COIL L10 Search Results
COIL L10 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DRV201YFMR | Texas Instruments | 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 |
|
|
|
| DRV201AYMBR | Texas Instruments | 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 |
|
|
|
| DRV201YFMT | Texas Instruments | 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 |
|
||
| DRV201AYMBRB | Texas Instruments | 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 |
|
|
|
| DRV201YMBR | Texas Instruments | 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 |
|
|
Documents mentioning COIL L10
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| vb024 | VB024 HIGH VOLTAGE IGNITION COIL DRIVER POWER IC ■ TYPE V CL IC Id VB024 400 V 8A 100 mA PRIMARY COIL CURRENT INTERNALLY SET PRIMARY COIL VOLTAGE INTERNALLY SET AUTOMATIC SHUT-OFF AT MAX CURRENT LOGIC LEVEL COMPATIBLE INPUT DIGITAL SIGNAL FEEDBACK TO INDICATE |
Original | ||||
| vb024 | VB024 HIGH VOLTAGE IGNITION COIL DRIVER POWER IC ■ TYPE V CL IC Id VB024 400 V 8A 100 mA PRIMARY COIL CURRENT INTERNALLY SET PRIMARY COIL VOLTAGE INTERNALLY SET AUTOMATIC SHUT-OFF AT MAX CURRENT LOGIC LEVEL COMPATIBLE INPUT DIGITAL SIGNAL FEEDBACK TO INDICATE |
Original | ||||
| rz 7 S C S -T H O M S O N VB024 HIGH VOLTAGE | rz 7 S C S -T H O M S O N VB024 HIGH VOLTAGE IGNITION COIL DRIVER POWER 1C… TYP E VCL ic Id VB024 400 V 8 A 100 mA PRIMARY COIL CURRENT INTERNALLY SET PRIMARY COIL VOLTAGE INTERNALLY SET AUTOMATIC SHUT-OFF AT MAX CURRENT LOGIC LEVEL COMPATIBLE INPUT |
OCR Scan | ||||
| NEW CURRENT SENSORS COIL BUILT-IN TYPE L10P TYPE | NEW CURRENT SENSORS COIL BUILT-IN TYPE L10P TYPE ● 小型コイル内蔵タイプ ● Compact, ● オンボードタイプ ● On-board coil-interrated type. type. ● Standardized from 3AT up to 30AT ● Volume-less ● Low cost ● 3AT∼30ATまで標準化 |
Original | ||||
| ignition timing | ELECTRONIC IGNITION TIMING The ULQ2460A, ULQ2460C, and ULQ2460LW electronic ignition timing circuits are intended to interface between conventional electro magnetic pick-ups, a computer-controlled electronic spark timing (EST) computer, and a high-efficiency ignition coil. |
OCR Scan | ||||
| passive keyless entry system | TDK’s Transponder Coils TPL Series for Tire Pressure Monitoring Systems for Passive Keyless Entry Systems for Immobilizer Systems TDK Electronics Europe GmbH Copyright 2004 by TDK Electronics Europe GmbH. All rights reserved. SMD Transponder coil for TPMS, PKE and Immobilizer |
Original | ||||
| an710 | AN710 Antenna Circuit Design for RFID Applications Author: Youbok Lee, Ph.D. Microchip Technology Inc. REVIEW OF A BASIC THEORY FOR RFID ANTENNA DESIGN INTRODUCTION Current and Magnetic Fields Passive RFID tags utilize an induced antenna coil voltage for operation. This induced AC voltage is |
Original | ||||
| dc solenoid | Model L-10 DC Solenoid Tubular, Pull Type 2110 Queensway Searcy, AR 72143 Phone 501-268-6877 Website: www.pontiaccoil.com Pontiac Coil - Arkansas is an ISO 9001:2000 Certified Company *Resistance values are ± 10% at 25°C Model Code Part No. L-10PL012D-C-2 F0481A |
Original | ||||
| Ledex® Rotary Solenoids Size 2E Precision | Ledex® Rotary Solenoids Size 2E Precision Elongated Coil Performance Specifications ROTARY Solenoids Stroke 25° 35° 45° Holding Torque2 (lb-in) 0.5 * 0.3 Starting Torque (lb-in)1 @ 20°C Maximum Duty Cycle 100% 50% 25% 10% 5% 0.2 0.4 0.7 1.4 1.7 0.2 0.3 |
Original | ||||
| MITSUMI Power Inductors C8-H, C10-H, C12-H Series | MITSUMI Power Inductors C8-H, C10-H, C12-H Series OUTLINE High current and low resistance of choke coil have been lined up for note PC and amusement equipment. This series is two ranks size down from Cxx-K series. C8-H3.5R C10-H3.5R C12-H3R C8-H5R C10-H5R |
