Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CONTACTOR 100 A Search Results

    CONTACTOR 100 A Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DRV3946QPWPRQ1
    Texas Instruments Automotive 12-V contactor driver with current sensing and regulation 28-HTSSOP -40 to 125 Visit Texas Instruments
    62684-501100ALF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 50 Position , Side Entry, Lower Side Contact, Surface Mount, ZIF PDF
    62684-452100AHLF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 45 Position , Side Entry, Upper Side Contact, Surface Mount, ZIF, Halogen free PDF
    HM2R81PA8100AALF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series, Millipacs, Right Angle Receptacle,Type D 22 without Pegs,Press Fit Tail, , and ROHS Compliant PDF
    U90L1E1100A
    Amphenol Communications Solutions ExpressPort QSFP+, High Speed Input Output Connectors, SFP CAGE WITH HS AND CLIP. PDF

    CONTACTOR 100 A Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: 101 Series - HEAVY DUTY Contactor SPST, 100 Amp The B101 series is a heavy duty 100 amp contactor. Each contactor uses a single pole with double make or double break switching. Contacts are protected in a molded plastic cover. Combination DIN rail / panel mounting is standard. The powerful electromagnetic structure produces high contact


    Original
    240vac28vdc120vac-28vdc PDF

    LEV100A4BNG

    Abstract: LEV100A5ANG 9-1618389-8 LEV100A5BNG LEV100A4BNH 400VDC LEV100 LEV100A4ANG LEV100A6ANG LEV100A6BNG 4-1618391-1
    Contextual Info: KILOVAC LEV100 Series Contactor with 1 form X contacts rated 100A continuous DESCRIPTION APPLICATIONS • Lowest cost, 100 amp, hermetically sealed DC contactor in the industry • Compact package available in side- or bottommount configurations - not position sensitive


    Original
    lev10048vdc5m-gic-cgx-8/06-066lev100a4bng+8lev100a5ang 9-1618389-8lev100a5bnglev100a4bnh400vdclev100a4anglev100a6anglev100a6bng4-1618391-1 PDF

    ESSEX Contactor

    Abstract: LS 32 CONTACTOR LS Contactor ROTOR STAR 415 AC, 3 phase to 600V dc transformer CETA CETA25-32 120v AC to 12V dc transformer CETA12
    Contextual Info: In stallatio n - C E T A C o n tacto r General Data Contactor ratings 3-phase motor switching Contactor types CETA09-16 Max. ops/h 1200 75 a.c. 9 a.c. 100 a.c. 10 a.c. Operating times ms Closing Opening 11 - 22 a.c. 5 - 1 9 a.c. 22 - 29 a.c. 1 0- 15 a.c.


    OCR Scan
    ceta09-16ceta25-32ceta09ceta12+10ceta16ceta25ceta32essex contactorls 32 contactorls contactorrotor star415 ac, 3 phase to 600v dc transformerceta120v ac to 12v dc transformer PDF

    D-25BD

    Contextual Info: AC Relays HARTMAN Aerospace Power Products Features: • 3PDT Main Contacts • Mechanically Interlocked • 115/200 VAC, 400 Hz • 100 Amps • High Reliability • Meets many requirements of MIL-R-6106 D-25BD 3PDT, 100 Amps, 115/200 VAC, 400 Hz CONTACTOR CONFIGURATION


    Original
    mil-r-6106d-25bdnote71 PDF

    Continental RSDA

    Abstract: 741-F Miller Drive 741-F Eurotherm inc 741-F copper bus bar torque 100-280VAC
    Contextual Info: RSxA Series – Solid State Contactor DIN Rail or Panel Mounted, Single Phase CONTINENTAL INDUSTRIES INTERNATIONAL • • • • • • 50, 75 or 100 amp rating, 660V max Integrated heatsink Mounts on DIN rail or panel L.E.D. input and fault and fuse indicators


    Original
    4-28vdc100-280vac20vac741-f+5ha136739-ciicontinental rsda741-f miller driveeurotherm inc 741-fcopper bus bar torque PDF

    56 pin BGA IC Socket

    Abstract: bga 1296 yamaichi IC 120 Test Socket 176325 bga 529 54427 IC274-036274 IC274-048278 IC274-054360 IC274-056310
    Contextual Info: IC274 Series Test Contactor SMT - Spring Probe Contact Style Part Number (Details) Specifications 1MΩ min. at 500V DC Insulation Resistance: Dielectric Withstanding Voltage: 100V AC for 1 minute Contact Resistance: 200m Ω max. at 10mA/20mV max. Operating Temperature Range: –40°C to +100°C


    Original
    ic27410ma/20mv56 pin bga ic socketbga 1296+8yamaichi ic 120 test socket176325bga 52954427ic274-036274ic274-048278ic274-054360ic274-056310 PDF

