CODE FIR Search Results
CODE FIR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TC4511BP | Toshiba Electronic Devices & Storage Corporation | CMOS Logic IC, BCD-to-7-Segment Decoder, DIP16 | Datasheet | ||
| 68305-001LF | Amphenol Communications Solutions | Din Accessory Coding | |||
| 65197-001LF | Amphenol Communications Solutions | Din Accessory Coding Part | |||
| 70275-001LF | Amphenol Communications Solutions | 70275-001LF-METRAL FEM CODING PART | |||
| 91290-101LF | Amphenol Communications Solutions | Board-to-Board Coding System, Receptacle Key, LF |
Documents mentioning CODE FIR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| EG Series Part Marking / Date Code Reference Date | EG Series Part Marking / Date Code Reference Date code explanation: Date code indicates date (Y,M,D) of production. 1) First Digit: indicates last digit of year as follows. Code Year 1 2001 2 2002 3 2003 : : 2) Second Digit: indicates month as follows. Code |
Original | ||||
| APPLICATION NOTE R8C/Tiny Series General-purpose | APPLICATION NOTE R8C/Tiny Series General-purpose Program for Converting from 1-byte HEX Code to BCD Code 1. Abstract This program converts 1-byte HEX code into 2-byte BCD code. 2. Introduction This program converts 1-byte HEX code into 2-byte BCD code. Set the HEX code in R1L. The BCD code is output |
Original | ||||
| APPLICATION NOTE M16C/60 Series and M16C/20 | APPLICATION NOTE M16C/60 Series and M16C/20 Series General-purpose Program for Converting from 1-byte HEX Code to BCD Code 1. Abstract This program converts 1-byte HEX code into 2-byte BCD code. 2. Introduction This program converts 1-byte HEX code into 2-byte BCD code. Set the HEX code in R1L. The BCD code is output |
Original | ||||
| dicap | DICAP ® dielectric laboratories High performance single layer ceramic capacitors for RF and Microwave and Millimeter Wave applications. Part Number D 15 BU 101 K 5 P X Product Code Test Code Size Code Termination Code Material Code Voltage Rating/ Thickness Code |
Original | ||||
| APPLICATION NOTE R8C/Tiny Series General-purpose | APPLICATION NOTE R8C/Tiny Series General-purpose Program for Converting from 4-byte BCD Code to HEX Code 1. Abstract This program converts 4-byte BCD code into 4-byte HEX code. 2. Introduction This program converts 4-byte BCD code into 4-byte HEX code. Set the BCD code in R2 and R0 beginning with the |
Original | ||||
| APPLICATION NOTE R8C/Tiny Series General-purpose | APPLICATION NOTE R8C/Tiny Series General-purpose Program for Converting from 4-byte HEX Code to BCD Code 1. Abstract This program converts 4-byte HEX code into 5-byte BCD code. 2. Introduction This program converts 4-byte HEX code into 5-byte BCD code. Set the HEX code in R3 and R1 beginning with the |
Original | ||||
| APPLICATION NOTE M16C/60 Series and M16C/20 | APPLICATION NOTE M16C/60 Series and M16C/20 Series General-purpose Program for Converting from 4-byte HEX Code to BCD Code 1. Abstract This program converts 4-byte HEX code into 5-byte BCD code. 2. Introduction This program converts 4-byte HEX code into 5-byte BCD code. Set the HEX code in R3 and R1 beginning with the |
Original | ||||
| APPLICATION NOTE M16C/60 Series and M16C/20 | APPLICATION NOTE M16C/60 Series and M16C/20 Series General-purpose Program for Converting from 4-byte BCD Code to HEX Code 1. Abstract This program converts 4-byte BCD code into 4-byte HEX code. 2. Introduction This program converts 4-byte BCD code into 4-byte HEX code. Set the BCD code in R2 and R0 beginning with the |
Original | ||||
| en60062 | GENERAL INFORMATION PRODUCT CODE SYSTEM AND DATE CODE PRODUCT CODE SYSTEM DATE CODE The part number, comprising 14 digits, is formed as follows: 1 2 3 6 □ 7 8 9 10 11 □□ 12 13 14 (according to EN60062) Year Code letter Month Code letter* 1997 1998 1999 |
OCR Scan | ||||
