephone: (800) 345-7015 • TWX: 910-338-2070 • FAX: (408) 492-8674 Printed in U.S.A. ©1996 Integrated Device Technology, Inc. |
Original | ||||
| SAK-Series SAK-Series Appendix SAK-Series TS 35 A | SAK-Series SAK-Series Appendix SAK-Series TS 35 A SAK-Series TS 32 B SAK-Series combination foot TS 35 + TS 32 C SAK-Series for special applications D AKZ-Series TS 15 E Multi-pole terminal strips F KLBÜ shielded connection G Busbars / Terminal rails H Accessories |
Original | ||||
| INTERCONNECTS Interconnects AC Power Connectors | INTERCONNECTS Interconnects AC Power Connectors Power Cords, Power Entry Modules, Power Filters, Power Outlets and Inlets Bulgin… 1105 Qualtek… 1106, 1107 |
Original | ||||