Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DC SPARK-OVER VOLTAGE Search Results

    DC SPARK-OVER VOLTAGE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    PQU650M-F-COVER
    Murata Manufacturing Co Ltd PQU650M Series - 3x5 Fan Cover Kit, RoHs Medical PDF
    GRM-KIT-OVER100-DE-D
    Murata Manufacturing Co Ltd 0805-1210 over100uF Cap Kit PDF
    MGN1D120603MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 12-6/-3V GAN PDF
    MGN1D050603MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 5-6/-3V GAN PDF
    MGN1S0512MC-R7
    Murata Manufacturing Co Ltd DC-DC 1W SM 5-12V GAN PDF

    DC SPARK-OVER VOLTAGE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    tip 338

    Abstract: T30-A260X dc spark-over voltage
    Contextual Info: Surge Arrester 3-Electrode-Arrester T30-A260X Ordering code: B88069X3020C253 DC spark-over voltage 1 2) 3) DC spark-over voltage 3) 5) DC spark-over voltage 2) 4) 208 . 312 208 . 338 208 . 400 V V V Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values 3)


    Original
    T30-A260X B88069X3020C253 57845/VDE tip 338 T30-A260X dc spark-over voltage PDF

    epcos 500 05

    Abstract: EPCOS 800 T30-A500X dc spark-over voltage
    Contextual Info: Surge Arrester 3-Electrode-Arrester T30-A500X Ordering code: B88069X3070C203 DC spark-over voltage 1 2) 3) DC spark-over voltage 3) 5) DC spark-over voltage 2) 4) 400 . 600 400 . 800 400 . 750 V V V Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values 3)


    Original
    T30-A500X B88069X3070C203 57845/VDE epcos 500 05 EPCOS 800 T30-A500X dc spark-over voltage PDF

    B88069X3030C253

    Abstract: T30-A90X dc spark-over voltage
    Contextual Info: Surge Arrester 3-Electrode-Arrester T30-A90X Ordering code: B88069X3030C253 DC spark-over voltage 1 2) 3) DC spark-over voltage 3) 5) DC spark-over voltage 2) 4) 72 . 108 72 . 180 72 . 230 V V V Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values 3)


    Original
    T30-A90X B88069X3030C253 57845/VDE B88069X3030C253 T30-A90X dc spark-over voltage PDF

    55A400

    Abstract: 55a350 55A90 55A75 55A420 55A470 y1500 gas discharge tube 55A300 C80AL
    Contextual Info: Gas Discharge Tube A Series 55 Nominal dc spark-over voltage Gas Discharge Tube dc spark-over voltage Vsdc (V) Vsdc (V) 55A75 75 55A90 Part No. Impulse spark-over voltage Vsi (V) Nominal impulse DC Holdover discharge current voltage 8/20 s Vh idi (KA) Nominal


    Original
    55A75 55A90 8/20s 10/1000s 00V/s 55A300 55A350 80ALSW, V80AL C80AL 55A400 55a350 55A90 55A75 55A420 55A470 y1500 gas discharge tube 55A300 C80AL PDF

    60S350

    Abstract: dc spark-over voltage 60S600 60S3 y1500 60S470
    Contextual Info: S Series 60 Nominal Alternating DC Holdover discharge Voltage current at 50Hz, 1s Nominal dc spark-over voltage Gas Discharge Tube dc spark-over voltage Impulse spark-over voltage at 1kV/µs Nominal impulse discharge current 8/20µs Vsdc (V) Vsdc (V) Vsi


    Original
    00V/s) 00V/s 60S75 60S90 60S145 60S230 60S250 150ms 60S350 dc spark-over voltage 60S600 60S3 y1500 60S470 PDF

    B470

    Abstract: b400 1500 B-470 B400 tube 805 Y1100 y1500 72BL B230 B300
    Contextual Info: B Sries Nominal dc spark-over voltage Part No. Gas Discharge Impulse spark-over Tube dc DC Holdover voltage spark-over voltage at 1kV/ s voltage Vsdc V Vsdc (V) B75 75 B90 Vsi (V) Vh Nominal impulse discharge current 8/20μs Nominal impulse discharge current


    Original
    8/20s 10/1000s 00V/s 72BLSF 72BLPF 72BLSF 72BLPF B470 b400 1500 B-470 B400 tube 805 Y1100 y1500 72BL B230 B300 PDF

    C80AL

    Abstract: y1500
    Contextual Info: A Series V80 Nominal dc spark-over voltage Part No. Gas Discharge Impulse spark-over Tube dc voltage spark-over at 1kV/ s voltage Vsdc (V) Vsdc (V) V80A75 75 V80A90 Vsi (V) DC Holdover voltage Vh Nominal impulse discharge current 8/20μs Nominal impulse


    Original
    V80A75 V80A90 8/20s 10/1000s 00V/s V80A300 V80A350 80ALSW, V80AL C80AL C80AL y1500 PDF

    Contextual Info: L Series DATA SHEET WPSPG Spark Gap Protectors – L Series Part Numbering System WPSPG 1 - 20 (2) L (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type L= Low Current (4) DC Spark-over Voltage:


    Original
    UL497B PDF

    Contextual Info: M Series DATA SHEET WPSPG Spark Gap Protectors – M Series Part Numbering System WPSPG 1 - 20 (2) M (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type M = Medium Current (4) DC Spark-over Voltage:


