Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CONTACTOR 400 A Search Results

    CONTACTOR 400 A Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CLC400A/BPA
    Rochester Electronics LLC CLC400 - OP AMP, WIDEBAND, FAST SETTLING, CURRENT FEEDBACK - Dual marked (5962-8997001PA) PDF Buy
    TB67H400ANG
    Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/2ch/Vout(V)=50/Iout(A)=4 Datasheet
    TB67H400AHG
    Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/2ch/Vout(V)=50/Iout(A)=4 Datasheet
    TB67H400AFTG
    Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/2ch/Vout(V)=50/Iout(A)=4 Datasheet
    TB67H400AFNG
    Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/2ch/Vout(V)=50/Iout(A)=4 Datasheet

    CONTACTOR 400 A Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    star delta starter diagram

    Abstract: DILM7-10 DILM9-10 DILM17-10 DILM25-10 DILM32-10 DILM7-01 DILEM-01 wiring diagram star delta starter DILM32
    Contextual Info: Ordering Star-delta starter combinations Ordering Star-delta starter combinations Contactor combinations SDAINL Moeller HPL0211-2007/2008 Rated operational current AC-3 Max. rating for three-phase motors, 50 – 60 Hz 380 V 400 V 380 V 400 V Ie 220 V 230 V


    Original
    HPL0211-2007/2008 SDAINLM55 230V50HZ) DILM32-10 DILA-XHI20 DILM32-01 DILM25-01 star delta starter diagram DILM7-10 DILM9-10 DILM17-10 DILM25-10 DILM32-10 DILM7-01 DILEM-01 wiring diagram star delta starter DILM32 PDF

    ms35650-305t

    Abstract: 001-8708-000 MS35650 MS35338-43 ms24143 MS24143-D1 ms35338-41 ms35649 ms27997-d1 MS27997-A1
    Contextual Info: SERIES 9123 ENGINEERING DATA SHEET CONTACTOR 3 PST/NO, 25 AMP Balanced armature design Hermetically sealed 3 PST/NO Contact arrangement Meets the standards and requirements of MIL-PRF-6106 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 28 Vdc; 115 Vac, 400 Hz,


    Original
    MIL-PRF-6106 ms35650-305t 001-8708-000 MS35650 MS35338-43 ms24143 MS24143-D1 ms35338-41 ms35649 ms27997-d1 MS27997-A1 PDF

    wiring diagram contactor

    Abstract: Star Delta Control panel wiring contactor 3 phase Wiring Diagram star delta wiring diagram star delta wiring diagram with contactor ducting types electrolube PC lexan 141r star delta diagram 141R
    Contextual Info: Solid State Relays Low Noise SOLITRON With Integrated Heatsink • Single pole Solid State Contactor • Zero switching for motor and heating application • 1-, 2- and 3-phase application • Rated operational current 25 A • Rated operational voltage 230, 400 and 480 VAC


    Original
    PDF

    VDE 0660 iec 158-1

    Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
    Contextual Info: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4


    Original
    NFC63-110, VDE0660, BS5424, JEM1038 IEC60947-4 VDE 0660 iec 158-1 NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660 PDF

    3th4293

    Abstract: siemens 3th42 Ntc 500-11 3TH2 40E siemens IEC 60947-5-1 contactor siemens 3th43 3TH43 3TH42 freewheel solenoid -250/Ntc 500-11
    Contextual Info: Siemens AG 2013 Switching Devices – Contactors and Contactor Assemblies – Contactor Relays and Relays 5 Price groups PG 41A, 41B, 41H, 4N1 5/4 5/15 5/16 5/24 5/32 5/35 5/37 Introduction Contactor relays SIRIUS 3RH2 contactor relays, 4- and 8-pole SIRIUS 3RH24 latched contactor relays,


    Original
    3RH24 10-pole 3RH21 wit17024 PT787 RT17016 RT7872 01790a 01890a 3th4293 siemens 3th42 Ntc 500-11 3TH2 40E siemens IEC 60947-5-1 contactor siemens 3th43 3TH43 3TH42 freewheel solenoid -250/Ntc 500-11 PDF

    DILM15-01

    Abstract: DIL M50 moeller dil m17 moeller dil Moeller dil 2m moeller DIL 3M PKZM 1-10 PKZM4-50 MOELLER PKZM PKZM0-25
    Contextual Info: : Efficient solutions for motor control The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. DIL contactors Product information DIL M motor contactors


    Original
    PDF

    LC1-F225

    Abstract: LC1-F330 LC1-D95 LC1-F630 LC1-F185 LC1 Schneider LC1-D50 lC1F265 LC1-F265 LP1-D25
    Contextual Info: Sélection Contactors Contactors for the North American market conforming to standards UL and CSA, 20 to 120 A Standard power ratings Taille of motors 50/60 Hz Size Single-phase 3-phase 1Ø 3Ø 115 V 230 V 200 V 230 V 460 V 575 V 240 V 208 V 240 V 480 V 600 V


    Original
    AWG10 LP1-D09 LP1-D12 LP1-D18 LP1-D25 LC1-F185. LC1-F265 LC1-F630 LC1-F185 LC1-F225 LC1-F330 LC1-D95 LC1 Schneider LC1-D50 lC1F265 LP1-D25 PDF

    3TF6

    Abstract: 5611A B siemens softstarter wiring diagram 3RW40 3RP15 05-1AP30 1KB4
    Contextual Info: SIRIUS Datasheet 2009 Low Voltage Controls & Distribution Answers for industry. s Pressing, equipping, transporting. These functions run in many automated production environments. You’ll find everything that you need to switch, protect and start motors with the extensive portfolio of the modular SIRIUS system.


