flat panel 32", power supply
Abstract: MDEL556CID2
Contextual Info: features / Benefits p Rated for use in Class I, Div. 2 hazardous 556 Series Class I, Div. 2 Panel Mount Indicators for 1” Mounting Hole Watertight - NEMA4X IP66 locations p Safety standards - UL and NEMA p Tamperproof / Designed for high durability p Long life, lasting up to 100k hours
|
Original
|
catalogs/indication/mdel556cid2mdel556cid2flat panel 32", power supply |
PDF
|
wpc4c3hflgc
Abstract: CSA22 wpc4
Contextual Info: The Dialight SafeSite Wallpack / Bulkhead luminaire with its low profile, rugged design ensures long life and high reliability for a wide variety of Class I, Div 2, Class II, Div 2 applications. Offered in 11 Watt and 22 Watt versions, it is ideally suited for oil platforms, explosive environments, mills,
|
Original
|
catalogs/illumination/mdexsswpchzc001mdexsswpchzc001wpc4c3hflgccsa22+1wpc4
|
PDF
|
392 t4a
Abstract: T4A 392 UL1598 HZC-02-150-1111-201
Contextual Info: HAZARDOUS LOCATION FEATURES / BENEFITS SAFESITE SERIES LED WHITE DOWNLIGHT Class I , Div 2, Groups A, B, C, D hazardous environments T4A rated Class II , Div 2, Groups F, G hazardous environments T4A rated HZC-02-150-1111-201 180º beam HZC-02-150-1111-301 (360º beam)
|
Original
|
hzc-02-150-1111-201hzc-02-150-1111-301hzc-3003hzc-3001+4mdtfhzcacs001392 t4at4a 392ul1598
|
PDF
|
namur NE 21
Abstract: MF740 DIN19234 kfd2-sr-ex2 la 7610
Contextual Info: A U T O M A T I O N C Transformer Isolated Barrier KFD2-SR2-Ex2.W _Output: Relay € - Dual Channel Input I EEx ia IIC Input II EEx ia IIG - Hazardous Field Circuit EEx ia MC and Class I, Div 1, Groups A-G - DC 24 V Nominal Power Supply
|
OCR Scan
|
14awgnamur ne 21mf740din19234+2kfd2-sr-ex2la 7610
|
PDF
|
Ex-94
Abstract: kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234
Contextual Info: C Transformer Isolated Barrier KFD2-SR2-Ex1.W _Output: Relay € - Single Channel Input EEx ia IIC - Hazardous Field Circuit EEx ia IIC and Class I, Div 1,Groups A-G - DC 24 V Nominal Power Supply ra 1+ - Selectable Mode of Operation
|
OCR Scan
|
14awgex-94kfd2-sr-ex1kfd2-sr2-ex1.w+3khd2-srnamur ne 21din19234
|
PDF
|
PSW12V-GS
Abstract: PSW12T-GS
Contextual Info: COMPACT, VIBRATION RESISTANT SWITCHES FOR DIVISION 1 HAZARDOUS LOCATIONS MADE IN USA PSW12 shown smaller than actual size Basic Unit 198 $ Rugged Design Shown smaller than actual size Belleville assembly Approval: UL listed, cUL certified; Class I, DIV 1 & 2, Groups ABCD;
|
Original
|
psw12psw12v-gdpsw12v-hdpsw12-cl+5psw12-mbpsw12t-ds-gndpsw12v-edpsw12v-gspsw12t-gs
|
PDF
|
1SVR423417R1000
Abstract: 1SVR423416R0000 1SVR423416R1000 1SVR423418R0000 1SVR423415R1000 1SVR423416R0100 1SVR423418R1000 1SVR423417R0000 90v AC to 24v DC 1SVR423418R3000
Contextual Info: Switching power supplies CP Range The switching power supplies CP offer many advantages in comparison to conventional supplies: • DIN-rail mount compact modules • Constant output voltage with good regulation • Low weight • cULus listet, UL 1604 class I, Div 2
|
Original
|
1svr423418r3000400hzcp-48/1svr423418r6000+14105vac/120vdc440hz115vac230vac667ma/v1svr423417r10001svr423416r00001svr423416r10001svr423418r00001svr423415r10001svr423416r01001svr423418r10001svr423417r000090v ac to 24v dc
|
PDF
|
druck ptx 610
Abstract: ptx 1000 Druck pressure sensor ptx 1000 druck dRUCK ptx 1265 druck dpi druck dpi 610 DRUCK 900 druck sensor ptx 610 DRUCK PMP
Contextual Info: PTX/PMP 1200 cd PTX/PMP 1200 SERIES Industrial Pressure Transmitters n ± 0.25% FS accuracy n NACE compatible wetted parts n Low-cost, rugged construction n Class I, Div 1, Intrinsically safe certified n Ranges from 2.5 to 10,000 psi USPTX1200 - PDS-A083 - 4/00
