flat panel 32", power supply
Abstract: MDEL556CID2
Contextual Info: features / Benefits p Rated for use in Class I, Div. 2 hazardous 556 Series Class I, Div. 2 Panel Mount Indicators for 1” Mounting Hole Watertight - NEMA4X IP66 locations p Safety standards - UL and NEMA p Tamperproof / Designed for high durability p Long life, lasting up to 100k hours
|
Original
|
catalogs/indication/mdel556cid2mdel556cid2flat panel 32", power supply |
PDF
|
wpc4c3hflgc
Abstract: CSA22 wpc4
Contextual Info: The Dialight SafeSite Wallpack / Bulkhead luminaire with its low profile, rugged design ensures long life and high reliability for a wide variety of Class I, Div 2, Class II, Div 2 applications. Offered in 11 Watt and 22 Watt versions, it is ideally suited for oil platforms, explosive environments, mills,
|
Original
|
catalogs/illumination/mdexsswpchzc001mdexsswpchzc001wpc4c3hflgccsa22+1wpc4
|
PDF
|
392 t4a
Abstract: T4A 392 UL1598 HZC-02-150-1111-201
Contextual Info: HAZARDOUS LOCATION FEATURES / BENEFITS SAFESITE SERIES LED WHITE DOWNLIGHT Class I , Div 2, Groups A, B, C, D hazardous environments T4A rated Class II , Div 2, Groups F, G hazardous environments T4A rated HZC-02-150-1111-201 180º beam HZC-02-150-1111-301 (360º beam)
|
Original
|
hzc-02-150-1111-201hzc-02-150-1111-301hzc-3003hzc-3001+4mdtfhzcacs001392 t4at4a 392ul1598
|
PDF
|
c1d2
Abstract: T6,3 H 250V fuse
Contextual Info: Data Sheet Class 1 Div 2 approved fuse terminal WSI 4/2 NEW The WSI 4/2 fuse terminal is used for 1 ¼ ” x ¼ ” f u s e s a n d i s t h e i n d u s t r y ’s first 1¼” x ¼” Class 1 Division 2 a p p ro v e d D I N r a i l m o u n t e d f u s e t e r m i n a l . T h e W S I 4 / 2 o ff e r s a l o w
|
Original
|
0-250v10-pole5x100wew-35/2+2c1d2t6,3 h 250v fuse
|
PDF
|
Square D 20 amp breaker
Abstract: Cutler-Hammer fdb Cutler-Hammer 225 amp circuit breaker tfk 223 TFK 148 FLB362-TT70-3 FLB140-WT20-2 FLB141-TT40-3 FLB267-WT125-2 FLB174-DT100-2
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRTEST06-3375-0 Name: 3C-375 100: DATE: JAN 19 2006 Time: 6:18:48 PM Operator: GK COLOR: CMYK FLB Circuit Breakers and Enclosures TCP: 15001 Cl. I, Div. 1 & 2, Groups C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G
|
Original
|
sys19crtest06-3375-03c-375flb267-wt200-2+16flb267-wt225-2flb267-wt125-3flb267-wt150-3flb267-wt175-3flb267-wt200-3flb267-wt225-3square d 20 amp breakercutler-hammer fdbcutler-hammer 225 amp circuit breakertfk 223tfk 148flb362-tt70-3flb140-wt20-2flb141-tt40-3flb267-wt125-2flb174-dt100-2
|
PDF
|
CROUSE-HINDS NIPPLES
Abstract: EDSCM21 EDSCM32 EDSCM33 CROUSE-HINDS CPS
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0392-2 Name: 4C-392 4C 100: DATE: JAN 19 2006 Time: 5:22:19 PM Operator: RB COLOR: CMYK TCP: 15001 Cl. I, Div. 1, Groups C,Dɍ Cl. I, Div. 2, Groups B,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G
|
Original
|
sys19crmain06-0392-24c-392edscm21+7edscm62edscm32edscm63edscm3366008comcrouse-hinds nipplescrouse-hinds cps
