Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CLAMP-ON SENSOR Search Results

    CLAMP-ON SENSOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    AV-THLIN2BNCM-005
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-005 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 5ft PDF
    CN-DSUB25PIN0-000
    Amphenol Cables on Demand Amphenol CN-DSUB25PIN0-000 D-Subminiature (DB25 Male D-Sub) Connector, 25-Position Pin Contacts, Solder-Cup Terminals PDF
    CN-DSUBHD26PN-000
    Amphenol Cables on Demand Amphenol CN-DSUBHD26PN-000 High-Density D-Subminiature (HD26 Male D-Sub) Connector, 26-Position Pin Contacts, Solder-Cup Terminals PDF
    CO-058BNCRBNC-010
    Amphenol Cables on Demand Amphenol CO-058BNCRBNC-010 BNC Male to BNC Right Angle Male (RG58) 50 Ohm Coaxial Cable Assembly 10ft PDF
    CO-058BNCX200-012
    Amphenol Cables on Demand Amphenol CO-058BNCX200-012 BNC Male to BNC Male (RG58) 50 Ohm Coaxial Cable Assembly 12ft PDF

    CLAMP-ON SENSOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    6F22 9V BATTERY

    Abstract: NEDA 1604 battery 6f22 APPA 39 Current clamp APPA 39 Battery Neda 1604 appa NEDA 1604 6F22 datasheet APPA-39R AC voltage transducer digital AC clamp meter
    Contextual Info: APPA 30 Series The State-of-the-Art Clamp-On Measuring Instruments AC CURRENT TRANSDUCER AC/DC CURRENT TRANSDUCER AC CURRENT/VOLTAGE/RESISTANCE CLAMP METER AC/DC CURRENT CLAMP METER AC/DC CURRENT CLAMP METER APPA 30 APPA 30R True-RMS reading 4000 count digital resolution


    Original
    106x240x4066x192x276f22 9v batteryneda 1604 battery 6f22+8appa 39current clamp appa 39battery neda 1604appaneda 1604 6f22 datasheetappa-39rac voltage transducerdigital ac clamp meter PDF

    QAP21

    Abstract: weight sensor 0 to 100 kg Siemens temperature sensor siemens building technologies siemens hvac siemens air temperature sensors hvac ambient temperature sensor lg-ni 1000
    Contextual Info: 1 1832P02 832 Cable temperature sensor QAP21.3. Series C Use The sensors are for use in heating, ventilating and air conditioning plants to acquire the temperature. It is for use with the corresponding accessories as a: • clamp-on sensor for pipework • clamp-on sensor for solar collectors


    Original
    1832p02qap21ce1n1832e1832g01+91832m041832m03weight sensor 0 to 100 kgsiemens temperature sensorsiemens building technologiessiemens hvacsiemens air temperature sensorshvac ambient temperature sensorlg-ni 1000 PDF

    Contextual Info: Clamp-on type AC Current Sensors C-CT series To construct new energy management system and contribute to the promotion of energy conservation. conservation RoHS Compliant Clamp-on type AC Current Sensors C-CT series C-CT-24 C-CT-6 C-CT-16 C-CT-10 Features


    Original
    c-ct-24c-ct-16c-ct-10ul-94v-0+5awg24200mmawg22150mm170gs PDF

    under ground cable fault distance locator

    Abstract: underground LH41A distance measurement using ir IR712 ir transmitter and receiver sensor IR720 comparison between infrared and bluetooth IR receiver 58
    Contextual Info: 43-2012:QuarkCatalogTempNew 8/13/12 9:20 AM Page 43 1 Clamp Meters, Misc. Analog Clamp Meter — RS-3 PRO Digital AC/DC Clamp-On Multimeters Precise Low Current Measurement Measure AC and DC Current Into the Low Milliamps, 1 mA Resolution Auto Zero DC for Correct Measurement Every Time


    Original
    lh41air-750ir-710ir-712+10ir-720ir-730under ground cable fault distance locatorundergrounddistance measurement using irir712ir transmitter and receiver sensorir720comparison between infrared and bluetoothir receiver 58 PDF

    SPRING

    Contextual Info: Feed-Through & Multi-Connection Spring Clamp FEED-THROUGH CSC2.5T These terminal blocks offer a time saving alternative to the popular screw clamp connection. They can be mounted on 35 mm DIN rails. Insulated push-in type jumpers offer a quick and shock proof solution for most


    Original
    e220514spring PDF

    SMP-04V-BC

    Abstract: SMP-06V-BC
    Contextual Info: Mounting and Handling Suggestions .114 .047 TOP CLAMP AREA .125 .075 .037R .210″ CELL .021 Figure 1. BOTTOM CLAMP AREA Leads should be securely clamped top and bottom in the area between the plastic body and the form being sure that no stress is being put on plastic