    Original
    UL497B E135015 10sec. PDF

    Contextual Info: H Series DATA SHEET WPSPG Spark Gap Protectors – H Series Part Numbering System WPSPG 1 - 20 (2) H (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type H= High Current (4) DC Spark-over Voltage:


    Original
    UL497B E135015 PDF

    Contextual Info: M Series DATA SHEET WPSPG Spark Gap Protectors – M Series Part Numbering System WPSPG 1 - 20 (2) M (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type M = Medium Current (4) DC Spark-over Voltage:


    Original
    UL497B E135015 10sec. PDF

    5000V 2000A

    Contextual Info: H Series DATA SHEET WPSPG Spark Gap Protectors – H Series Part Numbering System WPSPG 1 - 20 (2) H (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type H= High Current (4) DC Spark-over Voltage:


    Original
    UL497B E135015 10sec. 5000V 2000A PDF

    Contextual Info: M Series DATA SHEET WPSPG Spark Gap Protectors – M Series Part Numbering System WPSPG 1 - 20 (2) M (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type M = Medium Current (4) DC Spark-over Voltage:


    Original
    UL497B E135015 PDF

    Contextual Info: L Series DATA SHEET WPSPG Spark Gap Protectors – L Series Part Numbering System WPSPG 1 - 20 (2) L (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type L= Low Current (4) DC Spark-over Voltage:


    Original
    UL497B PDF

    Contextual Info: M Series DATA SHEET WPSPG Spark Gap Protectors – M Series Part Numbering System WPSPG 1 - 20 (2) M (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type M = Medium Current (4) DC Spark-over Voltage:


    Original
    UL497B 10sec. PDF

    SPARK GAP

    Contextual Info: L Series DATA SHEET WPSPG Spark Gap Protectors – L Series Part Numbering System WPSPG 1 - 20 (2) L (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type L= Low Current (4) DC Spark-over Voltage:


    Original
    UL497B 10sec. SPARK GAP PDF

    Contextual Info: M Series DATA SHEET WPSPG Spark Gap Protectors – M Series Part Numbering System WPSPG 1 - 20 (2) M (3) 200 (4) (1) World Products Spark Gap Protector (2) DC Spark-over Voltage Tolerance: (Example: 20=20% tolerance) (3) Series Type M = Medium Current (4) DC Spark-over Voltage:


    Original
    UL497B E135015 10sec. PDF

    T90-A230XG

    Contextual Info: Surge Arrester 3-Electrode-Arrester T90-A230XG Ordering code: B88069X6660T103 DC spark-over voltage 1 2) 3) DC spark-over voltage 2) 4) 184 . 276 176 . 550 V V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values 3) - for 50 % of measured values 3)


    Original
    T90-A230XG B88069X6660T103 57845/VDE T90-A230XG PDF

    tip 420

    Abstract: T90-A420XSMD B88069X2670T103
    Contextual Info: Surge Arrester 3-Electrode-Arrester T90-A420XSMD Ordering code: B88069X2670T103 Preliminary data DC spark-over voltage 1 2) 4) DC spark-over voltage 2) 5) 357 … 525 357 … 1200 V V Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values 4)


    Original
    T90-A420XSMD B88069X2670T103 57845/VDE0845 tip 420 T90-A420XSMD B88069X2670T103 PDF

    transistor smd code marking 420

    Abstract: smd marking blue T90-A420XSMD
    Contextual Info: Surge Arrester 3-Electrode-Arrester T90-A420XSMD Ordering code: B88069X2670T902 DC spark-over voltage 1 2) 4) DC spark-over voltage 2) 5) 357 … 525 357 … 1200 V V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values 4) - typical values of distribution 4)


    Original
    T90-A420XSMD B88069X2670T902 transistor smd code marking 420 smd marking blue T90-A420XSMD PDF

    EPCOS CS 230

    Abstract: spark gap CAS02X-067
    Contextual Info: Switching Spark Gap CAS02X-067 Ordering code: B88069X0670T502 DC spark-over voltage 1 2) 200 . 250 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    CAS02X-067 B88069X0670T502 EPCOS CS 230 spark gap CAS02X-067 PDF

    T90-A230X

    Contextual Info: Surge Arrester 3-Electrode-Arrester T90-A230X Ordering code: B88069X6700C253 DC spark-over voltage 1 2) 3) DC spark-over voltage 2) 4) 184 . 276 176 . 550 V V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values 3) - for 50 % of measured values 3)


    Original
    T90-A230X B88069X6700C253 57845/VDE T90-A230X PDF

    tip 40

    Abstract: EPCOS 800 SURGE ARRESTER T90-A230XF pm 90 arrester
    Contextual Info: Surge Arrester 3-Electrode-Arrester T90-A230XF Ordering code: B88069X6710C253 DC spark-over voltage 1 2) 3) DC spark-over voltage 2) 4) 184 . 276 176 . 550 V V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values 3) - for 50 % of measured values 3)


    Original
    T90-A230XF B88069X6710C253 tip 40 EPCOS 800 SURGE ARRESTER T90-A230XF pm 90 arrester PDF

    Contextual Info: Surge Arrester 3-Electrode-Arrester T90-A420XSMD Ordering code: B88069X2670T902 DC spark-over voltage 1 2) 4) DC spark-over voltage 2) 5) 357 … 525 357 … 1200 V V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values 4) - typical values of distribution 4)


    Original
    T90-A420XSMD B88069X2670T902 PDF