|
PDF
|
|
Contextual Info: 8.5" connecting the flow of global resources S ER V IN G T H E P ET R O L EU M AN D C H EM IC A L M A R K ET S • instrumentation cables • power cables • control cables • fiber optic cables FILE NAME: DESCRIPTION: RGI Design, Inc. 2245 Gilbert Avenue
|
Original
|
ins-0045-r0605 |
PDF
|
MAX5922
Abstract: MAX5922AEUI MAX5922BEUI MAX5922CEUI collision avoidance "power injector"
Contextual Info: 19-2708; Rev 0; 4/03 +48V, Single-Port Network Power Switch For Power-Over-LAN The MAX5922 features a programmable undervoltage lockout UVLO that keeps the device in shutdown until the input voltage exceeds a certain threshold, set to 38V (MAX5922A) or 28V (MAX5922B/C) internally. After successfully discovering and classifying a PD, the MAX5922
|
Original
|
max5922max5922amax5922b/cmax5922aeui+4max5922beuimax5922ceuicollision avoidancepower injector
|
PDF
|
EFS21524
Abstract: name running led lights EFS31524 s635 Ignition Transformer PILOT LIGHT transformer 110-220 S111 S153 S300
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0428-6 Name: 5C-428 5C 100: DATE: JAN 19 2006 Time: 5:25:03 PM Operator: GK COLOR: CMYK Dimensions Pg. 430 Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from
|
Original
|
sys19crmain06-0428-65c-428efs31524-+16efsc11524-efsc21524-efsc31524-efs1561efs1561-j1-j3efs11561-efs21524name running led lightsefs31524s635ignition transformerpilot lighttransformer 110-220s111s153s300
|
PDF
|
IEC 68-2-6
Abstract: LCD 4 X 20 profibus dp rs232 lcd 2 x 16 GKWIN programming software with English manual LCD 1604 gk 10 GK05 FP10SH Graphics LCD 320 x 240 mono 3.5"
Contextual Info: Panel type Display type Display Method of representation Display size Text height mm Display contrast setting Back light life LEDs GK-05 GK-10 GK-20 GK-30 GK-60 GK-70 GK-90 Key Panel Key Panel Key Panel Key Panel Key Panel Key Panel Key Panel LCD STN mono (Backlight)
|
Original
|
gk-05gk-10gk-20gk-30+14gk-60gk-70gk-9016-characteriec 68-2-6lcd 4 x 20profibus dp rs232lcd 2 x 16gkwin programming software with english manuallcd 1604gk 10gk05fp10shgraphics lcd 320 x 240 mono 3.5
|
PDF
|
UL1203
Abstract: Cutler-Hammer transformer 2 point starters Cutler-Hammer 6-1-3 Cutler-Hammer contactor FTPS100 SPACE HEATER FVNR nema 1 allen bradley to Cutler-Hammer FTPS200
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0343-1 Name: 2C-343 100: DATE: JAN 19 2006 Time: 5:18:14 PM Operator: RB EBMS Magnetic Line Starters and Enclosures Application: Spectrum EBM TM hinged cover motor control enclosures are used: ɀ For general motor control – indoors or
|
Original
|
sys19crmain06-0343-12c-343desire00+1166008comul1203cutler-hammer transformer2 point starterscutler-hammer 6-1-3cutler-hammer contactorftps100space heaterfvnr nema 1allen bradley to cutler-hammerftps200
|
PDF
|
EZD5
Abstract: EYD16 EYD86 EYD116 EYD51 EYD616 EYD21 CROUSE-HINDS NIPPLES EYD26 EYD101