Original | ||||
| MITSUMI Power Inductors C8-H, C10-H, C12-H Series | MITSUMI Power Inductors C8-H, C10-H, C12-H Series OUTLINE High current and low resistance of choke coil have been lined up for note PC and amusement equipment. This series is two ranks size down from Cxx-K series. C8-H3.5R C10-H3.5R C12-H3R C8-H5R C10-H5R |
Original | ||||
| MITSUMI Power Inductors C8-H, C10-H, C12-H Series | MITSUMI Power Inductors C8-H, C10-H, C12-H Series OUTLINE High current and low resistance of choke coil have been lined up for note PC and amusement equipment. This series is two ranks size down from Cxx-K series. C8-H3.5R C10-H3.5R C12-H3R C8-H5R C10-H5R |
Original | ||||
| MITSUMI Power Inductors C8-H, C10-H, C12-H Series | MITSUMI Power Inductors C8-H, C10-H, C12-H Series OUTLINE High current and low resistance of choke coil have been lined up for note PC and amusement equipment. This series is two ranks size down from Cxx-K series. C8-H3.5R C10-H3.5R C12-H3R C8-H5R C10-H5R |
Original | ||||
| MITSUMI Power Inductors C8-H, C10-H, C12-H Series | MITSUMI Power Inductors C8-H, C10-H, C12-H Series OUTLINE High current and low resistance of choke coil have been lined up for note PC and amusement equipment. This series is two ranks size down from Cxx-K series. C8-H3.5R C10-H3.5R C12-H3R C8-H5R C10-H5R |
Original | ||||
|
|
||||||
| en50205 | General Purpose Relays Safety Relay SR6 sensitive ■ 6 pole safety relay with either 4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts ■ Forcibly guided contacts according to EN50205 ■ Rated current 8 A ■ coil power 800 mW ■ RoHS compliant (Directive 2002/95/EC) |
Original | ||||
| Ledex® Rotary Solenoids Size 5S Precision | Ledex® Rotary Solenoids Size 5S Precision Standard Coil ROTARY Solenoids Performance Specifications Stroke 25° 35° 45° 55° 671⁄2° 75° 95° 110° Holding Torque2 (lb-in) 5.0 * 3.0 * * * 2.0 * Starting Torque (lb-in)1 @ 20°C Maximum Duty Cycle 100% 50% 25% 10% |
Original | ||||
| General Purpose Relays Safety Relay SR6 ■ 6 pole | General Purpose Relays Safety Relay SR6 ■ 6 pole safety relay with either 4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts ■ Forcibly guided contacts according to EN50205 ■ Rated current 8 A ■ coil power 800 mW or 1200 mW ■ RoHS compliant (Directive 2002/95/EC) |
Original | ||||
| schrack | SCHRACK General Purpose Relays Safety Relay SR6 n 6 pole safety relay with either 4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts n Forcibly guided contacts according to EN50205 n Rated current 8 A n Coil power 800 mW or 1200 mW Applications Emergency shut-off, press control, machine control, elevator |
Original | ||||
| schrack | SCHRACK General Purpose Relays Safety Relay SR6 ■ 6 pole safety relay with either 4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts ■ Forcibly guided contacts according to EN50205 ■ Rated current 8 A ■ Coil power 800 mW or 1200 mW Applications Emergency shut-off, press control, machine control, elevator |
Original | ||||
| SCHRACK General Purpose Relays Safety Relay SR6 ■ | SCHRACK General Purpose Relays Safety Relay SR6 ■ 6 pole safety relay with either 4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts ■ Forcibly guided contacts according to EN50205 ■ Rated current 8 A ■ Coil power 800 mW or 1200 mW Applications Emergency shut-off, press control, machine control, elevator |
Original | ||||
| r | Berger US 14R-Mont-JK.qxp 23.09.2008 22:46 Seite 1 Catalog 9-1773450-2 Revised 9-08 General Purpose Relays Tyco Electronics Austria GmbH Pilzgasse 33 1210 Vienna Austria Phone: +43 1 90560-0 Fax: +43 1 90560-1333 www.tycoelectronics.com % Tyco Electronics Corporation |