    S-N25 Magnetic Contactor

    Abstract: S-N11 Magnetic Contactor SN95 mitsubishi mitsubishi contactor s-n35 s-n50 mitsubishi contactor mitsubishi contactor s-n65 SD-N35CX contactor s-n35 Mitsubishi th-n20kp UN-SA25
    Contextual Info: MITSUBISHI ELECTRIC Low Voltage Switchgear Magnetic Contactors Thermal Overload Relays Contactor Relays h (h) 2 2 1 1 (s) 1000 800 600 400 (s) 1000 800 600 400 200 200 Operating Time Operating Time A2 A1 100 80 60 40 30 20 10 8 6 4 21 1/L1 3/L2 5/L3 43 31


    Original
    d-40880rus-109240s-n25 magnetic contactors-n11 magnetic contactor+8sn95 mitsubishimitsubishi contactor s-n35s-n50 mitsubishi contactormitsubishi contactor s-n65sd-n35cxcontactor s-n35mitsubishi th-n20kpun-sa25 PDF

    Wiring Diagram kraus naimer ca10

    Abstract: CA20 kraus naimer wiring diagram for 2 position t ca10 rotary switch CA10 A300 Wiring Diagram kraus naimer ca20b kraus naimer CA 10 Kraus Naimer CA11 CA10-CA25 Ca20b CA25B
    Contextual Info: f KRAUS & NAIMER BLUE LINE SWITCHGEAR www.krausnaimer.com Catalog 100 CL Switches 10 A-20 A C, CA, CAD Switches 10 A-315 A L Switches 350 A-2400 A SINCE 1907 KRAUS & NAIMER The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than seventy-five


    Original
    n-0508s-126wiring diagram kraus naimer ca10ca20 kraus naimer wiring diagram for 2 position t+8ca10 rotary switchca10 a300wiring diagram kraus naimer ca20bkraus naimer ca 10kraus naimer ca11ca10-ca25ca20bca25b PDF

    EASY619-AC-RC

    Abstract: moeller easy412-dc-rc EASY620-DC-TC moeller easy412-dc-rc Software EASY618-DC-RC EASY618-AC-RC PC easy-pc-cab EASY618-AC-RE moeller EASY204-DP EASY620-DC-TE
    Contextual Info: 002 Moeller HPL0211-2001/2002 “Easy” Control Relays System Overview 1 Relays Contactor Relays 1 3 2 3 4 5 7 6 5 8 6 7 9 Moeller HPL0211-2001/2002 003 “Easy” Control Relays System Overview Basic units AC or DC operated Power supply AC 100 115 – 240 V, 50/60 Hz


    Original
    hpl0211-2001/2002easy619-ac-rcmoeller easy412-dc-rceasy620-dc-tc+7moeller easy412-dc-rc softwareeasy618-dc-rceasy618-ac-rcpc easy-pc-cabeasy618-ac-re moellereasy204-dpeasy620-dc-te PDF

    VDE 0660 iec 158-1

    Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
    Contextual Info: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4


    Original
    nfc63-110vde0660bs5424jem1038+8iec60947-4vde 0660 iec 158-1nfc-63110iec 158-1 vde 066032a 4 pole relay 230v aciec 947-4bs5424 iec 158-1 vde 0660dc contactor 220v PDF

    CA3-9-10

    Abstract: Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10
    Contextual Info: Accessories – Field Installable CA7 Contactors Contact Block Description NO NC Contact Arrangement Standard Contacts Catalog For use with. Number Bifurcated Contacts Catalog Price Number ➋ Price 51 61 2 CA7 all CS7-PV-02 27 CS7-PVB-02 42 CA7-30.97-✱-00


    Original
    cs7-pvb-02ca7-pv-02ca7-pvb-02cs7-pv-11+16cs7-pvb-11ca7-30ca7-pv-11ca7-pvb-11ca7-pv-s11ca7-pvb-s11ca3-9-10sprecher schuh ca3sprecher schuh ca3-23-10sprecher schuh ca3-12-10sprecher schuh ca3-16-10ca3-12-10sprecher schuhte404ca3 contactorca3-16-10 PDF

    schneider overload relay WIRING DIAGRAM

    Abstract: LRD08 GV2ME10 LRD 10 thermal overload relay GV2-P06 schneider thermal overload relay 21/schneider overload relay WIRING DIAGRAM
    Contextual Info: Solid State Contactor DataSheet DRC Series • 7.6 Amp Motor Controller rated Solid State Contactor • Load voltage range up to 530VAC • Fits standard 35mm DIN-RAIL • LED input status indicator • AC or DC control • Zero-crossing resistive loads or instantaneous turn-on (inductive loads) output