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0186-4 Name: 8F-186 8F 100: DATE: JAN 19 2006 Time: 5:07:54 PM Operator: JB Condulet Sealing Fittings With Drains Size Ranges: EYD drain and EZD drain and inspection sealing fittings: ɀ restrict the passage of gases, vapors or
|
Original
|
sys19crmain06-0186-48f-186requir001+16ezd111ezd211ezd311ezd411ezd511ezd611ezd5eyd16eyd86eyd116eyd51eyd616eyd21crouse-hinds nippleseyd26eyd101
|
PDF
|
EDS21473
Abstract: EDS22868 EDS32868 EDSC21473 s635 EDS21473-J1 Ignition Transformer PILOT LIGHT EDS31473 S111
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0428-6 Name: 5C-428 5C 100: DATE: JAN 19 2006 Time: 5:25:03 PM Operator: GK COLOR: CMYK Dimensions Pg. 430 Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from
|
Original
|
sys19crmain06-0428-65c-428eds11473-j1-gb+1166008comeds21473eds22868eds32868edsc21473s635eds21473-j1ignition transformerpilot lighteds31473s111
|
PDF
|
10D3
Contextual Info: ® INNOVATION and EXCELLENCE Single Output LSN D3 Models Non-Isolated, 3.3VIN, 1-2.5VOUT 10 Amp DC/DC’s in SIP Packages Features • Industry-standard SIP pinout ■ Shorter 2.0" vs. 2.5" package length ■ 3.0-3.6V input range ■ 1/1.2/1.5/1.8/2/2.5V outputs @ 10 Amps
|
Original
|
300khz10mvp-pul/iec/en6095010d3 |
PDF
|
|
|
dp20468
Abstract: EPC605-2042 tfk 513 CROUSE-HINDS EPC EPC61042-WT90-3 EPC604-2042-WT225-3 EPC605-2042-TT200-3 EPC66042-WT100-3 EPC604-2042-WT200-3 EPC46042-TT50-3
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1056-2 Name: 4P-1056 4P 100: DATE: JAN 19 2006 Time: 6:11:31 PM Operator: RB COLOR: CMYK APJ/NPJɍɍ and DP Arktite Plugs Application: Standard Finishes: ɀ The EPC interlock receptacle is designed for use as a service outlet for portable
|
Original
|
sys19crmain06-1056-24p-105666008com+10dp20468epc605-2042tfk 513crouse-hinds epcepc61042-wt90-3epc604-2042-wt225-3epc605-2042-tt200-3epc66042-wt100-3epc604-2042-wt200-3epc46042-tt50-3
|
PDF
|
"power sourcing equipment"
Contextual Info: TPS2384 SLUS634A − NOVEMBER 2004 − REVISED DECEMBER 2004 QUAD INTEGRATED POWER SOURCING EQUIPMENT POWER MANAGER APPLICATIONS D Ethernet Enterprise Switches D Ethernet Hubs D SOHO Hubs D Ethernet Mid-Spans D PSE Injectors FEATURES D Quad-Port Power Management With
|
Original
|
tps2384slus634a15-bit400-khz+1power sourcing equipment
|
PDF
|
LBH60
Abstract: CROUSE-HINDS LBY LBH90 LBH20 LBY25 LBH40 LBH condulet LBH80 LBY35 ET328
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0058-0 Name: 4F-58 4F 100: DATE: JAN 19 2006 Time: 4:59:06 PM Operator: CP COLOR: CMYK Condulet Conduit Outlet Bodies, Elbows and Tees Application: Standard Materials: LBH conduit outlet bodies are installed in hazardous areas to:
|
Original
|
sys19crmain06-0058-04f-58lbh60+9crouse-hinds lbylbh90lbh20lby25lbh40lbh conduletlbh80lby35et328
|
PDF
|
UL1203
Abstract: Cutler-Hammer Cutler-Hammer line starter Cutler-Hammer advantage cutler hammer overload ratings chart nema 23 STARTER CUTLER HAMMER EBMS4FD-W6413-E EBMS EBMS2FA-W6413-E