    Original
    smp-04v-bcsmp-06v-bcshf-01t-0 PDF

    SMP-02V-BC

    Abstract: PVC 90A material clamp meter circuit diagram 90-Amp PVC 90A material datasheet AWG18 AWG22 TU10P-90A clamp-on sensor
    Contextual Info: Topstek AC Current Sensor TU10P-90A AC Current Transducers TU10P-90A Features and Applications iAccurate AC current monitoring/measuring device iFast clamp-on application on existing switchboard wire iExcellent linearity of the output voltage over a wide input range


    Original
    tu10p-90a90amp120arms150khz+1160sec500vdcul94v0awg22awg18smp-02v-bcpvc 90a materialclamp meter circuit diagram90-amppvc 90a material datasheetclamp-on sensor PDF

    SMP-06V-BC

    Abstract: SMP-04V-BC YC12
    Contextual Info: Mounting and Handling Suggestions .114 .047 TOP CLAMP AREA .125 .075 .037R .210″ BOTTOM CLAMP AREA Leads should be securely clamped top and bottom in the area between the plastic body and the form being sure that no stress is being put on plastic body. The area between dotted lines


    Original
    smp-04v-bcsmp-06v-bcshf-01t-0yc12 PDF

    honeywell m 944 r

    Abstract: Sensotec 060 Sensotec transducer Sensotec induction power supply 300 va ips diagram 008803-2-EN
    Contextual Info: Model 9300 Clamp-on Rotary Torque Transducer System DESCRIPTION The Series 9300 Torsionometer is ideal for measuring torque on ing beam lengths to generate the specific output to the on-board machinery where little down time can be afforded. The quick in-


    Original
    008803-2-enhoneywell m 944 rsensotec 060sensotec transducer+3sensotecinduction power supply300 va ips diagram PDF

    SMP-02V-BC

    Abstract: clamp meter circuit diagram AWG22 UL94V0 PVC TU24P-250A AWG18 clamp-on 1000v 250A connector
    Contextual Info: Topstek AC Current Sensor TU24P-250A TU24P-250A Features and Applications iAccurate AC current monitoring/measuring device iFast clamp-on application on existing switchboard wire iExcellent linearity of the output voltage over a wide input range iFerrite core ensuring fast response time and low phase lag


    Original
    tu24p-250a250amp50marms250arms+1250hz/60hz360arms100khz60sec500vdcsmp-02v-bcclamp meter circuit diagramawg22ul94v0 pvcawg18clamp-on1000v 250a connector PDF

    Siemens PT100 temperature sensor

    Abstract: PT 2000 temperature sensor PT100 temperature sensor class B PT100 DIN PT100 temperature sensor water pt 100 sensor technical data siemens PT100 temperature sensor long sensing element PT100 surface temperature sensor signal conditioning circuit for pt100 pt100 siemens
    Contextual Info: 1 804 Clamp-on temperature sensor QAD100.1 Use The sensor is used for acquiring the medium temperature on the surface of pipes e.g. the heating water in heating, ventilation or air conditioning plants . It is designed for use in connection with automation equipment, display and logging


    Original
    qad100pt1001804g011804m01+11cm1n1804ensiemens pt100 temperature sensorpt 2000 temperature sensorpt100 temperature sensor class bpt100 dinpt100 temperature sensor waterpt 100 sensor technical data siemenspt100 temperature sensor long sensing elementpt100 surface temperature sensorsignal conditioning circuit for pt100pt100 siemens PDF

    clamp meter circuit diagram

    Abstract: AWG18 AWG22 TU16P-150A
    Contextual Info: Topstek AC Current Sensor TU16P-150A TU16P-150A Features and Applications iAccurate AC current monitoring/measuring device iFast clamp-on application on existing switchboard wire iExcellent linearity of the output voltage over a wide input range iFerrite core ensuring fast response time and low phase lag


    Original
    tu16p-150a150amp10marms150arms+850hz/60hz300arms150khz60sec500vdcclamp meter circuit diagramawg18awg22 PDF

    LG-Ni1000

    Abstract: Siemens Ni1000 temperature sensor Ni1000 temperature sensor Resistance characteristic Ni1000 ni1000 LG-Ni1000 connection QAD26 landis staefa 1802M01 1802G01
    Contextual Info: 1 Clamp-on Temperature Sensor 802 QAD26.220 Use Heating, ventilation, air conditioning and refrigeration plant. Acquisition of the medium temperature in pipes from −35 to +90 °C to provide measurement, limitation, compensation, or control. Ordering and


    Original
    qad26lg-ni1000ni10001802g01+71802m01cm1n1802esiemens ni1000 temperature sensorni1000 temperature sensorresistance characteristic ni1000lg-ni1000 connectionlandis staefa PDF

