Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CONTACTOR 100 A Search Results

    CONTACTOR 100 A Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    62684-402100ALF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 40 Position , Side Entry, Upper Side Contact, Surface Mount, ZIF PDF
    62684-502100ALF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 50 Position , Side Entry, Upper Side Contact, Surface Mount, ZIF PDF
    62684-501100AHLF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 50 Position , Side Entry, Lower Side Contact, Surface Mount, ZIF, Halogen free PDF
    HM2R95PA8100AALF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series, Millipacs, Right Angle Receptacle,Type DE 25,Press Fit Tail,200 Signal Pin, and ROHS Compliant PDF
    U91D121100A31
    Amphenol Communications Solutions CXP, High Speed Input Output Connector, ENHANCED FOOTPRINT PDF

    CONTACTOR 100 A Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    LEV100A4BNG

    Abstract: LEV100A5ANG 9-1618389-8 LEV100A5BNG LEV100A4BNH 400VDC LEV100 LEV100A4ANG LEV100A6ANG LEV100A6BNG 4-1618391-1
    Contextual Info: KILOVAC LEV100 Series Contactor with 1 form X contacts rated 100A continuous DESCRIPTION APPLICATIONS • Lowest cost, 100 amp, hermetically sealed DC contactor in the industry • Compact package available in side- or bottommount configurations - not position sensitive


    Original
    LEV100 48VDC 5M-GIC-CGX-8/06-066 LEV100A4BNG LEV100A5ANG 9-1618389-8 LEV100A5BNG LEV100A4BNH 400VDC LEV100A4ANG LEV100A6ANG LEV100A6BNG 4-1618391-1 PDF

    VDE 0660 iec 158-1

    Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
    Contextual Info: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4


    Original
    NFC63-110, VDE0660, BS5424, JEM1038 IEC60947-4 VDE 0660 iec 158-1 NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660 PDF

    magnetic Contactor wiring diagrams

    Abstract: LRD 10 thermal overload relay forward reverse contactor control circuit hp 2630 datasheet
    Contextual Info: The Global Expert in Solid State Switching Technology Crydom's innovative Motion Control solutions leverage the advantage of having an all solid state design making them ideal for motor and motion control applications where precise control, long life and higher PWM frequencies are


    Original
    PDF

    3th4293

    Abstract: siemens 3th42 Ntc 500-11 3TH2 40E siemens IEC 60947-5-1 contactor siemens 3th43 3TH43 3TH42 freewheel solenoid -250/Ntc 500-11
    Contextual Info: Siemens AG 2013 Switching Devices – Contactors and Contactor Assemblies – Contactor Relays and Relays 5 Price groups PG 41A, 41B, 41H, 4N1 5/4 5/15 5/16 5/24 5/32 5/35 5/37 Introduction Contactor relays SIRIUS 3RH2 contactor relays, 4- and 8-pole SIRIUS 3RH24 latched contactor relays,


    Original
    3RH24 10-pole 3RH21 wit17024 PT787 RT17016 RT7872 01790a 01890a 3th4293 siemens 3th42 Ntc 500-11 3TH2 40E siemens IEC 60947-5-1 contactor siemens 3th43 3TH43 3TH42 freewheel solenoid -250/Ntc 500-11 PDF

    204D

    Abstract: 213B
    Contextual Info: Series 209/210 AUTO-DIP ® AUTO-DIP ® Switch Automatically Insertable, Wave Solderable, Board Washable DIP Switch Features Optimized Mechanical Features • Fully sealed to withstand insertion shock, wave solder temperatures, and board washing • Positive detent seperated from contactor


    Original
    UL94V-0) 204D 213B PDF

    C25DRF340

    Abstract: C25DRJ350 C25DNJ250 C25GNF390
    Contextual Info: Definite Purpose Contactors and Starters 0–40A Compact Contactor 4.1 Product Overview—Contactors and Starters Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    V5-T4-17 V5-T4-20 V5-T4-23 V5-T4-30 V5-T4-38 V5-T4-46 V5-T4-49 V5-T4-52 V5-T4-55 V5-T4-57 C25DRF340 C25DRJ350 C25DNJ250 C25GNF390 PDF

    LA1-DN22

    Abstract: LA3DR2 LA2DT2 LA1DN22 LA2Ds2 LA1-DN31 LA3DR4 LA1DN11 LA1DN40 LA2DT0
    Contextual Info: -127V 110 -DC z AC 60H 50/ E1 E2 LA6 DK10 LA1-DN10, DN01 LA6-DK 2 LA8-DN 2.3 LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor type and rating 2/78 Te Contactors and protection relays


    Original
    -127V LA1-DN10, LA9-D93 LA9-D91 LA9-D901 LA9-D973 DX1-AP25 DX1-AP26 LA9-D730 LA9-D511 LA1-DN22 LA3DR2 LA2DT2 LA1DN22 LA2Ds2 LA1-DN31 LA3DR4 LA1DN11 LA1DN40 LA2DT0 PDF

