Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DIN VDE 06 Search Results

    DIN VDE 06 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-DNPDM6MMX2-006
    Amphenol Cables on Demand Amphenol CS-DNPDM6MMX2-006 Premium 6-pin Mini-DIN 6 (MD6) Cable - Mini-DIN 6 Male to Mini-DIN 6 Male 6ft PDF
    68305-001LF
    Amphenol Communications Solutions Din Accessory Coding PDF
    65175-002LF
    Amphenol Communications Solutions Din Accessory Cover PDF
    85451-001LF
    Amphenol Communications Solutions Din Accessory Guide PDF
    BPBS8B96CAP2LF
    Amphenol Communications Solutions Din Accessory Cover set PDF

    Documents mentioning DIN VDE 06

    Document Partial File Text Tags Type PDF
    makrolon 2805
    ricos ricos ricos housing data Makrolon 2805, Lexan 161R, Polyamid 6.0 GF20 black in accordance DIN VDE 0304 T3 (IEC 707) in accordance UL 94-V-2 in accordance DIN VDE 0303 T1/06.84 CTI = 600 in accordance DIN VDE 0304 20.000 h/5.000 h 100/115 °C in accordance DIN VDE 0303 T2 (DIN 53481/>15 kV/mm)
    Original PDF
    Han D® Specifications Approvals Standards
    Han D® Specifications Approvals Standards Technical characteristics DIN VDE 0627 DIN VDE 0110 DIN EN 61 984 , , SEV DIN EN 175 301 - 801 Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The
    Original PDF
    Technical data DSTV-K Technical data Series
    Technical data DSTV-K Technical data Series DSTV-K/DSTV-K-R Standards DIN VDE 0627 DIN VDE 0110 Derating curve Approvals Inserts No. of poles Rated current Rated voltage (VDE 110/2.79 Gr. C ) Test voltage Insulations class Contact resistance Insulation resistance
    Original PDF
    elwika
    ELWIKA 4012 PG 9 ELWIKA 5012 PG 7 ELWIKA 5012 PG 9 4 5 5 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 Leitungsdose abgewinkelte Bauform, unmontiert, Leitungsabfangung mittels Klemmkàfig
    OCR Scan PDF
    Staf ® Specifications Approvals Technical
    Staf ® Specifications Approvals Technical characteristics DIN VDE 0627 DIN VDE 0110 DIN EN 61 984 , , SEV Inserts Number of contacts Electrical data acc. to DIN EN 61 984 6, 14, 20, 40 (2 x 20) 10 A Current carrying capacity The current carrying capacity is limited by maximum temperature
    Original PDF
    MEDIUM VOLTAGE DIN Fuse-Links MV DIN 17.5kV,
    MEDIUM VOLTAGE DIN Fuse-Links MV DIN 17.5kV, Current Limiting Back-Up Fuse-Links, 6.3 to 125 Amps Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 17.5TDLSJ(amp) 17.5TFLSJ(amp) 17.5TDMEJ(amp) 17.5THMEJ(amp)
    Original PDF
    Han A® Specifications Technical characteristics
    Han A® Specifications Technical characteristics DIN VDE 0627 DIN VDE 0110 DIN EN 61 984 Approvals Han A , , SEV Inserts Number of contacts 3, 4, 10, 16, 32 (2 x 16) + PE Current carrying capacity The current carrying capacity is limited by maximum temperature
    Original PDF
    12tdlej
    MEDIUM VOLTAGE DIN Fuse-Links MV DIN 12kV, Current Limiting Back-Up Fuse-Links, 6.3 to 200 Amps Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Description: Catalogue Symbol: 12TDLEJ(amp) 12THLEJ(amp) 12TKLEJ(amp)
    Original PDF
    24tdmej
    MEDIUM VOLTAGE DIN Fuse-Links 24kV, Current Limiting Back-Up Fuse-Links, 6.3 to 160 Amps MV DIN Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Description: Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp)
    Original PDF
    43625
    MEDIUM VOLTAGE DIN Fuse-Links MV DIN 17.5kV, Current Limiting Back-Up Fuse-Links, 6.3 to 125 Amps Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 17.5TDLSJ(amp) 17.5TFLSJ(amp) 17.5TDMEJ(amp) 17.5THMEJ(amp)
    Original PDF
    TM MEDIUM VOLTAGE DIN Fuse-Links MV DIN 12kV,