| 43 NISSEI NISSEI PART NUMBER CODE SYSTEM (1) (2) | 43 NISSEI NISSEI PART NUMBER CODE SYSTEM (1) (2) Type (3) Lead Internal con fig use uration (4) Rated voltage (5) CapacitanceCapacitance tolerance value Model Code (Standard "0000") (6) Lead Dimensions Packing Mode code *2 (2) Lead configuration code Code |
Original | ||||
| THIS DRAWING IS UNPUBLISHED. COPYRIGHT 2005 | THIS DRAWING IS UNPUBLISHED. COPYRIGHT 2005 RELEASED FOR PUBLICATION NOV .2005. LOC ALL RIGHTS RESERVED. BY TYCO ELECTRONICS CORPORATION. DIST REVISIONS B LTR DESCRIPTION FIRST REVISION D CODE TYCO PRODUCT CODE VALUE, TOL, DATE CODE DATE OWN APVD 04NOV05 DK |
OCR Scan | ||||
| nissei | 44 NISSEI NISSEI PART NUMBER CODE SYSTEM (1) (2) Type (3) Lead Internal con fig use uration (4) Rated voltage (5) CapacitanceCapacitance tolerance value Model Code (Standard "0000") (6) Lead Dimensions Packing Mode code *2 (2) Lead configuration code Code |
Original | ||||
| avr034 | AVR034: Mixing C and Assembly Code with IAR Embedded Workbench for AVR Features • Passing Variables Between C and Assembly Code Functions • Calling Assembly Code Functions from C • Calling C Functions from Assembly Code • Writing Interrupt Functions in Assembly Code |
Original | ||||
| SST89C5x to SST89E/V5xRD and SST89E/V5xRD2 Code | SST89C5x to SST89E/V5xRD and SST89E/V5xRD2 Code Conversion Guide Application Note December 2004 SST89C5x to SST89E/V5xRD and SST89E/V5xRD2 Code Conversion Guide 1.0 INTRODUCTION This document provides guidelines to convert existing firmware code on the SST89C5x to run on the SST89E/V54RD, |
Original | ||||
|
|
||||||
| SST89C5x to SST89E/V5xRD and SST89E/V5xRD2 Code | SST89C5x to SST89E/V5xRD and SST89E/V5xRD2 Code Conversion Guide Application Note December 2004 SST89C5x to SST89E/V5xRD and SST89E/V5xRD2 Code Conversion Guide 1.0 INTRODUCTION This document provides guidelines to convert existing firmware code on the SST89C5x to run on the SST89E/V54RD, |
Original | ||||
| M HCS201 KEELOQ® Code Hopping Encoder FEATURES | M HCS201 KEELOQ® Code Hopping Encoder FEATURES Security Programmable 28-bit serial number Programmable 64-bit encryption key Each transmission is unique 66-bit transmission code length 32-bit hopping code 34-bit fixed code (28-bit serial number, 4-bit button code, 2-bit status) |
Original | ||||
| hcs201 | HCS201 KEELOQ® Code Hopping Encoder FEATURES Security Programmable 28-bit serial number Programmable 64-bit encryption key Each transmission is unique 66-bit transmission code length 32-bit hopping code 34-bit fixed code (28-bit serial number, 4-bit button code, 2-bit status) |
Original | ||||
| ht6p26 | HT6P26 224 OTP Rolling Encoder Features • Security – 60-bit transmission code – Each transmission code is unique – Programmable 24-bit customer code – 56-bit rolling code, 4-bit data code – Anti-scanning – Anti-grabbing |
Original | ||||
| ht6p27 | HT6P27 224 Programmable Rolling Encoder Features • Operating voltage: 6V~12V Low standby current Security – 60-bit transmission code – Each transmission code is unique – Programrnable 24-bit customer code – 56-bit rolling code, 4-bit data code |
Original | ||||
| ht6p26 | 2 24 HT6P26 OTP Rolling Encoder Features • Operating voltage: 2.4V~12V Low standby current Security – 60-bit transmission code – Each transmission code is unique – Programmable 24-bit customer code – 56-bit rolling code, 4-bit data code |
Original | ||||
| bar code reader | Bar Code Reader of-seven code using two bars and two spaces to describe 20 unique patterns. These 20 patterns encode the ten numbers with both odd and even parity. The patterns are shown in Figure 2. Introduction The Universal Product Code was first implemented by |
Original | ||||
| bar code reader | Bar Code Reader of-seven code using two bars and two spaces to describe 20 unique patterns. These 20 patterns encode the ten numbers with both odd and even parity. The patterns are shown in Figure 2. Introduction The Universal Product Code was first implemented by |
Original | ||||