    DILM15-01

    Abstract: DIL M50 moeller dil m17 moeller dil Moeller dil 2m moeller DIL 3M PKZM 1-10 PKZM4-50 MOELLER PKZM PKZM0-25
    Contextual Info: : Efficient solutions for motor control The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. DIL contactors Product information DIL M motor contactors


    Original
    PDF

    7.5KW 3 phase motor 440v

    Abstract: Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor IEC158 VDE0660 11 KW 3-phase motor weight
    Contextual Info: Issued March 1994 017-064 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated


    Original
    415Vac BS5424; IEC158 VDE0660 220/240V 15V/440V 7.5KW 3 phase motor 440v Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor 11 KW 3-phase motor weight PDF

    3TF6

    Abstract: 5611A B siemens softstarter wiring diagram 3RW40 3RP15 05-1AP30 1KB4
    Contextual Info: SIRIUS Datasheet 2009 Low Voltage Controls & Distribution Answers for industry. s Pressing, equipping, transporting. These functions run in many automated production environments. You’ll find everything that you need to switch, protect and start motors with the extensive portfolio of the modular SIRIUS system.


    Original
    H-1/187, 3TF6 5611A B siemens softstarter wiring diagram 3RW40 3RP15 05-1AP30 1KB4 PDF

    219-2MST

    Abstract: 204D 213B
    Contextual Info: Series 219 SMT DIP Surface mount DIP Switch — Auto Placeable Features Optimized Mechanical Features • Removable tape seal to withstand IR vapor phase or wave soldering temperatures, board washing • Positive detent separate from contactor • Low profile and medium height actuators


    Original
    686mm 11-99I 219-2MST 204D 213B PDF

    heatsink calculation

    Abstract: contactor snubber UL-94V0
    Contextual Info: ➜ Ready to use SSR for General Purpose 90mm wide Three Phase • GN technology ready to use ■ No heatsink calculation required ■ Epoxy-free design ■ Relay and contactor configuration ■ Internal transient protection by TVS ■ UL/cUL recognized, CSA and TUV approved


    Original
    25DCZ 25DCR 25BCZ 25ACZ characteris60950 heatsink calculation contactor snubber UL-94V0 PDF

    magnetic Contactor wiring diagrams

    Abstract: magnetic Contactor G9SA-321-T30 magnetic Contactor 24VDC G9SA-301 G9SA-EX031-T G9SA-321 G9SA-321-T075 G9SA-321-T15 G9SA-501
    Contextual Info: Safety Relay Unit G9SA • Four kinds of 45-mm wide Units are available: A 3-safety contact model, a 5-safety contact model, and models with 3 safety contacts and 2 OFF-delay safety contacts. Also available are 17.5-mm wide Expansion Units with 3 safety contacts and 3 OFF-delay safety contacts.


    Original
    45-mm 15-step G9SA-301, G9SA-501, G9SA321# G9SA-TH301) magnetic Contactor wiring diagrams magnetic Contactor G9SA-321-T30 magnetic Contactor 24VDC G9SA-301 G9SA-EX031-T G9SA-321 G9SA-321-T075 G9SA-321-T15 G9SA-501 PDF

    LC1-F225

    Abstract: LC1-F330 LC1-D95 LC1-F630 LC1-F185 LC1 Schneider LC1-D50 lC1F265 LC1-F265 LP1-D25
    Contextual Info: Sélection Contactors Contactors for the North American market conforming to standards UL and CSA, 20 to 120 A Standard power ratings Taille of motors 50/60 Hz Size Single-phase 3-phase 1Ø 3Ø 115 V 230 V 200 V 230 V 460 V 575 V 240 V 208 V 240 V 480 V 600 V


    Original
    AWG10 LP1-D09 LP1-D12 LP1-D18 LP1-D25 LC1-F185. LC1-F265 LC1-F630 LC1-F185 LC1-F225 LC1-F330 LC1-D95 LC1 Schneider LC1-D50 lC1F265 LP1-D25 PDF

    wiring diagram contactor

    Abstract: Star Delta Control panel wiring contactor 3 phase Wiring Diagram star delta wiring diagram star delta wiring diagram with contactor ducting types electrolube PC lexan 141r star delta diagram 141R
    Contextual Info: Solid State Relays Low Noise SOLITRON With Integrated Heatsink • Single pole Solid State Contactor • Zero switching for motor and heating application • 1-, 2- and 3-phase application • Rated operational current 25 A • Rated operational voltage 230, 400 and 480 VAC


    Original
    PDF

    es660c

    Abstract: j85500r-1 ES660 and ES660C Rectifiers es660 tyco es660c tyco CPS4048 Manual H569-422 10797 847198751 ES680
    Contextual Info: Data Sheet June 2006 CPS4048+ 48V Cabinet Power System 4100W 75A Temperature Hardened System Input: 85 Vac to 264 Vac (Autoranging) Output: -48 Vdc and Optional Ringing Generator H569-422 Battery Plant Model J85500R-1 The low-maintenance, outside-plant CPS4048+


    Original
    CPS4048+ H569-422 J85500R-1 CPS4000 19-inch x3001 DS03-038 es660c j85500r-1 ES660 and ES660C Rectifiers es660 tyco es660c tyco CPS4048 Manual 10797 847198751 ES680 PDF