|
Original
|
usptx1200pds-a083druck ptx 610ptx 1000+8druck pressure sensorptx 1000 druckdruck ptx 1265druck dpidruck dpi 610druck 900 druck sensorptx 610druck pmp
|
PDF
|
|
Contextual Info: 440 / 450 Electronic Vibration Switches Datasheet OVERVIEW Metrix 440 and 450 electronic vibration switches provide economical, self-contained, single-channel vibration protection. The 440 switch is suitable for use in non-hazardous as well as Class I Div 2 hazardous areas. The 450 switch utilizes the same internal
|
Original
|
|
PDF
|
ARB102
Abstract: cushion octagon ARB1021 ARB122 ARB1221 ARB662 ARB821 grf crouse-hinds ARB62
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0901-3 Name: 8L-901 100: DATE: JAN 19 2006 Time: 6:00:08 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Div. 2, Groups A, B, C, D ARB and GS Flexible Luminaire Hangers
|
Original
|
sys19crmain06-0901-38l-901arb821+12arb1021arb1221arb10arb1266008comarb102cushionoctagonarb122arb662grf crouse-hindsarb62
|
PDF
|
GHG 511 4306 R3001
Abstract: 4407 GHG 514 7407 R0001 GHG 514 4406 R0001 GHG 511 7306 R3001 R3001 GHG 514 4407 R3001 ARRD33 GHG 514 4407 L3001 GHG 514 4406 R3001
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1070-1 Name: 5P-1070 100: DATE: JAN 19 2006 Time: 6:12:56 PM Operator: RB Hazardous Area Interlocks & Plugs ‘‘GHG’’ Series 5P COLOR: CMYK TCP: 15001 Typedriver Name: TS name Class I, Zone 1 & 2, Div. 2,
|
Original
|
sys19crmain06-1070-15p-107020/16a+1630/32a60/63a100/125achcc320chcc420chcc520ghg 511 4306 r30014407ghg 514 7407 r0001ghg 514 4406 r0001ghg 511 7306 r3001r3001ghg 514 4407 r3001arrd33ghg 514 4407 l3001ghg 514 4406 r3001
|
PDF
|
alc221
Abstract: ALC3232 ALC228 alc323 ALC324 alc32 ALC214 ALC218 ALC224 ALC321
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0898-3 Name: 8L-898 8L 100: DATE: JAN 19 2006 Time: 6:00:04 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Div. 2, Groups A, B, C, D AL Flexible Luminaire Hangers For Pendant Mount
|
Original
|
sys19crmain06-0898-38l-898alt214+16alt224alt324alt21alt22alt32alc21alc221alc3232alc228alc323alc324alc32alc214alc218alc224alc321
|
PDF
|
c1d2
Abstract: T6,3 H 250V fuse
Contextual Info: Data Sheet Class 1 Div 2 approved fuse terminal WSI 4/2 NEW The WSI 4/2 fuse terminal is used for 1 ¼ ” x ¼ ” f u s e s a n d i s t h e i n d u s t r y ’s first 1¼” x ¼” Class 1 Division 2 a p p ro v e d D I N r a i l m o u n t e d f u s e t e r m i n a l . T h e W S I 4 / 2 o ff e r s a l o w
|
Original
|
0-250v10-pole5x100wew-35/2+2c1d2t6,3 h 250v fuse
|
PDF
|
|
Contextual Info: Data sheet. CP T SNT 360W 48V 7,5A Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The powerful new line of PRO-H power supplies – with ATEX and Class I Div. 2 approvals – is designed
|
Original
|
d-32758e236157cone258476cone255651conv |
PDF
|
|
|
|
Contextual Info: Redundancy module - QUINT-DIODE/48DC/40 - 2866585 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
|
Original
|
com/us/produkte/2866585quint-diode/48dc/40quint-diode/40 |
PDF
|
EPC377
Abstract: 30eb3 Square D KAL Breaker CROUSE-HINDS EPC 40FDB EPC317-250JB-2 S784 EPC377-20FDB-3 breaker ehd EPC317-125JB-3
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0370-2 Name: 3C-370 3C 100: DATE: JAN 19 2006 Time: 5:20:53 PM Operator: GK COLOR: CMYK TCP: 15001 Cl. I, Div. 1 & 2, Groups C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,4,7CD,9EFG
|
Original
|
sys19crmain06-0370-23c-370epc317+15epc317-125jb-2epc317-150jb-2epc317-175jb-2epc317-200jb-2epc317-225jb-2epc37730eb3square d kal breakercrouse-hinds epc40fdbepc317-250jb-2s784epc377-20fdb-3breaker ehdepc317-125jb-3
|
PDF
|
