CHROMEL ALUMEL Search Results
CHROMEL ALUMEL Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
contacts 8500-697
Abstract: 8500-9573 8500-697
|
Original |
8500-e contacts 8500-697 8500-9573 8500-697 | |
8500-9573
Abstract: 8500-781 contacts 8500-697
|
Original |
||
Contextual Info: Pomona Model 6371 Extended Length Temperature Probe FEATURES: • Small diameter for application where space is not available. • Use with extension cable 6379. • Extended temperature measurement range. MATERIALS: Thermocouple – “K” Type, Chromel/Alumel wire. |
Original |
30VAC/60VDC. 99C\D6371 | |
d6376
Abstract: chromel fatigue in 6376 chromel alumel
|
Original |
30VAC/60VDC. Goldberg\FlukeDataSheet\d6376 d6376 chromel fatigue in 6376 chromel alumel | |
ANSI MC96.1
Abstract: 55A8000-AWG British standard bs 159 ANSI MC96.1 wire size AWG MIL-STD-687 Thermocouple color codes cable 55A8001-AWG CTC-0015 alumel chromel
|
Original |
CTC-0015 55A8001-AWG 55A8000-AWG CTC-0015-24-* CTC-0015-22-* CTC-0015-20-* CTC-0015-18-* CTC-0015-16-* MIL-STD-681. MIL-STD-681 ANSI MC96.1 55A8000-AWG British standard bs 159 ANSI MC96.1 wire size AWG MIL-STD-687 Thermocouple color codes cable 55A8001-AWG CTC-0015 alumel chromel | |
T12-7900-510
Abstract: T12-4926-110 t12-8500-510
|
Original |
MIL-DTL-5015 MIL-DTL-5015 T12-7900-510 T12-4926-110 t12-8500-510 | |
MS27488-20
Abstract: MS27488-22
|
Original |
10-70506-10S MS27488-16 MS27488-20 MS27488-22 MS27488-12 MS27488-8 T3-4008-59P MS27488-20 MS27488-22 | |
ANSI MC96.1
Abstract: WTC-0013 Thermocouple color codes cable ANSI MC96.1 TYPE R THERMOCOUPLE WTC-0014 MIL-STD-687 chromel alumel Thermocouple temperature color codes cable CTC-0039-16-1
|
Original |
CTC-0039 WTC-0013 WTC-0014 lbs/1000 CTC-0039-22-* CTC-0039-20-* CTC-0039-18-* CTC-0039-16-* MIL-STD-681. MIL-STD-681 ANSI MC96.1 WTC-0013 Thermocouple color codes cable ANSI MC96.1 TYPE R THERMOCOUPLE WTC-0014 MIL-STD-687 chromel alumel Thermocouple temperature color codes cable CTC-0039-16-1 | |
Contextual Info: JT/LJT — thermocouple contacts, plastic protection caps, sealing plugs THERMOCOUPLE CONTACTS Contact Size 20 Material JT/LJT Pins JT Sockets LJT Sockets Chromel 10-407862-310 10-407863-310 10-407236-310 Alumel 10-407862-320 10-407863-320 10-407865-320 Iron |
Original |
MS27488-16 MS27488-20 MS27488-22 MS27488-12 MS27488-8 T3-4008-59P | |
Contextual Info: JT/LJT — thermocouple contacts, plastic protection caps, sealing plugs THERMOCOUPLE CONTACTS Contact Size JT/LJT Pins JT Sockets LJT Sockets Chromel 10-407862-310 10-407863-310 10-407236-310 Alumel 10-407862-320 10-407863-320 10-407865-320 Iron 10-407862-335 |
Original |
T3-4008-59P MS27488-16 MS27488-20 MS27488-22 MS27488-8 10-70506-10S | |
R12-7950-110
Abstract: R12-3613-110 R12-3600-110 R12-7900-110
|
Original |
MIL-DTL-5015 MIL-C-5015 R12-2500-110 R12-3632-110 R12-3608-110 MIL-DTL-5015 R12-7950-110 R12-3613-110 R12-3600-110 R12-7900-110 | |
Contextual Info: Indication method No indication Temperature Controller Control mode ON/OFF Proportional P E5C2 Input Output Input/ Thermo- K (CA) stan- couple Chromel dard vs. alumel scale (°C) Relay 0 to 200 E5C2-R20K E5C2-R40K 0 to 300 E5C2-R20K E5C2-R40K 0 to 400 E5C2-R20K |
Original |
E5C2-R20K E5C2-R40K | |
T3-4120-10R
Abstract: T3-4020-10P
|
Original |
MIL-DTL-38999, M39029/87-472 T3-4022-10P M39029/88-484 MS27488-16 MS27488-20 MS27488-22 T3-4008-59P T3-4120-10R T3-4020-10P | |