    Original
    H-1/187, 3TF6 5611A B siemens softstarter wiring diagram 3RW40 3RP15 05-1AP30 1KB4 PDF

    LC1-DT20

    Abstract: LA4DA1U LC1-D09 LA4DA2U LAD4RCU RC SUPPRESSOR LC1-D32 LAD4RCU Schneider LC1DT20 contactor LA4DC1U LC1D09 schneider
    Contextual Info: TeSys D-Line Contactor Accessories Coil Suppressors, Cabling Accessories www.SquareD.com For the most up-to-date information Resistor/capacitor circuit RC for reduction of “electrical noise” in AC contactor coils Effective protection of circuits sensitive to high frequency interference.


    Original
    LC1D09 LC1D32 LCtDT20 LC1DT20 8502CT9901R5/03. LC1-DT20 LA4DA1U LC1-D09 LA4DA2U LAD4RCU RC SUPPRESSOR LC1-D32 LAD4RCU Schneider LC1DT20 contactor LA4DC1U LC1D09 schneider PDF

    LA1-DN22

    Abstract: LA3DR2 LA2DT2 LA1DN22 LA2Ds2 LA1-DN31 LA3DR4 LA1DN11 LA1DN40 LA2DT0
    Contextual Info: -127V 110 -DC z AC 60H 50/ E1 E2 LA6 DK10 LA1-DN10, DN01 LA6-DK 2 LA8-DN 2.3 LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor type and rating 2/78 Te Contactors and protection relays


    Original
    -127V LA1-DN10, LA9-D93 LA9-D91 LA9-D901 LA9-D973 DX1-AP25 DX1-AP26 LA9-D730 LA9-D511 LA1-DN22 LA3DR2 LA2DT2 LA1DN22 LA2Ds2 LA1-DN31 LA3DR4 LA1DN11 LA1DN40 LA2DT0 PDF

    magnetic Contactor wiring diagrams

    Abstract: LRD 10 thermal overload relay forward reverse contactor control circuit hp 2630 datasheet
    Contextual Info: The Global Expert in Solid State Switching Technology Crydom's innovative Motion Control solutions leverage the advantage of having an all solid state design making them ideal for motor and motion control applications where precise control, long life and higher PWM frequencies are


    Original
    PDF

    7.5KW 3 phase motor 440v

    Abstract: Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor IEC158 VDE0660 11 KW 3-phase motor weight
    Contextual Info: Issued March 1994 017-064 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V 7.5KW 3 phase motor 440v Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor 11 KW 3-phase motor weight PDF

    yaskawa ERF150WJ

    Abstract: ERF 2030 45 KW 3-phase motor weight ERF-150WJ ERF150WJ
    Contextual Info: Y203-EN2-02-Katalog.book Seite 289 Mittwoch, 24. Mai 2006 2:22 14 CIMR-L7Z Varispeed L7 Made to drive lifts • • • • • • • • • • • • • • • • • One model to control AC and PM motors. Silent operation with no current de-rating.


    Original
    Y203-EN2-02-Katalog EN81-1 I22E-EN-02 yaskawa ERF150WJ ERF 2030 45 KW 3-phase motor weight ERF-150WJ ERF150WJ PDF

    lc1d12008

    Abstract: LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80
    Contextual Info: Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 θ ≤ 55 °C 1 Rated operational


    Original
    LC1-D0900ii LC1-D0910ii LC1-D0901ii LC1-D1200ii LC1-D1210ii LC1-D1201ii LC1-D1800ii LC1-D1810ii LC1-D1801ii LC1-D2500ii lc1d12008 LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80 PDF

    3RV1331-4FC10

    Abstract: 3RV1341-4JC10 3RV1321-4AC10 3RV13 3RV1331-4EC10 3RV1341-4KC10 3RV1321-1FC10 3RV1321-4BC10 3RV1331-4GC10 Contactor iec 947-4-1
    Contextual Info: 3RU11 Thermally Delayed Overload Relays up to 100 A • CLASS 10 SIRIUS 3R Technical data according to IEC 60 947-4-1 and IEC 60 947-5-1 Type 3RU11 16-. 3RU11 26-. 3RU11 36-. 3RU11 46-. Size S00 S0 S2 S3 Trip class acc. to IEC 60 947-4-1 CLASS 10


    Original
    3RU11 EX-97 3RV1331-4FC10 3RV1341-4JC10 3RV1321-4AC10 3RV13 3RV1331-4EC10 3RV1341-4KC10 3RV1321-1FC10 3RV1321-4BC10 3RV1331-4GC10 Contactor iec 947-4-1 PDF