    UL1430

    Contextual Info: www.hamlin.com 59036 Clamp Sensor Features and Benefits Features Benefits Applications • SSensor with integral clamping feature • Suitable for mounting on 15mm ø pipework • Choice of contacts • Choice of connector • Customer defined cable length


    Original
    ul1430 PDF

    XHP-2

    Contextual Info: Farnell Codes: 554 0707- 0719-0720-0732 www.hamlin.com 59036 Clamp Sensor Features and Benefits Features Benefits Applications S with integral clamping • Sensor feature • Suitable for mounting on 15mm ø pipework • Choice of contacts • Choice of connector


    Original
    xhp-2 PDF

    BTS555 green

    Abstract: BB 555 BTS555 PG-TO218-5-146 BTS555 E3146
    Contextual Info: PROFET Data Sheet BTS555 Smart Highside High Current Power Switch Product Summary Overvoltage protection Output clamp Operating voltage On-state resistance Load current ISO Short circuit current limitation Current sense ratio Reversave • Reverse battery protection by self turn on of


    Original
    bts5552010-june-01bts555 greenbb 555+2pg-to218-5-146bts555 e3146 PDF

    BTS550P

    Abstract: BTS 550P Q67060-S6952A3 650P q67060s6952a3
    Contextual Info: PROFET Data Sheet BTS550P Smart Highside High Current Power Switch Reverse Save Product Summary Overvoltage protection Output clamp Operating voltage On-state resistance Load current ISO Short circuit current limitation Current sense ratio • Reverse battery protection by self turn on of


    Original
    bts550p2000-mar-24bts 550pq67060-s6952a3+2650pq67060s6952a3 PDF

    BB 555

    Abstract: BTS550P LOGIC CHIP 650P BTS550P Q67060-S6952A3
    Contextual Info: PROFET Data Sheet BTS550P Smart Highside High Current Power Switch Product Summary Overvoltage protection Output clamp Operating voltage On-state resistance Load current ISO Short circuit current limitation Current sense ratio Reversave • Reverse battery protection by self turn on of


    Original
    bts550p2003-oct-01bb 555bts550p logic chip+2650pq67060-s6952a3 PDF

    BTS660P

    Abstract: s6309 Q67060-S6309 E3180A bts660 E3180 transistor SMD t
    Contextual Info: PROFET Data Sheet BTS660P Smart Highside High Current Power Switch Product Summary Overvoltage protection Output clamp Operating voltage On-state resistance Load current ISO Short circuit current limitation Current sense ratio Reversave • Reverse battery protection by self turn on of


    Original
    bts660p2003-oct-01s6309q67060-s6309+4e3180abts660e3180transistor smd t PDF

    Contextual Info: INTEGRATED CIRCUITS DAT SAA1305T On/off logic IC Product specification Supersedes data of 1998 Sep 04 2004 Jan 15 Philips Semiconductors Product specification On/off logic IC SAA1305T FEATURES • 8 accurate Schmitt trigger inputs with clamp circuits • Very low quiescent current


    Original
    saa1305tsca76r32/02/pp32 PDF

    Contextual Info: MP5010A 3V-18V, 1A-5A Programmable-CurrentLimit Switch with Over-Voltage Clamp The Future of Analog IC Technology DESCRIPTION The MP5010A is a protection device designed to protect circuitry on the output source from transients on the input (VCC). It also protects the


    Original
    mp5010av-18vmo-229 PDF

    Contextual Info: S E N S O R S May 2014 Clamp Type AC Current Sensors For energy management systems CCT series CCT323047 CCT261631 2/7 S E N S O R S An attention matter on use Please read this specifications before using this product by all means. An attention matter on security


    Original
    cct323047cct261631quakep60hz50/60hz+5spal-001t-p0palr-02vfawg22160mmac2200v PDF

    Contextual Info: S E N S O R S April 2014 Clamp Type AC Current Sensors For Energy Management Systems CCT series CCT323047 CCT261631 2/7 S E N S O R S An attention matter on use Please read this specifications before using this product by all means. An attention matter on security


    Original
    cct323047cct261631quak60hz50/60hz+5spal-001t-p0palr-02vfawg22160mmac2200v PDF

    PG-TO218-5-146

    Abstract: diode zd 22 BTS550P-E3146 ZD 6v8 PG-TO218-5
    Contextual Info: PROFET Data Sheet BTS550 Smart Highside High Current Power Switch Product Summary Overvoltage protection Output clamp Operating voltage On-state resistance Load current ISO Short circuit current limitation Current sense ratio Reversave • Reverse battery protection by self turn on of


    Original
    bts5502010-june-01726-bts550pe3146bts550p+6e3146pg-to218-5-146diode zd 22bts550p-e3146zd 6v8pg-to218-5 PDF