Contextual Info: DTM 995 LCD Type K Thermocouple Indicator This meter will give a direct reading in °C from a K type chromel-alumel thermocouple sensor. The circuit uses a converter/amplifier which has Cold Junction Compensation. Calibration is by two 20-turn cermet potentiometers which allow sensitive adjustment of the |
Original |
20-turn August/2002 | |
|
|||
ANSI MC96.1
Abstract: ANSI MC96.1 TYPE E ANSI MC96.1 temperature measurements thermocouple ANSI MC96.1 Type K Thermocouple Free MC96.1 ANSI MC96.1 TYPE T platinum resistance thermometer 4 wire MC96.1 ANSI MC96.1 TYPE R THERMOCOUPLE ANSI MC96.1 TYPE K THERMOCOUPLE TOLERANCES
|
Original |
||
Contextual Info: Introduction Size #23 Crimp Contacts for Series 80 High-Speed Mighty Mouse Connectors Size #23 Crimp Contacts Standard size #23 contacts accept #22 to #28 AWG wire. Choose "small bore" versions for #26 to #30 AWG wire. For thermocouple applications, specify alumel or chromel contacts. Contacts are |
Original |
M22520 K1461 | |
Contextual Info: Contacts Tools Series 80 Mighty Mouse Contacts and Tools Size #23 Crimp Contacts Size #23 Crimp Contacts A Standard size #23 contacts accept #22 to #28 AWG wire. Choose "small bore" versions for #26 to #30 AWG wire. For thermocouple applications, specify alumel or chromel contacts. Contacts are bulk |
Original |
M22520 851-0l 01-JANUARY-2010 | |
Contextual Info: DTM 995 LCD Type K Thermocouple Indicator This meter will give a direct reading in °C from a K type chromel-alumel thermocouple sensor. The circuit uses a converter/amplifier which has Cold Junction Compensation. Calibration is by two 20-turn cermet potentiometers which allow sensitive adjustment of the |
Original |
20-turn August/2002 | |
Contextual Info: Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA 25742 , Web: www.alphawire.com Customer Specification PART NO. M9240243 Construction Diameters (In) 1) Component 1 24 X 1 PAIR a)Conductor 1 20 (SOLID) AWG CHROMEL 0.032 b)Conductor 2 |
Original |
M9240243 Facin000 | |
Contextual Info: Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA 25742 , Web: www.alphawire.com Customer Specification PART NO. M9240123 Construction Diameters (In) 1) Component 1 12 X 1 PAIR a)Conductor 1 20 (SOLID) AWG CHROMEL 0.032 b)Conductor 2 |
Original |
M9240123 Facin000 | |
Contextual Info: Mighty Mouse Micro USB Series 80 Mighty Mouse Contacts and Tools Size #23 Crimp Contacts SIZE #23 CRIMP CONTACTS Standard size #23 contacts accept #22 to #28 AWG wire. Choose "small bore" versions for #26 to #30 AWG wire. For thermocouple applications, specify alumel or chromel contacts. Contacts are bulk |
Original |
M22520 | |
size 23 positioner part number 809-005
Abstract: 809 001 809-005 AMS-QQ-P-35 B196 B197 M22520 chromel thermocouple contacts crimp contacts alumel
|
Original |
M22520 09-065A 809-065C 809-nto 04-July-2009 size 23 positioner part number 809-005 809 001 809-005 AMS-QQ-P-35 B196 B197 chromel thermocouple contacts crimp contacts alumel | |
circuit with thermocouple application
Abstract: thermocouple connector pin thermocouple sensor thermocouple meter Amplifier type K thermocouple 0727 Cold Junction Compensation thermocouple Thermocouple circuit type t Amplifier k thermocouple
|
Original |
20-turn August/2001 circuit with thermocouple application thermocouple connector pin thermocouple sensor thermocouple meter Amplifier type K thermocouple 0727 Cold Junction Compensation thermocouple Thermocouple circuit type t Amplifier k thermocouple | |
size 23 positioner part number 809-005
Abstract: K1461 809-005 chromel A 26 AWG m81969.14.01
|
Original |
M22520 K1461 size 23 positioner part number 809-005 K1461 809-005 chromel A 26 AWG m81969.14.01 |