    F0205

    Abstract: timer contactor timer vde 0110 on delay timer circuit diagram EEC contactors dc contactor DC-12 F0003 R0100 R5000
    Contextual Info: Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics 2CDC 251 060 F0003   Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width 22.5 mm Approvals 1 2 a f cULus CCC Marks


    Original
    F0003 R5000 R6000 R0100 applicat109 F0005 F0205 timer contactor timer vde 0110 on delay timer circuit diagram EEC contactors dc contactor DC-12 F0003 R0100 R5000 PDF

    MTE Contactor

    Abstract: CAP-348TP CAP-347TP CAP-346TP MAPP0021D MAPP0034C MAPP0786D capacitor 400v wiring diagram contactor 40 amp 3 phase MAPP0128D
    Contextual Info: Matrix AP 400V – 690V TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. October 2014 REV. 018 2014 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. WARNING Quick Reference ❶ Selection Guide


    Original
    CAB-26APD CAB-42AP CAB-48AP MTE Contactor CAP-348TP CAP-347TP CAP-346TP MAPP0021D MAPP0034C MAPP0786D capacitor 400v wiring diagram contactor 40 amp 3 phase MAPP0128D PDF

    kilovac

    Contextual Info: KILOVAC High Voltage Relays and Contactors Table of Contents High Voltage DC Contactors Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4, 7-5 MAP Aerospace Military Contactors MAP101 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6, 7-7


    Original
    MAP101 MAP100 MAP200 MAP201 kilovac PDF

    C25DRF340

    Abstract: C25DRJ350 C25DNJ250 C25GNF390
    Contextual Info: Definite Purpose Contactors and Starters 0–40A Compact Contactor 4.1 Product Overview—Contactors and Starters Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    V5-T4-17 V5-T4-20 V5-T4-23 V5-T4-30 V5-T4-38 V5-T4-46 V5-T4-49 V5-T4-52 V5-T4-55 V5-T4-57 C25DRF340 C25DRJ350 C25DNJ250 C25GNF390 PDF

    telemecanique contactor catalogue

    Abstract: telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D
    Contextual Info: Telemecanique D contactors and overload relays D115-59kw AC3 D150-80kw AC3 Telemecaniques’ D range is the world’s number one in contactors. Two new D range contactors are now available, expanding the range to 80kw AC3 for motor control and 200A AC1 for distribution


    OCR Scan
    D115-59kw D150-80kw telemecanique contactor catalogue telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D PDF

    LC1 contactor

    Abstract: CONTACTOR LP4 K LC1 contactor COIL LC-1 LC1 level control LC1K K09004 LC1 DC 24403-EN LC7 CONTACTOR
    Contextual Info: References 5 TeSys contactors 5 Contactors for control in category AC-1, 20 A Control circuit: a.c. 106150_1 Contactor selection according to utilisation category, see pages 24561/2 and 24565/3. Mounting on 35 mm 7 rail or Ø 4 screw fixing. Screws in the open “ready-to-tighten” position.


    Original
    24403-EN LC1 contactor CONTACTOR LP4 K LC1 contactor COIL LC-1 LC1 level control LC1K K09004 LC1 DC LC7 CONTACTOR PDF

    wiring diagram contactor 40 amp 3 phase

    Contextual Info: Rail Mount InstallationDIN Sheet SOLICON DRC Series 3 Phase & Reversing Solid State Contactors DIN Rail Mount PART NUMBER NOMENCLATURE This installation sheet includes detailed mounting and wiring instructions which apply for Crydom SOLICON DRC 3 Phase and Reversing Solid State Contactors. Be sure to


    Original
    PDF

    Contextual Info: Din Rail Mount Contactor DataSheet DRA3R Series • Three Phase Motor Reversing Contactor • Ratings of 2.4 & 4.2 Amps • Load voltage range of 48-510 VAC, 3-Phase • Fits standard 35mm DIN-RAIL • LED input status indicator, Forward green , Reverse (yellow)


    Original
    DRA3R48D2, DRA3R40D2 DRA3R48E2, DRA3R40E2 DRA3R48C2, DRA3R40C2 DRA3R48B2, DRA3R40B2 DRA3R48A2, DRA3R40A2 PDF

    KTA 3-25

    Abstract: ABB motor start wiring diagram telemecanique soft start motor control diagram telemecanique overload relay Telemecanique GV 2 soft start motor control diagram soft start ac motor control diagram overload protection of induction motor telemecanique magnetic contactor telemecanique limit switch
    Contextual Info: Motor Controller AC Semiconductor Motor Controller Types RSB.15-B • Soft starting and stopping of 3-phase squirrel cage motors • Board-level solution • Rated operational voltage: up to 480 VACrms, 50/60 Hz • Rated operational current: 15 AAC 53 b


    Original
    RSB2215-B 300VAC. KTA 3-25 ABB motor start wiring diagram telemecanique soft start motor control diagram telemecanique overload relay Telemecanique GV 2 soft start motor control diagram soft start ac motor control diagram overload protection of induction motor telemecanique magnetic contactor telemecanique limit switch PDF