EFS-218
Abstract: EFS2190 EDS2192 EFSC2190 EDSC315 EFS2184 EDS2190 efs3190 EDS3190 EFS2192
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0428-6 Name: 5C-428 5C 100: DATE: JAN 19 2006 Time: 5:25:03 PM Operator: GK COLOR: CMYK Dimensions Pg. 430 Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from
|
Original
|
sys19crmain06-0428-65c-42866008com+10efs-218efs2190eds2192efsc2190edsc315efs2184eds2190efs3190eds3190efs2192
|
PDF
|
CROUSE-HINDS NIPPLES
Abstract: EDSCM21 EDSCM32 EDSCM33 CROUSE-HINDS CPS
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0392-2 Name: 4C-392 4C 100: DATE: JAN 19 2006 Time: 5:22:19 PM Operator: RB COLOR: CMYK TCP: 15001 Cl. I, Div. 1, Groups C,Dɍ Cl. I, Div. 2, Groups B,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G
|
Original
|
sys19crmain06-0392-24c-392edscm21+7edscm62edscm32edscm63edscm3366008comcrouse-hinds nipplescrouse-hinds cps
|
PDF
|
EDS2129
Abstract: EDS3129 EDSC2129 EDSC3129 EDSC218 EFD36 EFD35 EDSC228 EDS2130 EDSC328
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0428-6 Name: 5C-428 5C 100: DATE: JAN 19 2006 Time: 5:25:03 PM Operator: GK COLOR: CMYK Dimensions Pg. 430 Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from
|
Original
|
sys19crmain06-0428-65c-428efd3691+15efd3694edsc2229edsc228edsc2223edsc2230edsc2240eds2129eds3129edsc2129edsc3129edsc218efd36efd35eds2130edsc328
|
PDF
|
CROUSE-HINDS UNF
Abstract: UNY305 UNY105 UNY205 CONDUIT UNF unf205 UNF305 UNY215 UNL215 UNY506
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0166-2 Name: 7F-166 7F 100: DATE: JAN 19 2006 Time: 5:06:30 PM Operator: RB Application: EL elbows are installed in conduit run or in box or fitting hub: ɀ to change direction in threaded rigid conduit run by 90°, or when
|
Original
|
sys19crmain06-0166-27f-16666008com+10crouse-hinds unfuny305uny105uny205conduit unfunf205unf305uny215unl215uny506
|
PDF
|
|
Contextual Info: 8.5" connecting the flow of global resources S ER V IN G T H E P ET R O L EU M AN D C H EM IC A L M A R K ET S • instrumentation cables • power cables • control cables • fiber optic cables FILE NAME: DESCRIPTION: RGI Design, Inc. 2245 Gilbert Avenue
|
Original
|
ins-0045-r0605 |
PDF
|
DSD917
Abstract: DSD919 DSD934 ENR5201 DSD921 ARROW-HART DSD925 CPS732R DSD922 PILOT LIGHT
Contextual Info: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0394-3 Name: 4C-394 100: DATE: JAN 19 2006 Time: 5:22:22 PM Operator: RB For use with EDSCM modular control device bodies listed on catalog page 392 and EDS/EDSC back boxes on page 397. Features: ɀ Large machine screws for fastening covers
|
Original
|
sys19crmain06-0394-34c-394dsd927+1166008comdsd917dsd919dsd934enr5201dsd921arrow-hartdsd925cps732rdsd922pilot light
|
PDF
|
MAX5922
Abstract: MAX5922AEUI MAX5922BEUI MAX5922CEUI collision avoidance "power injector"
Contextual Info: 19-2708; Rev 0; 4/03 +48V, Single-Port Network Power Switch For Power-Over-LAN The MAX5922 features a programmable undervoltage lockout UVLO that keeps the device in shutdown until the input voltage exceeds a certain threshold, set to 38V (MAX5922A) or 28V (MAX5922B/C) internally. After successfully discovering and classifying a PD, the MAX5922
|
Original
|
max5922max5922amax5922b/cmax5922aeui+4max5922beuimax5922ceuicollision avoidancepower injector
|
PDF
|
|
Contextual Info: 19-2708; Rev 0; 4/03 +48V, Single-Port Network Power Switch For Power-Over-LAN The MAX5922 is suitable for PSE function in both switch/router systems where the power is delivered to the load through the signal pairs, and in midspan systems where the power is delivered to the load through the
|
Original
|
max5922max5922a/cmax5922b/c |
PDF
|