    F0205

    Abstract: timer contactor timer vde 0110 on delay timer circuit diagram EEC contactors dc contactor DC-12 F0003 R0100 R5000
    Contextual Info: Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics 2CDC 251 060 F0003   Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width 22.5 mm Approvals 1 2 a f cULus CCC Marks


    Original
    F0003 R5000 R6000 R0100 applicat109 F0005 F0205 timer contactor timer vde 0110 on delay timer circuit diagram EEC contactors dc contactor DC-12 F0003 R0100 R5000 PDF

    MTE Contactor

    Abstract: CAP-348TP CAP-347TP CAP-346TP MAPP0021D MAPP0034C MAPP0786D capacitor 400v wiring diagram contactor 40 amp 3 phase MAPP0128D
    Contextual Info: Matrix AP 400V – 690V TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. October 2014 REV. 018 2014 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. WARNING Quick Reference ❶ Selection Guide


    Original
    CAB-26APD CAB-42AP CAB-48AP MTE Contactor CAP-348TP CAP-347TP CAP-346TP MAPP0021D MAPP0034C MAPP0786D capacitor 400v wiring diagram contactor 40 amp 3 phase MAPP0128D PDF

    kilovac

    Contextual Info: KILOVAC High Voltage Relays and Contactors Table of Contents High Voltage DC Contactors Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4, 7-5 MAP Aerospace Military Contactors MAP101 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6, 7-7


    Original
    MAP101 MAP100 MAP200 MAP201 kilovac PDF

    star delta wiring diagram motor start y

    Abstract: three phase diagram dol motor starter project on dol starter wiring three phase induction motor magnetic Contactor 24VDC diagram Z002 IAC53b MOTOR CONTROL SWITCHES MOELLER wiring diagram motor start delta wiring diagram dol motor starter
    Contextual Info: SMCW6151 EXTERNALLY BYPASSED THREE PHASE INDUCTION MOTOR SOLID-STATE REDUCED VOLTAGE STARTER WITH SOFTSTOP FEATURE Solid State Relays S/MOT/SMCW6151/A/23/07/99 1W240030 For Motor Control Page 1/16 GB celduc relais code SMCW6151 Farnell order code 399-6384


    Original
    SMCW6151 S/MOT/SMCW6151/A/23/07/99 1W240030 star delta wiring diagram motor start y three phase diagram dol motor starter project on dol starter wiring three phase induction motor magnetic Contactor 24VDC diagram Z002 IAC53b MOTOR CONTROL SWITCHES MOELLER wiring diagram motor start delta wiring diagram dol motor starter PDF

    lc1d12008

    Abstract: LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80
    Contextual Info: Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 θ ≤ 55 °C 1 Rated operational


    Original
    LC1-D0900ii LC1-D0910ii LC1-D0901ii LC1-D1200ii LC1-D1210ii LC1-D1201ii LC1-D1800ii LC1-D1810ii LC1-D1801ii LC1-D2500ii lc1d12008 LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80 PDF

    hp 15 star delta control 3phase

    Abstract: klixon RSC-HD0M60 klixon start relay motor klixon ptc relay star delta wiring diagram motor start RSCHD0M60 ac induction motor of 25 HP KLIXON OVERLOAD klixon* bimetal
    Contextual Info: Motor Controllers Soft Starting/Soft Stopping Types RSC -HD0M60/RSO. • Control and output modules for soft starting/stopping of 3-phase induction motors • Rated operational current: 3 x 10, 25, 50, 90, 110 AACrms • Rated operational voltage: Up to 600 VACrms


    Original
    -HD0M60/RSO. RSC-HD0M60 HP/11 HP/15 HP/22 hp 15 star delta control 3phase klixon RSC-HD0M60 klixon start relay motor klixon ptc relay star delta wiring diagram motor start RSCHD0M60 ac induction motor of 25 HP KLIXON OVERLOAD klixon* bimetal PDF

    Contextual Info: M MPCnet Remote 8DO and 16DO I/O modules for load switching Technical data Enclosure material Polyamide PA Protection class EN 60529 IP 20 Electrical connections plug-in screw-type terminal, 3-pole terminal range 0.2 to 2.5 mm² numbered Attachment to mounting rail


    Original
    8DO/16DO 03-0330-0722-03/2014-BEH-349139/2 PDF

    yaskawa ERF150WJ

    Abstract: ERF 2030 45 KW 3-phase motor weight ERF-150WJ ERF150WJ
    Contextual Info: Y203-EN2-02-Katalog.book Seite 289 Mittwoch, 24. Mai 2006 2:22 14 CIMR-L7Z Varispeed L7 Made to drive lifts • • • • • • • • • • • • • • • • • One model to control AC and PM motors. Silent operation with no current de-rating.


    Original
    Y203-EN2-02-Katalog EN81-1 I22E-EN-02 yaskawa ERF150WJ ERF 2030 45 KW 3-phase motor weight ERF-150WJ ERF150WJ PDF