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0347-3 Name: 2C-347 DATE: JAN 19 2006 Time: 5:19:23 PM Operator: RB COLOR: CMYK Cl. I, Div. 1 & 2, Groups B,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,3R,4‡,7BCD,9EFG,12
|
Original
|
sys19crmain06-0347-32c-34766008com+10ul1203cutler-hammercutler-hammer line startercutler-hammer advantagecutler hammer overload ratings chartnema 23starter cutler hammerebms4fd-w6413-eebmsebms2fa-w6413-e
|
PDF
|
|
Contextual Info: TPS2384 SLUS634A − NOVEMBER 2004 − REVISED DECEMBER 2004 QUAD INTEGRATED POWER SOURCING EQUIPMENT POWER MANAGER APPLICATIONS D Ethernet Enterprise Switches D Ethernet Hubs D SOHO Hubs D Ethernet Mid-Spans D PSE Injectors FEATURES D Quad-Port Power Management With
|
Original
|
tps2384slus634a15-bit |
PDF
|
ID SERIES Mar 01, 2005
Abstract: "power sourcing equipment"
Contextual Info: TPS2384 SLUS634A − NOVEMBER 2004 − REVISED DECEMBER 2004 QUAD INTEGRATED POWER SOURCING EQUIPMENT POWER MANAGER APPLICATIONS D Ethernet Enterprise Switches D Ethernet Hubs D SOHO Hubs D Ethernet Mid-Spans D PSE Injectors FEATURES D Quad-Port Power Management With
|
Original
|
tps2384slus634a15-bit400-khz+2id series mar 01, 2005power sourcing equipment
|
PDF
|
EAHC2701
Abstract: EFHC2702 EAHC2702 EAHC3702 CONDUIT EFHC3702 EAHC3701 EAHC2601 EFHC3701
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0906-2 Name: 8L-906 8L 100: DATE: JAN 19 2006 Time: 6:00:44 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups A*, B*, C, D Cl. II, Div. 1, Groups E, F, G
|
Original
|
sys19crmain06-0906-28l-906eahc2701+10eahc2702eahc3701eahc3702eahc2601eahc2602eahc3601efhc2702conduitefhc3702efhc3701
|
PDF
|
CI31T021BE0
Abstract: CP-01110030 CI3103S0000 CI5105S0000 circuit diagram of 230vac to 12vdc converter CviLux cp ABC400-10XXG
Contextual Info: ABC400-10XXG Data Sheet Features • • • • • • • • • High efficiency up to 91% at 230VAC Universal AC input voltage range: 90-264 VAC Active power factor correction Over temperature, output overvoltage, overcurrent and short circuit protection
|
Original
|
abc400-10xxg230vacul/csa/en/iec60950-119-may-2011+6ci31t021be0cp-01110030ci3103s0000ci5105s0000circuit diagram of 230vac to 12vdc convertercvilux cp
|
PDF
|
|
Contextual Info: ® PRELIMINARY INNOVATION and EXCELLENCE Single Output LSN-15A D12 Models Non-Isolated, 12VIN, 1-5VOUT 15 Amp DC/DC’s in SIP Packages Features • Step-down buck regulators for new distributed 12V power architectures ■ 12V input 10-14V range ■ 1/1.2/1.5/1.8/2/2.5/3.3/5VOUT @15A
|
Original
|
lsn-15a12vin0-14v30mvp-p+2ul/iec/en60950emer356
|
PDF
|
|
Contextual Info: ® INNOVATION and EXCELLENCE Single Output LSN D12 Models Non-Isolated, 12VIN, 1-5VOUT 10 Amp DC/DC’s in SIP Packages Features • Step-down buck regulators for new distributed 12V power architectures ■ 12V input 10.8-13.2V range ■ 1/1.1/1.2/1.3/1.5/1.8/2/2.5/3.3/5VOUT @10A
|
Original
|
12vin30mvp-pul/iec/en60950 |
PDF
|