Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CCFL TRANSFORMER AP Search Results

    Documents mentioning CCFL TRANSFORMER AP

    Document Partial File Text Tags Type PDF
    transformer
    Maxim > App Notes > Digital Potentiometers Keywords: CCFL, cold cathode fluorescent lamp, transformer Dec 10, 2004 APPLICATION NOTE 3375 DS3984/DS3988 Transformer Turns Ratio Selection Abstract: The DS3984 and DS3988 are multichannel cold-cathode fluorescent lamp (CCFL) controllers. The key
    Original PDF
    ccfl driving inverter transformer
    INVERTER M OUTLINE/概要 1. CCFL driving inverter transformer using EE core which has a multiple secondary split winding space. 2. Narrow & low profile type CCFL driving inverter transformer designed for the back light power supply for larger LCD application.
    Original PDF
    ccfl transformer
    Document 575 CCFL Transformer For Texas Instruments TPS68000 CCFL Controller The FA2786-BL was developed specifically for the Texas Instruments TPS68000 Phase Shift Full Bridge CCFL Controller. It is designed for use in cold cathode fluorescent lamp power
    Original PDF
    ccfl transformers
    ® CCFL TRANSFORMERS GENERAL Coiltronics designs and manufactures Cold Cathode Fluorescent Lamp Inverter Transformers for use in CCFL Power Supplies. Standard product geometries are described in this Product Catalog. If your CCFL Inverter Transformer requirement is not described here, contact
    Original PDF
    inverter control ic
    CCFL inverter control IC for piezo electric transformer 圧電トランス式CCFLインバータ制御IC TK75040V DESCRIPTION The TK75040V is a CCFL (Cold Cathode Fluorescent Lamp) inverter control IC for piezo electric transformer. Its output is push-pull and
    Original PDF
    piezoelectric transformer
    Power Management Texas Instruments Incorporated Comparing magnetic and piezoelectric transformer approaches in CCFL applications By Eddy Wells Power Management Products Systems Specialist Figure 1. Typical voltage and current behavior in a CCFL 3-mm-Diameter Lamp VI Characteristics
    Original PDF
    inverter transformer
    CCFL Driving Inverter Transformer APPLICATIONS ■ Inverter units for cold cathode fluorescent lamp. 1. LCD TV 2. LCD monitor 3. Notebook computer 4. Scanner 5. Word processor 6. PDA 7. Digital still camera 8. IPC 9. Cellphone INVERTER TRANSFORMER POWER INDUCTOR
    OCR Scan PDF
    ame9001
    AME, Inc. CCFL Backlight Controller AME9001 n General Description n Pin Configuration The AME9001 controller provides a cost efficient means to drive single or multiple cold cathode fluorescent lamps (CCFL). Specifically the AME9001 drives 3 external MOSFETs that, in turn, drive a wirewound transformer
    Original PDF
    inverter transformer
    CCFL DRIVING INVERTER TRANSFORMER I SMT DC-DC CONVERTER & EL DRIVING INVERTER TRANSFORMER TOKO , « DC D C 3 > ''- ? f c c f c O E U N '< M CCFL Drivin 7 Inverter T 7 » Œ ! r « l ? Œ H ♦ (8 .3 x 10.8 x 5 m m ) M ax. (1 3 .5 x 13.5 x 5.1 m m ) M ax.