    Original
    530vacsj/t11364schneider overload relay wiring diagramlrd08+5gv2me10lrd 10 thermal overload relaygv2-p06schneider thermal overload relay21/schneider overload relay wiring diagram PDF

    siemens IEC 60947-4-1

    Abstract: siemens contactors price siemens 110 kW motors 3tb52 3RB2056 catalog for 3RT2 contactor* siemens CONTACTOR 3RH1921-1DA11 3RT1056 3RH22 wiring diagram contactor siemens
    Contextual Info: Siemens AG 2013 Switching Devices – Contactors and Contactor Assemblies – for Switching Motors 3/2 3/6 3/13 3/40 3/64 3/65 3/91 3/96 3/112 3/117 3/127 3/135 3/145 3/150 3/158 3/164 3/173 3/180 3/181 3/183 3/184 3/188 3/193 Introduction Power contactors


    Original
    3rt203rt103rt123ra27+133ra283ra293ra2910-0siemens iec 60947-4-1siemens contactors pricesiemens 110 kw motors3tb523rb2056catalog for 3rt2 contactor* siemenscontactor 3rh1921-1da113rt10563rh22wiring diagram contactor siemens PDF

    magnetic Contactor wiring diagrams

    Abstract: LRD 10 thermal overload relay forward reverse contactor control circuit hp 2630 datasheet
    Contextual Info: The Global Expert in Solid State Switching Technology Crydom's innovative Motion Control solutions leverage the advantage of having an all solid state design making them ideal for motor and motion control applications where precise control, long life and higher PWM frequencies are


    Original
    magnetic contactor wiring diagramslrd 10 thermal overload relayforward reverse contactor control circuithp 2630 datasheet PDF

    ETR4-70-A

    Abstract: EMR4-W500-2-D EMR4-F500-2 EMR4-W500-2-C ETR4-69-A EMR4-W580-2-D ETS4-VS3 TPD11DIL moeller ets4-vs3 TPE11DIL
    Contextual Info: 04/000 Moeller HPL0211-2001/2002 Relays Contactor Relays Control Relays, Contactor Relays, Electronic Timing Relays, Electronic Safety Relays, Measuring and Monitoring Relays 04/001 Moeller HPL0211-2001/2002 Control relays Contactor relays AC and DC operated


    Original
    hpl0211-2001/2002esr3-no-31esr4-no-31esr4-no-21+15esr4-nm-21esr4-nz-21esr4-nt30-30esr4-ne-42esr4-ve3-42etr4-70-aemr4-w500-2-demr4-f500-2emr4-w500-2-cetr4-69-aemr4-w580-2-dets4-vs3tpd11dilmoeller ets4-vs3tpe11dil PDF

    3th4293

    Abstract: siemens 3th42 Ntc 500-11 3TH2 40E siemens IEC 60947-5-1 contactor siemens 3th43 3TH43 3TH42 freewheel solenoid -250/Ntc 500-11
    Contextual Info: Siemens AG 2013 Switching Devices – Contactors and Contactor Assemblies – Contactor Relays and Relays 5 Price groups PG 41A, 41B, 41H, 4N1 5/4 5/15 5/16 5/24 5/32 5/35 5/37 Introduction Contactor relays SIRIUS 3RH2 contactor relays, 4- and 8-pole SIRIUS 3RH24 latched contactor relays,


    Original
    3rh2410-pole3rh21wit17024+15pt787rt17016rt787201790a01890a3th4293siemens 3th42ntc 500-113th2 40esiemens iec 60947-5-1contactor siemens 3th433th433th42freewheel solenoid-250/ntc 500-11 PDF

    ESR3-NO-31

    Abstract: TPD11DIL EMR4-W500-2-C EMR4-W580-2-D EMR4-W500-2-D VS1DIL esr4-no-31 ETR4-69-A ETR4-70-A DIL-R-44D
    Contextual Info: 04/001 Moeller HPL0211-2001/2002 Control relays Contactor relays AC and DC operated AC and DC operated System overview Page 04/002 ‘Easy’ control relays Basic units 04/006 04/006 Accessories Expansion units 04/008 04/007 Technical data 04/037 Dimensions


    Original
    hpl0211-2001/2002tri2002esr3-no-31esr4-no-31+14esr4-no-21esr4-nm-21esr4-nz-21esr4-nt30-30esr4-ne-42esr4-ve3-42tpd11dilemr4-w500-2-cemr4-w580-2-demr4-w500-2-dvs1diletr4-69-aetr4-70-adil-r-44d PDF

    CT2000

    Abstract: CT 15969 contactor IEC en 61095 ct contactor coil 24-240V 600C contactor connection thyristor contactor IEC en 15959 ct
    Contextual Info: CT2000 Contactors CT Contactor For remote switching of power, heating, lighting and small utility motors. See page 172 for applications. Technical data • ■ ■ ■ Installation in enclosures 15959 A1 1 3 A2 2 4 When installing several CT contactors side by side,


