CONDUIT UNF Search Results
CONDUIT UNF Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
|
Contextual Info: Series 75 Metal-Core Conduit 712-844 Heavy-Duty Environmental System - Composite Conduit to Transition or End Fitting Backshell for Series 75 Metal-Core Conduit Weight-saving composite Heavy-Duty Environmental System conduit-to-transition or end itting backshell |
Original |
||
|
Contextual Info: Series 75 Metal-Core Conduit 712-845 Heavy-Duty Environmental System - Composite Conduit-to-Bulkhead Fitting for Series 75 Metal-Core Conduit Weight-saving composite Heavy-Duty Environmental System conduit-to-bulkhead itting itting How To Order 712 - 845 M |
Original |
||
712-835Contextual Info: Series 75 Metal-Core Conduit 712-835 Heavy-Duty Environmental System - Metal Environmental Conduit to Transition or End Fitting Backshell for Series 75 Metal-Core Conduit Metal Heavy-Duty Environmental System conduit-to-transition or end fitting backshell |
Original |
712-835 | |
712-844Contextual Info: Series 75 Metal-Core Conduit 712-844 Heavy-Duty Environmental System - Composite Conduit to Transition or End Fitting Backshell for Series 75 Metal-Core Conduit Weight-saving composite Heavy-Duty Environmental System conduit-to-transition or end fitting backshell |
Original |
712-844 | |
712-845Contextual Info: Series 75 Metal-Core Conduit 712-845 Heavy-Duty Environmental System - Composite Conduit-to-Bulkhead Fitting for Series 75 Metal-Core Conduit Weight-saving composite Heavy-Duty Environmental System conduit-to-bulkhead fitting fitting How To Order 712 - 845 M |
Original |
712-845 | |
712-836Contextual Info: Series 75 Metal-Core Conduit 712-836 Heavy-Duty Environmental System - Metal Advanced EMI/Sealing Conduit to Bulkhead Fitting for Series 75 Metal-Core Conduit Metal Heavy-Duty Environmental System conduit-to-bulkhead fitting, with advanced EMI shielding and environmental sealing |
Original |
712-836 | |
|
Contextual Info: Series 75 Metal-Core Conduit 712-835 Heavy-Duty Environmental System - Metal Environmental Conduit to Transition or End Fitting Backshell for Series 75 Metal-Core Conduit Metal Heavy-Duty Environmental System conduit-to-transition or end itting backshell Optional Length in |
Original |
||
|
Contextual Info: Series 75 Metal-Core Conduit 712-836 Heavy-Duty Environmental System - Metal Advanced EMI/Sealing Conduit to Bulkhead Fitting for Series 75 Metal-Core Conduit Metal Heavy-Duty Environmental System conduit-to-bulkhead itting, with advanced EMI shielding and environmental sealing |
Original |
||
|
Contextual Info: Series 75 Metal-Core Conduit 712-850 RP Plus System Conduit to Transition or End Fitting Backshell for Series 75 Metal-Core Conduit RP Plus conduit-to-transition or end itting backshell How To Order Product Series 712 Basic No. S Thread Dash No. Table III |
Original |
m24758-m24758 | |
712-850Contextual Info: Series 75 Metal-Core Conduit 712-850 RP Plus System Conduit to Transition or End Fitting Backshell for Series 75 Metal-Core Conduit RP Plus conduit-to-transition or end fitting backshell How To Order Product Series 712 Basic No. S Thread Dash No. Table III |
Original |
opti191m24758-m24758712-850 | |
712-387Contextual Info: Series 75 Metal-Core Conduit 712-387 Legacy MIL-C-24758 Superseded Conduit to Transition or End Fitting Backshell for Jacketed and/or Shielded Series 75 Metal-Core Conduit Legacy MIL-C-24758 Conduit-to-transition or end-fitting backshell (Superseded by MIL-PRF-24758A [SH]) |
Original |
mil-c-24758mil-prf-24758a712-387 | |
|
Contextual Info: Series 75 Metal-Core Conduit 712-188 Legacy MIL-C-24758 Superseded Environmental EMI/RFI Bulkhead Fitting for Series 75 Metal-Core Conduit Legacy MIL-C-24758 conduit-to-bulkhead itting (Superseded by MIL-PRF-24758A [SH]) How To Order 712 Conduit Type (Table V) |
Original |
mil-c-24758mil-prf-24758amil-c-26074 | |
712-188
Abstract: ASTM B 921
|
Original |
mil-c-24758mil-prf-24758amil-c-26074712-188+1 | |
M28840/17
Abstract: glenair 490
|
Original |
mil-prf-24758af-24758a271310zmil-24758a+2 | |
|
|
|||
CONDUIT UNFContextual Info: Adapters and Transitions 710-444 Metal Multi-Branch Transitions for Series 72 & 74 Tubing and Series 75 Conduit 710 - 444 M A24 B08 C08 Product Series "C" End Conduit Dash No. Basic Number "B" End Conduit Dash No. Finish Symbol Table II "A" End Conduit Dash No. |
Original |
20codesconduit unf | |
UNEF
Abstract: 7/16 -27 UNS 2A 24UNEF
|
Original |
unef7/16 -27 uns 2a24unef | |
UNY105
Abstract: UNY205 UNF305 UNF205 EL395 UNF215 CROUSE-HINDS UNF UNF105 UNY506 UNY215
|
Original |
uny105uny205unf305unf205+6 | |
entraco
Abstract: glenair fittings and entraco conduit Glenair entraco Glenair 06324 MIL-STD-1344 mil-c-81511 Glenair mil-c-26500 MIL-C-28840 MIL-C-83723
|
Original |
717-148-abentracoglenair fittings and entraco conduitglenair entraco+7 | |
ETFEContextual Info: Conduit Assemblies Legacy Adapter to Adapter Pre-Terminated Assemblies Series 72 & 74 Tubing & Series 75 Conduit For use with adapters and transitions shown in Table III FOR ADAPTER-TO-ADAPTER APPLICATIONS Product Series 750 = Series 75 Metal Core Conduit |
Original |
etfe | |
glenair fittings and entraco conduit
Abstract: Glenair entraco RG-233 RG233 SHIPBOARD CONDUIT R/SHIPBOARD CONDUIT
|
Original |
m24758mil-c-24758glenair fittings and entraco conduitglenair entraco+4 | |
N 413 M
Abstract: 445 Glenair Transitions
|
Original |
710-118ma20b12c32n 413 m445 glenairtransitions | |
712-849Contextual Info: Series 75 Metal-Core Conduit 712-849 RP Plus System Low-Profile Bulkhead Fitting with Shrink Boot Accomodation for Series 75 Metal-Core Conduit RP Plus conduit-to-bulkhead fitting, environmental How To Order Product Series 712 Basic No. S Bulkhead Size Table III |
Original |
m24758-m24758712-849 | |
|
Contextual Info: Adapters and Transitions Series 72, 74, & 75 Transitions 710 - 077 M A20 B12 C12 D12 A Product Series Material A = Aluminum B = Brass C = Stainless Steel Basic Number Finish Symbol Table II "D" End Conduit Dash Number "C" End Conduit Dash Number "A" End Conduit Dash No. |
Original |
||
tube conduit
Abstract: CONDUIT UNF 2-12UNF 712-462
|
Original |
dimen26500-hourtube conduitconduit unf+2 | |