    TM MEDIUM VOLTAGE DIN Fuse-Links MV DIN 12kV, Current Limiting Back-Up Fuse-Links, 6.3 to 200 Amps Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 12TDLEJ(amp) 12THLEJ(amp) 12TKLEJ(amp) 12TXLEJ(amp)
    Original PDF
    Han E® Specifications Approvals Technical
    Han E® Specifications Approvals Technical characteristics Current carrying capacity DIN VDE 0627 DIN VDE 0110 DIN EN 61 984 , The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses DIN Fuses D0-type NEOZED D0 Fuse System 2–100 A, 400 (440) VAC, 250 VDC Line protection fuses - gG Motor protection fuses - aM IEC 269-3-1 DIN VDE 0636 Part 41 DIN VDE 0636 Part 301 Germany Austria D Denmark
    Original PDF
    vde 0636
    General Purpose IEC Fuses General Purpose IEC Fuses DIN Fuses D0-type NEOZED D0 Fuse System 2–100 A, 400 (440) VAC, 250 VDC Line protection fuses - gG Motor protection fuses - aM IEC 269-3-1 DIN VDE 0636 Part 41 DIN VDE 0636 Part 301 Germany Austria D Denmark
    Original PDF
    Technical data DSTV-HD Technical data Standards
    Technical data DSTV-HD Technical data Standards Series DSTV-HD/DSTV-HD-R Derating curve DIN VDE 0627 DIN VDE 0110 Approvals Temperature range Flammability class acc. UL 94 Mechanical durability - Insertion frequency Ag Rated voltage - to UL / CSA Connection method:
    Original PDF
    vde 0636
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) 400V gTr NH-fuses, 400VAC gTr with non-isolated gripping lugs, double indicator, contact blades, complying with DIN VDE 0636 Part 22, DIN VDE 0636 Part 201 Size Voltage Transformer
    Original PDF
    \4M < ► General Purpose Fuses @ DIN Fuse
    \4M < ► General Purpose Fuses @ DIN Fuse Accessories D-type (DIAZED) D Fuse System 2 - 200 A, 500 V, 690 V Line protection fuses gL-gG IEC 269-3-1 DIN VDE 0636 Part 31 DIN VDE 0636 Part 301 Dim ensions are stip u la te d in the fo llo w in g regulations:
    OCR Scan PDF
    ÄV Specifications Technical characteristics ill
    ÄV Specifications Technical characteristics ill Features DIN VDE 0627 DIN VDE 0110 • 6, 10, 16, 24 contacts • Polarized inserts Inserts 6, 10, 16, 24,32(2x16), 48 (2x24) + PE Working current 16 A 500 V Working voltage Pollution degree 3(C) Test voltage Us«
    OCR Scan PDF
    din 49440
    DATENBLATT DATA – SHEET Art. Nr. Art. No. Norm: Standard: VDE 0620 Dosen/Outlets: DIN 49440 / VDE 0620 Überspannungsschutz/Overvoltagepr.: VDE 0675, Teil 6, 1989-11, Teil A1: 1996-10, Anforderungsklasse D Beschreibung / Technische Daten: Description: Tischsteckdose SMART LINE
    Original PDF
    Series HD 60 Series HD HD-Inserts 7 - 128 Pole
    Series HD 60 Series HD HD-Inserts 7 - 128 Pole Crimp contacts Stamped or turned crimp contacts Pole number: 7, 8, 15, 16, 24, 25, 40, 50, 64, 80, 128 61 Series HD Technical data Series HD Standards DIN VDE 0627 DIN VDE 0110 Technical data Series HD Approvals
    Original PDF
    iec 947-5-2
    ELWIST 5012 PG 7 ELWIST 5012 PG 9 5 5 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 IEC 947-5-2 DIN/VDE 0600 Teil 208 A 2 Leitungsstecker, abgewinkelte Bauform, unmontiert, Leitungsabfangung mittels Klemmkafig Angled cable plug, unmounted, strain relief by clamping cage
    OCR Scan PDF
    Mainstesters Hand Tools 4952 Mainstester 220-250V
    Mainstesters Hand Tools 4952 Mainstester 220-250V AC DIN 57680-6, DIN VDE 0680-6:1972-04 Item Number 440007 65mm 3mm 0.5mm VDE approved mainstester. One piece moulded blade and handle with insulation for assured safety, high visibility permanently sealed resistance neon tube. Top quality chrome vanadium blade and nickel
    Original PDF