    Original
    ct2000230/240v10mm240/63a+9ct 15969contactoriec en 61095 ctcontactor coil24-240v600ccontactor connectionthyristor contactoriec en 15959 ct PDF

    siemens contactor 3rt10

    Abstract: 3RB20 SIEMENS siemens trip relay 241 siemens star delta contactor Siemens 3RT10 3RA14 SIEMENS MOTOR CONTACTOR OVERLOAD BLOCK siemens relays 3RU11 wye-delta siemens contactor
    Contextual Info: 3RA13, 3RA14 Contactor Assemblies 3RA14 Contactor Assemblies for Wye-Delta Starting 3RA14 complete units, 3 . 75 kW 3 • Overview These 3RA14 contactor assemblies for wye-delta starting are designed for standard applications. A dead interval of 50 ms on reversing is already integrated in the


    Original
    3ra133ra143ru1116-1hb0+1016-1jb0siemens contactor 3rt103rb20 siemenssiemens trip relay 241siemens star delta contactorsiemens 3rt10siemens motor contactor overload blocksiemens relays 3ru11wye-deltasiemens contactor PDF

    CAL 5-11 ABB

    Abstract: 1SBC100122C0201 star delta wiring diagram with pneumatic timer star delta timer starter diagram tp 40 da star delta timer starter diagram diode LT 42 PR 3002 WB75-A ABB CONTACTOR EH 160 ABB CONTACTOR EH 370 ABB CONTACTOR EH 250
    Contextual Info: 4/0 Accessories for Contactors and Contactor Relays Contents Accessories for A. Series and BC. Series Contactors and for Contactor Relays Auxiliary Contact Blocks - Front Mounting .


    Original
    dc-13e2110dg1sbc100122c0201cal 5-11 abb+8star delta wiring diagram with pneumatic timerstar delta timer starter diagram tp 40 dastar delta timer starter diagramdiode lt 42 pr 3002wb75-aabb contactor eh 160abb contactor eh 370abb contactor eh 250 PDF

    wiring diagram contactor

    Abstract: magnetic Contactor RELAY PLC OMRON FORWARD REVERSE 3 PHASE MOTOR wiring diagram omron reverse power relay contactor 3 phase Wiring Diagram OMRON APR-S380 magnetic Contactor wiring diagrams omron APR-s
    Contextual Info: Reverse Protection Relay APR-S Uses Voltage Detection to Determine Reverse Revolution of Three-phase Motor • Detects motor reversal due to incorrect wiring. • Direction of motor revolution is detected as soon as power is applied to the Relay. If the power is reversed, the magnetic contactor locks in the open state.


    Original
    apr-s380apr-s440wiring diagram contactormagnetic contactor+7relay plc omronforward reverse 3 phase motor wiring diagramomron reverse power relaycontactor 3 phase wiring diagramomronmagnetic contactor wiring diagramsomron apr-s PDF

    telemecanique contactor catalogue

    Abstract: LA9-D09980 LC1-F630 LC1-F225 telemecanique lc1 fh 43 LC1F150 LC1-F330 LC1-F400 lc1f LC1F500
    Contextual Info: Contactors F 3-pole contactors for motor control, 115 to 780 A Utilisation category AC-3 Control circuit : a.c. or d.c. c or a References 3-pole contactors 1 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3


    Original
    lc1-f115lc1-f150lc1-f185lc1-f225+14lc1-f265lc1-f330la9-f103lr9-f5i57f5i63f5i67telemecanique contactor cataloguela9-d09980lc1-f630telemecanique lc1 fh 43lc1f150lc1-f400lc1flc1f500 PDF

    204D

    Abstract: 213B
    Contextual Info: Series 209/210 AUTO-DIP ® AUTO-DIP ® Switch Automatically Insertable, Wave Solderable, Board Washable DIP Switch Features Optimized Mechanical Features • Fully sealed to withstand insertion shock, wave solder temperatures, and board washing • Positive detent seperated from contactor


    Original
    ul94v-0204d213b PDF

    D024 - M relay

    Abstract: CRNI63 CR-i201 d024 m relay RSTN1-14V5 CRLI110 CRNI09 RSTN4-57 CRI-310
    Contextual Info: Contents 4 Contactors Mini-contactors, Mini-contactors, AC operation DC operation CRMI05 . 6 CRMI09 . 6 11 CRMI09 . 11 Contactors up to 100 A, Contactors up to 100 A,


    Original
    crmi05crmi09crni09crni12+13crni16crni22crni32crni38crni45d024 - m relaycrni63cr-i201d024 m relayrstn1-14v5crli110rstn4-57cri-310 PDF