    OCR Scan PDF
    ccfl backlight
    AME, Inc. CCFL Backlight Controller AME9001 n General Description n Pin Configuration The AME9001 controller provides a cost efficient means to drive single or multiple cold cathode fluorescent lamps (CCFL). Specifically the AME9001 drives 3 external MOSFETs that, in turn, drive a wirewound transformer
    Original PDF
    ame9001
    AME, Inc. CCFL Backlight Controller AME9001 n General Description n Pin Configuration The AME9001 controller provides a cost efficient means to drive single or multiple cold cathode fluorescent lamps (CCFL). Specifically the AME9001 drives 3 external MOSFETs that, in turn, drive a wirewound transformer
    Original PDF
    max1739
    19-1755; Rev 1; 3/01 Wide Brightness Range CCFL Backlight Controllers Features ♦ Fast Response to Input Change The MAX1739/MAX1839 monitor and limit the transformer center-tap voltage when required. This ensures minimal voltage stress on the transformer, which
    Original PDF
    19-1755; Rev 1; 3/01 Wide Brightness Range CCFL
    19-1755; Rev 1; 3/01 Wide Brightness Range CCFL Backlight Controllers Features ♦ Fast Response to Input Change The MAX1739/MAX1839 monitor and limit the transformer center-tap voltage when required. This ensures minimal voltage stress on the transformer, which
    Original PDF
    ceidl369
    INVERTER CEIDL369 OUTLINE / 概要 1. The leakage transformer has a special core that allows for co-axial winding. 2. Suitable for large LCD panel, and complies to customer needs of high open voltage and high lamp wattage. 3. Inverter transformer corresponding to multiple CCFL lamps driving
    Original PDF
    INVERTER EIDL369 OUTLINE / 概要 1. The leakage
    INVERTER EIDL369 OUTLINE / 概要 1. The leakage transformer has a special core that allows for co-axial winding. 2. Suitable for large LCD panel, and complies to customer needs of high open voltage and high lamp wattage. 3. Inverter transformer corresponding to multiple CCFL lamps driving
    Original PDF
    clt4123
    Max. 8W, Medium & Large size LCD Monitors and vehicle applications 中型&大型液晶显示器 (最大8W) 和车载设备用液晶显示器 TYPE CLT4123 CLT4123 (Unit: mm) Description • Surface mount inverter transformer for CCFL driving. • Suitable as an inverter transformer for LCD backlight.
    Original PDF
    INVERTER M OUTLINE/概要 1. The leakage transformer
    INVERTER M OUTLINE/概要 1. The leakage transformer has a special core that allows for co-axial winding. 2. Suitable for large LCD panel ,and complies to customer needs of high open voltage and high lamp wattage. 3. Slim type Inverter transformer corresponding to multiple CCFL
    Original PDF
    ccfl inverter
    Frontier Electronics Corp. 667 E. COCHRAN STREET, SIMI VALLEY, CA 93065 TEL: (805) 522-9998 FAX: (805) 522-9989 E-mail: frontiersales@frontierusa.com Web: frontierusa.com CCFL Inverter Transformer—TSS1230F-01 A. Specification: Part No. Mark Suitable Frequency
    Original PDF
    ui1734
    Inverter Transformer For LCD TV UI1734 Type Features: High leakage inductance type (LK: 800mH Max.) designed for IC controlled type circuit. Low profile(8.0mm Max.). Application: Large LCD TV LCD Monitor 2-Output type, capable of driving 2 pcs CCFL Mechanical Dimension:
    Original PDF
    lcd tv
    Inverter Transformer For LCD TV EPC25/40 Type Features: Easy surface mounting and compatible with hot-air reflow soldering. Low profile(13.0mm Max.). High voltage resistant and reliable due to multi-divisible construction. Green product version. Driving 8~10 pcs CCFL.
    Original PDF
    high performance ccfl controller
    LX6512A High Performance CCFL Controller ® TM P RODUCT BRIEF DESCRIPTION The LX6512A contains safety features that limit the transformer secondary voltage and protect against fault conditions including open lamp or broken lamp, over voltage, arcing, and short-circuit fault. In
    Original PDF
    ccfl transformer
    CCFL Transformer Application Note Cold Cathode Fluorescent Lamps (CCFLs) are used to illuminate Liquid Crystal Displays (LCDs). The LCD display is used in laptop computers, gas pumps, automobiles, test equipment, PDAs and medical instruments. CCFLs are small, efficient and inexpensive. The lamp must be driven by a
    Original PDF