DELAY TIMER WITH RELAY Search Results
DELAY TIMER WITH RELAY Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| MP-54RJ45UNNE-001 | Amphenol Cables on Demand | Amphenol MP-54RJ45UNNE-001 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 1ft | |||
| MP-54RJ45UNNE-002 | Amphenol Cables on Demand | Amphenol MP-54RJ45UNNE-002 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 2ft | |||
| MP-52RJ45UNNE-003 | Amphenol Cables on Demand | Amphenol MP-52RJ45UNNE-003 CAT5e 2-Pair RJ45 Data Cable - CAT5e 3/4/176900 Patch Cable with 8P8C RJ45 Connectors (Straight-Thru) with Pins 1, 2, 3 & 6 Populated 3ft | |||
| MP-54RJ45DNNE-010 | Amphenol Cables on Demand | Amphenol MP-54RJ45DNNE-010 Cat5e STP Double Shielded Patch Cable (Braid+Foil Screened) with RJ45 Connectors - 350MHz CAT5e Rated 10ft | |||
| MP-54RJ45SNNE-025 | Amphenol Cables on Demand | Amphenol MP-54RJ45SNNE-025 Cat5e STP Shielded Patch Cable (Foil-Screened) with RJ45 Connectors - 350MHz CAT5e Rated 25ft |
Documents mentioning DELAY TIMER WITH RELAY
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Solid-state Power OFF-delay Timer H3CR-H 1/16 | Solid-state Power OFF-delay Timer H3CR-H 1/16 DIN, Analog-Set Timer with Power-OFF Delay, Four Selectable Ranges Extended power-OFF delay timer, up to 12 seconds, for S-type and 12 minutes for M-type models Forced resetting type provides a manual override of the timing function |
Original | ||||
R Solid-State Power OFF-Delay Timer H3CR-H 1/16 DIN, Analog-Set Timer with Power-OFF Delay, Four Selectable Ranges Extended power OFF-delay timer, up to 12 seconds, for S-type and 12 minutes for M-type models Forced resetting type provides a manual override of the timing function |
Original | |||||
| Electronic Timers Release Delay - True Off XF | Electronic Timers Release Delay - True Off XF DESCRIPTION OPERATION Timer with release delay function, the timer operates without auxiliary supply voltage during the timing period. Fixed time ranges: 0.1-3sec, 1-30sec. or 0.1-3min. The time is adjustable on the timer front. |
Original | ||||
| SERIES THLM RAILWAY TIME DELAY RELAY PROGRAMMABLE | SERIES THLM RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Monostable timer in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS |
Original | ||||
| thlm | SERIES THLM RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Monostable timer in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS |
Original | ||||
| SERIES THLC RAILWAY TIME DELAY RELAY PROGRAMMABLE | SERIES THLC RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Repeat cycle timer in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS |
Original | ||||
| SERIES THLC RAILWAY TIME DELAY RELAY PROGRAMMABLE | SERIES THLC RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Repeat cycle timer in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS |
Original | ||||
| Electronic timer CT-MVS.12 Multifunctional with 1 | Electronic timer CT-MVS.12 Multifunctional with 1 c/o contact Data sheet Features ½ Rated control supply voltage 24-48 V DC, 24-240 V AC ½ Multifunction timer with 10 timing functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, |
Original | ||||
| Universal Voltage Terminal Photoelectric E3JM | Universal Voltage Terminal Photoelectric E3JM Universal AC/DC Photoelectric Sensor with Built-in Timer ■ Easy-to-wire terminal block ■ Built-in timer offers selectable ON-delay, OFF-delay and one-shot ■ Relay or transistor output models ■ Polarized, through-beam and diffuse |
Original | ||||
| E3JM E3JM Universal Voltage Terminal | E3JM E3JM Universal Voltage Terminal Photoelectric E3JM Universal AC/DC Photoelectric Sensor with Built-in Timer ■ Easy-to-wire terminal block ■ Built-in timer offers selectable ON-delay, OFF-delay and one-shot ■ Relay or transistor output models ■ Polarized, through-beam and diffuse |
Original | ||||
| Electronic Off-Delay Timer True off-delay timer | Electronic Off-Delay Timer True off-delay timer with 4 ranges, selectable from the front panel. Plug-in or panel mounting ■ Timing ranges 3 secs to 12 mins ■ 4 ranges, front panel selectable ■ Indications for timing range and power on ■ DPCO output relay |
Original | ||||
| Solid-State Timer H3CA 1/16 DIN, Digital-Set | Solid-State Timer H3CA 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range ■ 8 field-selectable operation modes ■ Universal AC/DC supply voltage timers available ■ Operations include ON-delay, Repeat cycle, Signal Interval/OFF-delay, Signal-OFF delay (I and II), Interval, Cycle |
Original | ||||
| Solid-state Power OFF-delay Timer H3CR-H DIN 48 x | Solid-state Power OFF-delay Timer H3CR-H DIN 48 x 48-mm Solid-state Power OFF-delay Timer Long power OFF-delay times; S-series: up to 12 seconds, M-series: up to 12 minutes. Models with forced-reset input are available. 11-pin and 8-pin models are available. |
Original | ||||
| Solid-State Timer H3CA 1/16 DIN, Digital-Set | Solid-State Timer H3CA 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range ■ 8 field-selectable operation modes ■ Universal AC/DC supply voltage timers available ■ Operations include ON-delay, Repeat cycle, Signal Interval/OFF-delay, Signal-OFF delay (I and II), Interval, Cycle |
Original | ||||
|
|
||||||
| h3cr-h | IIH3CR-H Solid-state Power OFF-delay Timer DIN 48 x 48-mm Solid-state Power OFF-delay Timer Long power OFF-delay times; S-series: up to 12 seconds, M-series: up to 12 minutes. Models with forced-reset input are available. 11-pin and 8-pin models are available. |
Original | ||||
| timers | Solid-State Digital Timer H3CA 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range ■ 8 field-selectable operation modes ■ Universal AC/DC supply voltage timers available ■ Operations include ON-delay, Repeat cycle, Signal Interval/OFF-delay, |
Original | ||||
| Timers Programmable Quartz Timer, Multi-function | Timers Programmable Quartz Timer, Multi-function Type S 1321 • Programmable microprocessor-based quartz timer with 3-digit 7-segment display • 22 functionswithin delay on operate, interval timer, pulse continuity, symmetrical recycler, asymmetrical recycler |
Original | ||||
| thlao | SERIES THLAO RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Time delay on operate in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current |
Original | ||||
| thlor | SERIES THLOR RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Time delay on release in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current |
Original | ||||
| thlor | SERIES THLOR RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Time delay on release in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current |
Original | ||||
| SERIES THLAO RAILWAY TIME DELAY RELAY | SERIES THLAO RAILWAY TIME DELAY RELAY PROGRAMMABLE TIMER WITH SOLID STATE OUTPUT ENGINEERING DATA SHEET Time delay on operate in a hermetically sealed package Time delay programmable by wiring Output characteristics 1 solid state output Supply Direct current |
Original | ||||
| relay | Delay On Break (OFF Delay) CT-AHD Timer Relay Output Function Operation Delay On Break (OFF-delay with auxiliary voltage): Supply voltage must be applied before and during timing; the green LED glows. Upon closure of the initiate switch S1, the output relay energizes and the red LED |
Original | ||||